Zakaria Tahiri

Zakaria Tahiri

Auto-generated profile, based on publicly available information

Zakaria Tahiri

Biophysics Laboratory, Life and Health Sciences Research Laboratory, Faculty of Medicine and Pharmacy of Tangier, Abdelmalek Essaâdi University, Tetouan, Morocco

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Radioprotection
Verified
Journal Article
Closed access
PDF file
ZTZ. Tahiri
Z. Tahiri
MTMohammed TALBI
Mohammed TALBI
MMM'hamed EL MANSOURI
M'hamed EL MANSOURI
The large use of Computed Tomography Scan (CT scan) is a principal cause of increasing medical ionizing radiation exposure. Children are considered a population at risk for the occurrence of radiation-induced pathologies, and the implementation of radiation protection measures relies on the knowledge and skills of healthcare professionals. This analytical cross-sectional study aimed to assess the knowledge of Moroccan physicians prescribing pediatric CT scan examinations on the radiation protection of patients, radiation doses, and potential health risks of radiation exposure from CT scan. A questionnaire was distributed to all clinicians on the medical staff who prescribe pediatric CT examinations in five Moroccan pediatric hospitals. The questions have a focusing on prescribers’ practices and their knowledge of patient radiation protection, radiation doses, the potential health risks of radiation exposure from CT scan, and training on radiation protection. One hundred and ninety-two questionnaires were submitted to prescribers and among them, 88% responded. The data were analyzed using the Statistical Package of Microsoft Office Excel. Knowledge gaps regarding CT scan radiation doses and associated health risks among Moroccan physicians are evident from this study results, initial and continuing training of health care staff and the implementation of referral guidelines for medical imaging could lead to improve practitioners’ knowledge of patient radiation protection.

28 March 2021 in Biomedical and Pharmacology Journal
Verified
Journal Article
Open access
ZTZakaria Tahiri
Zakaria Tahiri
MMMounir Mkimel
Mounir Mkimel
LJLaila Jroundi
Laila Jroundi
FLFatima Zahra Laamrani
Fatima Zahra Laamrani
Digital Mammography is used as a screening tool to discover breast cancer at an early stage, the benefits and harms of this techniques is under scrutiny hence and Moroccan regulations governing radiation protection of patients have been strengthened, the need to investigate the dose received during screening mammography and the risk associated. This study is consisted of examining 126 mammography projections, for 63 women. All examinations were performed with a full digital mammography machine, technical and exposure parameters were recorded, statistical analysis was carried out using Microsoft Excel in order to calculate local DRLs and compare them with international standards. Cancer risk has been estimated using BEIR VII report methods. The mean glandular dose MGD was 1,09±0, 45 mGy and 1,26±0,74 mGy for craniocaudal (CC) and mediolateral oblique (MLO) respectively, DRLs were 1,34 for CC view and 1,36 for MLO view. Of the 100,000 women exposed, Lifetime Attributable Risk of cancer incidence has been found to be 0,76 for CC examination, 0.88 for MLO, and 1,64 for the full mammography protocol. Established local DRLs in this study are lower compared to that of United Kingdom and France and higher compared to that of Nigeria and Australia. A potential risk of radiation-induced carcinogenesis exists, and there is a need for optimization of screening mammography practices.

1 April 2024 in Radioprotection
Verified
Journal Article
Open access
PDF file
ZTZ. Tahiri
Z. Tahiri
MTM. Talbi
M. Talbi
MMM. El Mansouri
M. El Mansouri
HSH. Sekkat
H. Sekkat
MMM. Mkimel
M. Mkimel
SHS. Hiroual
S. Hiroual
This observational cross-sectional study aims to assess the exposure levels during mammography examinations in Morocco and provide an international comparative analysis. Patient data from 1100 mammographic examinations conducted in five units, comprising both digital radiography (DR) and computed radiography (CR) systems from various brands and models in the Rabat-Salé-Zemmour-Zaër region, were collected. The mean glandular dose (MGD) and technical parameters, including exposure factors and breast thickness, were analyzed. The collected data were compared with findings from international studies to provide valuable context. The overall median MGD was 1.34 ± 0.36 mGy for craniocaudal (CC) and 1.48 ± 0.38 mGy for mediolateral oblique (MLO) incidences. It’s essential to note that these values were calculated based on the median compressed breast thickness. The MGD varied among different units and anode/filter combinations. The Rh/Rh anode/filter combination was most commonly used, resulting in the lowest radiation dose. The study findings also highlighted the relationship between MGD and breast thickness, with higher doses observed for thicker breasts. This study provides valuable insights into radiation exposure during mammography breast cancer screening in Morocco. The results underscore the importance of future dose optimization strategies to ensure patient safety without compromising diagnostic image quality. Implementing optimized technical parameters, conducting regular quality assurance programs, and promoting education and awareness are essential in achieving dose reduction and minimizing radiation risks. Collaboration among healthcare professionals, regulatory bodies, and international organizations is crucial for sharing best practices and advancing radiation dose optimization in mammography.

