25 October 2021 in Applied Physics Letters
This paper presents the electrical conductivity data of copper along the gas branch of the binodal curve in the warm dense matter (WDM) regime as a function of mass density and temperature. All data are obtained using the underwater wire explosion technique, in which vaporized copper cools along the gas branch of the binodal curve during the period of current dwell after the wire explodes. Mass density and temperature are measured by fast imaging and optical spectroscopy, respectively. Combining these data with electrical measurements of the wire resistance, we obtain the conductivities of copper along the binodal curve in the WDM regime. The electrical conductivity data measured here are expected to be helpful for developing a more accurate and reliable theory of transport properties in the WDM regime.
16 March 2023 in Matter and Radiation at Extremes
We estimate the parameters of a Cu plasma generated by an X-pinch by comparing experimentally measured x-rays with synthetic data. A filtered absolute extreme ultraviolet diode array is used to measure time-resolved x-ray spectra with a spectral resolution of ∼1 keV in the energy range of 1–10 keV. The synthetic spectra of Cu plasmas with different electron temperatures, electron densities, and fast electron fractions are calculated using the FLYCHK code. For quantitative comparison with the measured spectrum, two x-ray power ratios with three different spectral ranges are calculated. We observe three x-ray bursts in X-pinch experiments with two Cu wires conducted on the SNU X-pinch at a current rise rate of ∼0.2 kA/ns. Analysis of the spectra reveals that the first burst comprises x-rays emitted by hot spots and electron beams, with characteristics similar to those observed in other X-pinches. The second and third bursts are both generated by long-lived electron beams formed after the neck structure has been completely depleted. In the second burst, the formation of the electron beam is accompanied by an increase in the electron density of the background plasma. Therefore, the long-lived electron beams generate the additional strong x-ray bursts while maintaining a plasma channel in the central region of the X-pinch. Moreover, they emit many hard x-rays (HXRs), enabling the SNU X-pinch to be used as an HXR source. This study confirms that the generation of long-lived electron beams is crucial to the dynamics of X-pinches and the generation of strong HXRs.
1 May 2021 in Review of Scientific Instruments
This paper describes an X-pinch device recently developed at Seoul National University (SNU). The SNU X-pinch device is designed and fabricated to accommodate various diagnostics as well as conduct versatile experiments. It is easy to change the capacitance of the pulse generator because the capacitor bank has a modular design without insulation oil or gas. This allows us to perform a variety of experiments with a wide capacitance range from 80 to 800 nF. The operating voltage of the SNU X-pinch device is controlled from 20 to 100 kV by adjusting the gas pressure inside a triggered spark-gap switch. Triggering of the spark-gap switch is synchronized with the operation of a pulsed laser to diagnose the X-pinch plasma at the proper time. A large vacuum chamber precisely machined from an aluminum mono-block is attached to the top of the pulse generator. It is designed to accommodate not only various X-pinch loads but also various diagnostic apparatus such as optical components. Initial experiments with the SNU X-pinch device have successfully generated x rays with wires of various materials and sizes. The device will be used not only to explore the dynamics of X-pinch plasmas but also as a test stand for diagnostics of high-energy-density plasmas.
1 May 2021 in Review of Scientific Instruments
We develop a filtered absolute extreme ultraviolet (AXUV) diode array to measure the time evolution of the soft x-ray spectrum in the energy range of 1–10 keV. AXUV–HS5, the detector, has a fast rise time of 0.7 ns, a wide energy detection range, and high accessibility. We use Geant4 simulations to design an appropriate filter set for flat-and-sharp virtual channels (VCs), where a filter with no spectral edge removes large tails of the response curves. A Levenberg–Marquardt (LM) method, sensitive to the expected spectral function, is improved to reliably generate a continuous radiation spectrum, by utilizing spectral information from the least-squares (LS) method that reconstructs a discrete spectrum with low spectral resolution directly from the VCs. We test the filtered AXUV diode array on an X-pinch device with a peak current of 140 kA at Seoul National University; the array with ten channels is installed in a vacuum chamber. For a two-wire 40 μm stainless steel X-pinch, x-ray power, radiation temperature, and the reconstructed x-ray spectrum are obtained from the filtered AXUV diode array by the combined LS–LM method.
1 April 2021 in Review of Scientific Instruments
Having a sub-ns response time and not requiring physical contacts to the measurement points, a voltage measurement system based on the Pockels electro-optic effect, referred to as a PE (Pockels effect)-based voltmeter, is widely used for pulsed high voltage devices such as accelerators and X-pinch systems. To correct for the misalignment of a Pockels cell and the transmittance ratio of a beam splitter, a polar-coordinate-based data analysis scheme has been proposed. This scheme also overcomes a limitation on the measurable range of a PE-based voltmeter without ambiguity and can measure the half-wave voltage of a Pockels cell. We present an improved polar-coordinate-based data analysis scheme using an ellipse fitting method, which can correct for misalignments of all the optics components of a PE-based voltmeter while keeping the advantages of the previous scheme. We show the results of the improved data analysis scheme for measuring a slowly modulated voltage up to approximately 5 kV in about 30 s and a pulsed high voltage up to 7 kV with a rise time of less than 20 ns.
1 July 2024 in Review of Scientific Instruments
Optics-based measurement systems have been developed to measure the voltage and the current on a load of the Seoul National University X-pinch device [Ryu et al., Rev. Sci. Instrum. 92, 053533 (2021)]. A lithium niobate crystal that changes the polarization state of the propagating laser beam due to the Pockels effect induced by the electric field across the crystal, thus capable of measuring the voltage, is located next to the load. For the current measurement, an optic fiber is wound around the load to detect the change in the polarization state of the propagating laser beam due to the Faraday rotation induced by the magnetic field. As both voltage and current measurement systems utilize optical effects, the sensors, i.e., the lithium niobate crystal and the optic fiber, do not require any electrical grounds, in contrast to circuit-based probes, such as voltage dividers or Rogowski grooves. This facilitates an easy access to shield other required electronic devices, such as lasers and photodetectors, from the electromagnetic interference generated by the X-pinch power system. In addition, the sensors can be placed in close proximity to the load with fewer concerns on the electrical insulation. Temporal evolutions of the simultaneously measured voltage and current on the load of the X-pinch are successfully obtained and discussed.