1 October 2014 in Expert Systems with Applications
23 September 2020 in SN Applied Sciences
1 December 2015 in Renewable and Sustainable Energy Reviews
31 January 2020 in IEEE Systems Journal
A novel scheme is suggested for change detection and fault classification in ac microgrids (μGs) with different operating modes. The proposed method utilizes a Teager–Kaiser energy operator based approach for analyzing the current-based signal to detect changes in the μG. The current-based signal is a summation of squared three-phase currents (SSC), measured at one end of a line in the μG. Since μGs have different operating modes, a proper signal should be defined to have some valuable signatures of the changes in different conditions. The SSC signal is constant during normal conditions of the grid-connected and islanded μG, whereas in any possible change condition experiences considerable variation. After the detection, the faulty phase is determined using three similar indices, derived from the squared currents. These indices are the ratios of squared currents for each phase with half-cycle window length, before and after the change detection. The proposed protection scheme is able to handle both operation modes of the μG. The proposed technique is evaluated in a MATLAB/Simulink simulated network and laboratory small-scaled test bench. The results confirm high accuracy and quickness of the proposed approach. Furthermore, the performance of the proposed methodology is compared with some other similar methods.
1 November 2015 in IET Generation, Transmission & Distribution
A simple technique is proposed in this study, aimed at the islanding detection of an inverter‐based distributed generation (DG). The main advantage of the proposed technique is its reliance on a simple approach for islanding detection with negligible non‐detection zone and keeping the unchanged output power quality. This work attempts to detect islanding conditions through computing the rate of change of voltage phase angle (ROCOVPA) of the point of common coupling by phase‐locked loop (PLL) in inverter controllers. Because almost all inverter systems are equipped with the PLL, its implementation for inverter‐interfaced DGs is simple and economical. Simulation results show that the durability energy of ROCOVPA is different for islanding and non‐islanding conditions. In fact, in non‐islanding condition the energy of ROCOVPA reduces to a negligible value after a certain time, but in islanding conditions it has considerable variation. The proposed method is evaluated using the conditions dictated by the IEEE 1547 and UL 1741 standards. The simulation results are presented to highlight the effectiveness of the proposed technique. In addition, the proposed method is compared with several passive and intelligent methods and it is confirmed that the proposed method has better performance and more accuracy.
1 January 2022 in Measurement