V. Prabhakara Rao

V. Prabhakara Rao

Auto-generated profile, based on publicly available information

V. Prabhakara Rao

Department of Chemistry Sri Venkateswara University Tirupathi-517502 Andhra Pradesh India

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
YRY. Veera Manohara Reddy
Y. Veera Manohara Reddy
VRV. Prabhakara Rao
V. Prabhakara Rao
ARAmbavaram Vijaya Bhaskar Reddy
Ambavaram Vijaya Bhaskar Reddy
MLM. Lavanya
M. Lavanya
MVM. Venu
M. Venu
Gajulapalli MadhaviGajulapalli Madhavi
Gajulapalli Madhavi

1 January 2016 in Asian Journal of Chemistry
Verified
Journal Article
Open access
VRV. Prabhakara Rao
V. Prabhakara Rao
YRY. Veera Manohara Reddy
Y. Veera Manohara Reddy
MLM. Lavanya
M. Lavanya
MVM. Venu
M. Venu
GMG. Madhavi
G. Madhavi

30 July 2016 in Chemical Science Transactions
Verified
Journal Article
Open access
PDF file
VRV. Prabhakara Rao
V. Prabhakara Rao
YRY. Veera Manohara Reddy
Y. Veera Manohara Reddy
PJP. Jeevan Jyothi
P. Jeevan Jyothi
SKS. Kiranmai
S. Kiranmai
Gajulapalli MadhaviGajulapalli Madhavi
Gajulapalli Madhavi
Uric acid (UA) detection is quite important in humans as high blood concentrations of UA called Hyperuricemia can lead to Gout, diabetes and formation of kidney stones etc. In the present work, a sensitive and selective method is presented for the voltammetric determination of UA in the presence of ascorbic acid (AA) and dopamine (DA) using a carbon paste electrode (CPE) modified with benzoic acid in 0.1 M phosphate buffer solution (PBS) of pH 7 by electropolymerisation. The obtained poly(benzoic acid) modified carbon paste electrode (PBA/CPE) showed excellent electro catalytic activity for the selective detection of UA in the presence of AA and DA and it also showed good reproducibility. Its sensitivity increased 2.33 folds for the detection of UA compared to bare carbon paste electrode (BCPE). Effect of variation of scan rate on the peak current indicated that the electrode process is both diffusion controlled and adsorption controlled. The detection limit (LOD) and quantification limit (LOQ) of the present technique were found to be 3.33×10-7 M (0.333 µM) and 1.11×10-6 M (1.11 µM) respectively for UA. pH effect suggested that equal number of protons and electrons were involved in the electrochemical oxidation of UA. The percentage of recovery of UA in real sample analysis i.e. in human urine is quite good and was found to be 100.5% using PBA/CPE. Thus, the selectivity, reproducibility and sensitivity of the PBA/CPE provide a good possibility for applying the technique in the routine analysis of selected class of electro active biomolecules.