11 March 2022 in Radioprotection
Verified
Journal Article
Closed access
PDF file
MTMohammed TALBI
Mohammed TALBI
ZTZ. Tahiri
Z. Tahiri
KEK. Eddaoui
K. Eddaoui
MMM'hamed EL MANSOURI
M'hamed EL MANSOURI
ONO. Nhila
O. Nhila
MKM. Khalis
M. Khalis
In Morocco, the radiation protection of patients undergoing medical imaging examinations using ionizing radiation sources is now governed by specific provisions of Chapter VII of Law no142-12 (Loi no142-12 – AMSSNuR, 2015). The principle of justification of procedures and the principle of optimization of doses delivered constitute the basis of the legislation governing medical exposure. DRLs are considered as an important optimization tool encouraging healthcare professionals to optimize their practice and assure a better patient safety. In this survey, Local Diagnostic Reference Levels (LDRLs) were established for the eight most frequent examinations in Morocco. Data from 1747 patients were collected from seven regional hospitals. The proposed LDRLs were defined as the 75th percentile of the mean entrance surface dose distribution (ESD) in mGy using the indirect dosimetry method according to the IAEA Report Series No. 457. The LDRLs values reported in this study were for the eight examinations: skull (PA) 2.8 mGy, chest (PA) 0.51 mGy, abdomen (AP) 7.6 mGy, pelvis (AP) 6.45 mGy, lumbar (AP) 7.8 mGy, lumbar (Lat) 10.7 mGy, cervical (AP) 2.2 mGy, and cervical (Lat) 2.4 mGy. The DRLs reported in Morocco were compared with those of international authorities and other countries: IRSN (France), NRPB (UK), Japan, Sudan, and Iran. The present work assesses the local DRLs in Morocco and constitutes a starting point that will provide professionals with a tool to help them optimize the doses delivered to patients. Furthermore, the definition of national DRLs by radiography is an essential step in the process of optimizing medical exposures.

6 November 2024 in Physica Scripta
Verified
Journal Article
Closed access
HSHamza Sekkat
Hamza Sekkat
AKAbdellah Khallouqi
Abdellah Khallouqi
YMYoussef Madkouri
Youssef Madkouri
WAWiam El Atifi
Wiam El Atifi
IRImane Rhouch
Imane Rhouch
AHAbdellah Halimi
Abdellah Halimi
Accurate dosimetry in computed tomography (CT) is essential for patient safety and effective radiation management. This study presents the development of an automated algorithm designed to enhance patient dosimetry by facilitating size-specific dose estimates (SSDE) and organ dose estimations. Utilizing a Python-based script, the proposed method integrates advanced image preprocessing, contour detection, and mathematical calculations to quantify key metrics from CT images. This automated approach addresses the limitations of manual measurement techniques. A retrospective analysis was conducted on CT axial images from examinations acquired with an 80-detector scanner. The algorithm processes DICOM images, converts pixel values to Hounsfield Units, applies Gaussian smoothing, windowing, and thresholding, followed by morphological operations to refine segmentation. It measures the water equivalent diameter (Dw) and estimates both region SSDE and organ doses, incorporating tissue attenuation. Validation was performed using an adult anthropomorphic ATOM phantom, with organ doses measured by optically stimulated luminescence dosimeters. The results demonstrated the algorithm’s potential in estimating SSDE and organ doses. Validation of the automated method revealed strong correlations for Dw and SSDE between the proposed method and manual measurements of five expert reviewers ranging from 0.86 to 0.99 for determination coefficient. Comparative analysis of organ doses showed close agreement between results from experimental setup against the proposed algorithm. The automated algorithm estimated brain dose with a mean of 21.8 mGy, while measurements from the ATOM phantom and CT Expo indicated 19.74 mGy and 23.05 mGy, respectively. For lung doses, the automated algorithm estimated 12.5 mGy compared to 11.0 mGy from the ATOM phantom and 13.1 mGy from CT Expo. Liver doses were measured at 12.7 mGy by the automated method, versus 12.1 mGy from the ATOM phantom and 11.1 mGy from CT Expo. This study shows the potential of automated image analysis techniques in enhancing dosimetry accuracy in CT examinations.

31 August 2023 in Journal of Failure Analysis and Prevention
Verified
Journal Article
Closed access
PDF file
MMM'hamed EL MANSOURI
M'hamed EL MANSOURI
MTMohammed TALBI
Mohammed TALBI
ZTZakaria Tahiri
Zakaria Tahiri
ONOussama Nhila
Oussama Nhila
MKMorad El Kafhali
Morad El Kafhali
HSHamza Sekkat
Hamza Sekkat