Complementary features of batteries and supercapacitors can be effectively used in a Hybrid Energy Storage System (HESS). The utilization of the HESS in Electric Vehicles (EVs) offers many advantages such as efficient regenerative braking, battery safety, and improved vehicle acceleration. In this paper, a new Regenerative Braking System (RBS) is proposed for EVs with HESS and driven by Brushless DC (BLDC) motor. During regenerative braking, the BLDC acts as a generator. Hence, using appropriate switching algorithm, the DC-link voltage is boosted and the energy is transferred to the supercapacitor or the battery through the inverter. The harvested energy can be utilized to improve the vehicle acceleration and/or keep the battery pack from deep discharging during driving uphill. In order to provide a reliable and smooth brake, braking force distribution is realized through an Artificial Neural Network (ANN). Simultaneously, the braking current is adjusted by a PI controller for constant torque braking. In order to evaluate the performance of the proposed RBS, different simulations and experiments are carried out. The results confirm high capability of the proposed RBS.
1 November 2016 in IEEE Transactions on Power Electronics
DC microgrids have some attractive characteristics, which have being investigated to utilize in future electrical power systems. However, they have several essential challenges such as limiting and interrupting fault current, which should be rectified to have a high performance DC microgrids. In this paper, an efficient DC bidirectional Fault Current Limiter and Interrupter (FCLI) based on z-source topology is proposed to overcome some of the challenges in DC microgrids. The FCLI is a multi-function device, by which power flow direction control, circuit breaking, fault current limiting and interrupting in a DC system can be handled. Analytical analysis of the FCLI is discussed in detail for different operation modes. Performance of the proposed FCLI in the different operation modes is evaluated using some simulations and experiments. The results confirm high capability of the device to realize appropriate operation in DC systems. Fast response time of fault current limitation and interruption, simple and reliable structure, and negligible conduction loss are the main features of the proposed FCLI.
18 September 2019 in IEEE Transactions on Industrial Electronics
Online accurate estimation of supercapacitor State-of-Health (SoH) and State-of-Energy (SoE) is essential to achieve efficient energy management and real-time condition monitoring in Electric Vehicle (EV) applications. In this paper, for the first time, Unscented Kalman Filter (UKF) is used for online parameter and state estimation of the supercapacitor. In the proposed method, a nonlinear state-space model of the supercapacitor is developed, which takes the capacitance variation and selfdischarge effects into account. The observability of the considered model is analytically confirmed using a graphical approach (GA). The SoH and SoE are then estimated based on the supercapacitor online identified model with the designed UKF. The proposed method provides better estimation accuracy over KF and Extended KF (EKF) algorithms since the linearization errors during the filtering process are avoided. The effectiveness of the proposed approach is demonstrated through several experiments on a laboratory testbed. An overall estimation error below 0.5% is achieved with the proposed method. In addition, Hardware-in-the-Loop (HIL) experiments are conducted and real-time feasibility of the proposed method is guaranteed.
28 July 2017 in IEEE Transactions on Industrial Electronics
Reliable operation of dc-dc converters is vital for many applications. An appropriate converter monitoring scheme is required for fault detection and adoption of effective remedial strategies. Switch faults and degradation of electrolytic capacitor account for a considerable portion of the converter failures. Although rate of diode failures is not remarkable, power switch may be damaged in case of diode fault occurrence. Furthermore, for applications in which a redundant switch is employed as a remedy, it will be also endangered by diode failures if diode fault detection has not been considered in the monitoring scheme. Therefore, diode condition monitoring improves reliability of the converter monitoring approaches. This paper presents a simple diagnosis technique for open-circuit and short-circuit faults of the switch and diode in nonisolated dc-dc converters. The technique only employs diode voltage as the detection signature. The diode voltage and gate driver signal are processed in a simple logic circuit to generate some indicators for switch and diode fault diagnosis. Basis of the technique is discussed in detail. Several experiments have been carried out on buck, boost, and buck-boost converters. The results confirm the technique capability for switch and diode fault diagnosis in less than one switching cycle.
4 April 2017 in IEEE Transactions on Power Electronics
Since most of renewable energy resources are dc type, dc microgrids find more attention in deregulated power systems for improvement of reliability and efficiency of the system. In dc microgrids, there is no zero-crossing in current and voltage; so the circuit breaking and fault current limiting are serious concerns. Conventional thyristor-based dc fault current limiters are attractive solutions for tackling this problem. However, they impose permanent interruption on the system in case of temporary fault. In this paper, a novel hybrid circuit breaker (HCB) is proposed to improve power quality of the system by adopting different limiting behaviors for permanent and temporary faults. The proposed HCB transfers load power through a mechanical circuit breaker (MCB) under normal condition. Upon fault occurrence in both sides of the HCB, the fault current is transferred from the MCB to a current limiting path incorporating a zero voltage switching (ZVS) transition mechanism. The HCB limits the fault current for a predefined duration and then interrupts the faulty feeder. In case of temporary fault, the current is returned to the MCB in ZVS. The HCB operation principle is discussed in different operation modes. Capabilities of the proposed HCB are tested and verified by different experiments carried out on a prototype.
12 October 2018 in IEEE Transactions on Power Electronics
Online monitoring is an inevitable necessity for DC-DC converters in industrial applications to achieve a fault-tolerant structure, which ensures reliable operation and prevents catastrophic failures. In this paper, a comprehensive monitoring system is proposed for non-isolated DC-DC converters. The proposed approach is mainly focused on monitoring the most prone to failure components of these converters including switching devices and capacitor. Using the proposed monitoring system, switch/diode open circuit and short circuit faults are detected in less than one switching cycle. Furthermore, online monitoring of the capacitor equivalent series resistance and switch on-state voltage as effective precursors of aging is also carried out. Finally, an inter-turn fault detection technique is presented for the converter inductor. The mentioned monitoring tasks are accomplished using only two electrical sensors (for capturing voltages across the converter diode and inductor) and two temperature sensors. The presented monitoring approach is simple, cost-effective, easy to implement, and applicable for all non-isolated DC-DC converters including buck, boost, and buck-boost converters. Performance of the monitoring system is evaluated by considering different scenarios in the experiments carried out on a laboratory prototype. The results confirm the effectiveness of the proposed system for fault diagnosis and aging monitoring in non-isolated DC-DC converters.