20 September 2023 in Measurement
10 May 2021 in IEEE Transactions on Instrumentation and Measurement
This article discusses the design and development of a compact frequency modulated continuous wave (FMCW) Reflectometry diagnostic instrument. The existing setup is rigid and bulky utilizing precious Tokamak lab space, lack of remote configurability option, and requires manual intervention to change control parameters. Hence, we propose a system-on-chip ( SoC )-based automated reflectometry diagnostic instrument (ARDI) to implement all the four major electronic components into a single instrument. Wherein, the analog driver is designed to generate a non-linear sweep voltage of 0-20 V in order to drive the ultrawideband voltage controlled oscillator ( VCO ). The data acquisition system (DAQ) is deployed to acquire the in-phase (I) and quadrature (Q) components of a signal at 245 mega samples per second (MSPS) with 14-bit resolution. The trigger unit operating in pattern mode at 100 MHz is responsible to trigger all the units synchronously. The data processing unit, normalizes the signal using the proposed hardware accelerator clocked at 200 MHz. The proposed normalization technique is analyzed and compared with envelope-based normalization technique. This study conveys that the proposed technique utilizes lesser hardware resources with the availability of both I and Q components, making it computationally simpler and faster. The designed ARDI can be configured and monitored remotely by developing a graphical user interface ( GUI ).
25 September 2019 in Circuits, Systems, and Signal Processing
23 April 2023 in Fusion Engineering and Design
7 October 2025 in NDT & E International
10 March 2025 in Plasma Physics and Controlled Fusion
FMCW reflectometry for measuring edge density profiles in two channels operating in 18–28 GHz and 26–40 GHz frequency ranges has been established at the Institute for Plasma Research. The reflectometer was operated in O-Mode with its horn antennae placed outside the vacuum vessel. The diagnostics were calibrated in the laboratory and also verified in-situ. A signal processing algorithm was developed to filter the noise and frequencies other than those due to the plasma. An algorithm to remove amplitude variations is used on the raw baseband signal after which the group delay is estimated using the spectrogram technique. The Bottolier-Curtet method is used for profile inversion after correcting the measured group delay for contributions to it other than plasma. First ever measurements of edge density profiles on the Aditya-U tokamak are presented which show qualitative agreement with microwave interferometer diagnostic results.