Gajulapalli Madhavi

Prof. Gajulapalli Madhavi


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Journal of Photochemistry and Photobiology B: Biology
Verified
Journal Article
Closed access
EHE. Haritha
E. Haritha
Selvaraj Mohana RoopanSelvaraj Mohana Roopan
Selvaraj Mohana Roopan
Gajulapalli MadhaviGajulapalli Madhavi
Gajulapalli Madhavi
GEG. Elango
G. Elango
NANaif Abdullah Al-Dhabi
Naif Abdullah Al-Dhabi
MAMariadhas Valan Arasu
Mariadhas Valan Arasu

1 November 2018 in ACS Omega
Verified
Journal Article
Open access
MVManthrapudi Venu
Manthrapudi Venu
SVSada Venkateswarlu
Sada Venkateswarlu
YRY. Veera Manohara Reddy
Y. Veera Manohara Reddy
ARAnkireddy Seshadri Reddy
Ankireddy Seshadri Reddy
VGVinod Gupta
Vinod Gupta
Gajulapalli MadhaviGajulapalli Madhavi
Gajulapalli Madhavi
Because of their large surface area and conductivity, some inorganic materials have emerged as good candidates for the trace-level detection of pharmaceutical drugs. In the present work, we demonstrate the detection of an anticancer drug (regorafenib, REG) by using an electrochemical sensor based on a nanocomposite material. We synthesized a zirconia-nanoparticle-decorated reduced graphene oxide composite (ZrO2/rGO) using a one-pot hydrothermal method. Reduction of the graphene oxide supports of the Zr2+ ions with hydrazine hydrate helped in preventing the agglomeration of the zirconia nanoparticles and in obtaining an excellent electrocatalytic response of the nanostructure ZrO2/rGO-based electrochemical sensor. Structural and morphological characterization of the nanostructure ZrO2/rGO was performed using various analytical methods. A novel regorafenib (REG) electrochemical sensor was fabricated by immobilizing the as-prepared nanostructure ZrO2/rGO on to a glassy carbon electrode (GCE). The resulting ZrO2/rGO/GCE could be used for the rapid and selective determination of REG in the presence of ascorbic acid and uric acid. The ZrO2/rGO/GCE showed a linear response for the REG analysis in the dynamic range 11–343 nM, with a remarkable lower detection limit and limit of quantifications of 17 and 59 nM, respectively. The newly developed sensor was used for the accurate determination of REG in both serum samples and pharmaceutical formulations, with satisfactory results.

17 January 2018 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
YRY. Veera Manohara Reddy
Y. Veera Manohara Reddy
BSBathinapatla Sravani
Bathinapatla Sravani
TŁTeresa Łuczak
Teresa Łuczak
MOMałgorzata Osińska
Małgorzata Osińska
HMH. Maseed
H. Maseed
Gajulapalli MadhaviGajulapalli Madhavi
Gajulapalli Madhavi
In this study we report a one-step procedure for the fabrication of Pd–Ag bimetallic nanoparticles on the surface of a graphene oxide (rGO) support. A controlled reduction of Pd2+ and Ag+ ions on an rGO support was achieved by using a methyl ammonium borane reducing agent. The fabricated Pd–Ag/rGO bimetallic nanocomposites were characterized by X-ray diffraction (XRD), Transmission electron microscopy (TEM) and Fourier-transform infrared spectroscopy (FT-IR). A Pd–Ag/rGO based electrochemical sensor was fabricated by immobilizing the as-prepared Pd–Ag/rGO bimetallic nanocomposites on to a bare glassy carbon electrode (GCE). The resulting Pd–Ag/rGO/GCE electrochemical sensor was proved to be ultrasensitive and selective towards the detection of acetaminophen (APAP) in the presence of etilefrine (ET). The linear dynamic range (LDR) for the detection of APAP was found to be 1.2–30 nM with a good limit of detection (LOD) and the limit of quantification (LOQ) of 3.26 nM and 13 nM, respectively. The newly prepared Pd–Ag/rGO/GCE-modified electrode makes a good analytical tool for the accurate determination of APAP either in its pristine conditions or in the presence of both real human samples and pharmaceutical formulations. The convenient fabrication protocol shown here can be extendable to other types of bimetallic configurations for various electrochemical sensing applications.

12 September 2018 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
YRY. Veera Manohara Reddy
Y. Veera Manohara Reddy
BSBathinapatla Sravani
Bathinapatla Sravani
HMHussen Maseed
Hussen Maseed
TŁTeresa Łuczak
Teresa Łuczak
MOMałgorzata Osińska
Małgorzata Osińska
Gajulapalli MadhaviGajulapalli Madhavi
Gajulapalli Madhavi
The present report demonstrates the development of a Pt–Ni/rGO composite electrochemical sensor for the detection of dopamine.

1 December 2015 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
YRY. Veera Manohara Reddy
Y. Veera Manohara Reddy
VRV. Prabhakara Rao
V. Prabhakara Rao
ARAmbavaram Vijaya Bhaskar Reddy
Ambavaram Vijaya Bhaskar Reddy
MLM. Lavanya
M. Lavanya
MVM. Venu
M. Venu
Gajulapalli MadhaviGajulapalli Madhavi
Gajulapalli Madhavi

19 September 2023 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
HMHussen Maseed
Hussen Maseed
VYVeera Manohara Reddy Yenugu
Veera Manohara Reddy Yenugu
SDSesha SuryaBindu Devarakonda
Sesha SuryaBindu Devarakonda
SPShaikshavali Petnikota
Shaikshavali Petnikota
Gajulapalli MadhaviGajulapalli Madhavi
Gajulapalli Madhavi
VSVadali V. S. S. Srikanth
Vadali V. S. S. Srikanth