Jung-Hwa Kim

Jung-Hwa Kim

Auto-generated profile, based on publicly available information

Jung-Hwa Kim

Korea Institute of Fusion Energy, 169-148 Gwahak-ro, Yuseong-gu, Daejeon, Republic of Korea

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JKJung-Hwa Kim
Jung-Hwa Kim
YKYoung-Gi Kim
Young-Gi Kim
DKDoyeon Kim
Doyeon Kim
JLJong-Ha Lee
Jong-Ha Lee
YHY. S. Hwang
Y. S. Hwang
A Thomson scattering (TS) system has been utilized to measure the electron temperature and density of the core region of Versatile Experiment Spherical Torus (VEST). Recently, the laser injection system is successfully upgraded adopting the burst laser with the repetition rate of 1 kHz and the energy of 2 J. Furthermore, improved collection optics with additional polychromators and a 32-channel fast digitizer are prepared to observe the fast time evolution of radial profiles. This improvement is essential to study fast phenomena such as internal reconnection event (IRE). We increase the TS signal and reduce the stray light by introducing new filters having better optical properties such as high optical density at 1064 nm, transmission, and reflectance. Moreover, the optimum reverse bias voltages are newly set to make the system operational independent of the background radiation. As a result, 1 kHz radial profiles of the core electron temperature and density are measured for the first time, showing characteristics of IREs in VEST.

1 October 2021 in Fusion Engineering and Design
Verified
Journal Article
Closed access
KLKihyun Lee
Kihyun Lee
SLSoonghyeong Lee
Soonghyeong Lee
JJJae Young Jang
Jae Young Jang
JKJung-Hwa Kim
Jung-Hwa Kim
SKSeongcheol Kim
Seongcheol Kim
YHY.S. Hwang
Y.S. Hwang

16 April 2024 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
JKJung-Hwa Kim
Jung-Hwa Kim
JLJongmin Lee
Jongmin Lee
YKYoung-Gi Kim
Young-Gi Kim
SKSeongCheol Kim
SeongCheol Kim
JWJongin Wang
Jongin Wang
YHY. S. Hwang
Y. S. Hwang
The Thomson scattering (TS) system is a main plasma diagnostic tool used on the Versatile Experiment Spherical Torus (VEST). An upgrade to the 1 kHz TS system has been completed, allowing for the measurement of rapidly changing radial profiles of the electron temperature and density in the core plasma. Additionally, the upgrade of the bandpass filters of the polychromators enables rotational Raman scattering (RRS) calibration, which improves the accuracy of density calibration compared to Rayleigh scattering (RS) methods. However, systematic errors in the relative sensitivity calibration can lead to significant changes in the results. By analyzing discrepancies in the Raman calibration signals for three filters, the causes of these errors are identified and corrected with a fast infrared (IR) LED. As a result, the calibration factors for RRS and their uncertainties are obtained for measuring absolute electron density, and the relative responsivity of each polychromator is corrected to increase the reliability of the TS system.

1 September 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JYJ. W. Yoo
J. W. Yoo
CSChoongki Sung
Choongki Sung
TET. H. Eom
T. H. Eom
WLW. S. Lee
W. S. Lee
JKJ. H. Kim
J. H. Kim
YHYong-Seok Hwang
Yong-Seok Hwang
A diagnostic system for measuring the effective charge in the versatile experiment spherical torus (VEST) has been developed. The system utilizes a toroidal array to observe the plasma radius on the low magnetic field side, providing a spatially resolved Zeff. The target wavelength of visible bremsstrahlung (VB) was carefully selected to avoid contamination by line emissions. The detector signal was calibrated using a halogen light source and an integrating sphere to obtain an absolute value of the radiative power from each chord. The local emissivity profile was reconstructed from the line-integrated VB emission using the Abel inversion method. Reconstruction tests were performed on various shapes of phantom profiles to effectively reconstruct the local emissivity from the measurements. We found that the initial measurements of the multi-channel VB system were consistent with the results of other independent measurements, supporting the validity of the new measurements. Finally, we obtained the initial result of Zeff in the VEST.

1 July 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SCSeongmin Choi
Seongmin Choi
SHSeunggi Ham
Seunggi Ham
JRJonghyeon Ryu
Jonghyeon Ryu
SPSungbin Park
Sungbin Park
JKJung-Hwa Kim
Jung-Hwa Kim
YGY.-C. Ghim
Y.-C. Ghim
Optics-based measurement systems have been developed to measure the voltage and the current on a load of the Seoul National University X-pinch device [Ryu et al., Rev. Sci. Instrum. 92, 053533 (2021)]. A lithium niobate crystal that changes the polarization state of the propagating laser beam due to the Pockels effect induced by the electric field across the crystal, thus capable of measuring the voltage, is located next to the load. For the current measurement, an optic fiber is wound around the load to detect the change in the polarization state of the propagating laser beam due to the Faraday rotation induced by the magnetic field. As both voltage and current measurement systems utilize optical effects, the sensors, i.e., the lithium niobate crystal and the optic fiber, do not require any electrical grounds, in contrast to circuit-based probes, such as voltage dividers or Rogowski grooves. This facilitates an easy access to shield other required electronic devices, such as lasers and photodetectors, from the electromagnetic interference generated by the X-pinch power system. In addition, the sensors can be placed in close proximity to the load with fewer concerns on the electrical insulation. Temporal evolutions of the simultaneously measured voltage and current on the load of the X-pinch are successfully obtained and discussed.

28 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
JLJongmin Lee
Jongmin Lee
YKYoung-Gi Kim
Young-Gi Kim
JKJung-Hwa Kim
Jung-Hwa Kim
JLJong Ha Lee
Jong Ha Lee
YHYong-Seok Hwang
Yong-Seok Hwang
An edge Thomson scattering (TS) diagnostic system has been developed and commissioned on the Versatile Experiment Spherical Torus (VEST) to extend kinetic profile measurements into the edge region and scrape-off layer (SOL). The new system shares the existing laser injection system with the core TS (2 J, 10 ns, 10 bursts at 1 kHz) and is designed to cover the low-field-side radial range of R = 0.475 – 0.800 m, complementing the core TS coverage of R = 0.255 – 0.475 m. Absolute calibration of the new edge TS system was performed via rotational Raman scattering measurements. To validate consistency between the two collection optics systems, 150 datasets acquired from 15 discharges at the same radial position (R = 0.475 m; core 1 and edge 1) were analyzed using a chi-square test of homogeneity. The results indicate agreement within uncertainties for both electron density and temperature. As an initial commissioning demonstration, pilot operation measurements were performed at four radial positions (R = 0.255, 0.370, 0.475 and 0.700 m) and produced edge electron density and electron temperature profiles over a 10 ms period. The installation of the edge TS system enables a wider spatial coverage (R = 0.255 – 0.800 m) for more detailed kinetic profiling, with planned expansion through additional polychromators to increase the number of measurement points and support future studies such as edge transport and instabilities.