Hamza Sekkat

Hamza Sekkat

Auto-generated profile, based on publicly available information

Hamza Sekkat

Sciences and Engineering of Biomedicals, Biophysics and Health Laboratory, Higher Institute of Health Sciences, Hassan First University, Settat, 26000, Morocco; Higher Institute of Nursing Professions and Health Techniques, Rabat, Morocco

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2025 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
HSHamza Sekkat
Hamza Sekkat
AKAbdellah Khallouqi
Abdellah Khallouqi
OROmar El Rhazouani
Omar El Rhazouani
YMYoussef Madkouri
Youssef Madkouri
AHAbdellah Halimi
Abdellah Halimi

28 August 2024 in Journal of Failure Analysis and Prevention
Verified
Journal Article
Closed access
PDF file
HSHamza Sekkat
Hamza Sekkat
YMYoussef Madkouri
Youssef Madkouri
AKAbdellah Khallouqi
Abdellah Khallouqi
OROmar El Rhazouani
Omar El Rhazouani

1 July 2024 in Radioprotection
Verified
Journal Article
Open access
PDF file
HSH. Sekkat
H. Sekkat
KEK. Elmansouri
K. Elmansouri
AKA. Khallouqi
A. Khallouqi
AHA. Halimi
A. Halimi
ORO. El Rhazouani
O. El Rhazouani
MMM. El Mansouri
M. El Mansouri
Accurate dose estimation in computed tomography (CT) scans is crucial and relies on precise normalization of output dose, typically measured by the volume CT dose index (CTDIvol). Key metrics, including effective diameter (Deff) and water-equivalent diameter (Dw), play pivotal roles in characterizing patient size. However, a notable gap exists in delineating the specific relationships between age and head patient size (Deff and Dw) for pediatric patients in Morocco. The primary objective of this study was to establish these critical associations between patient age and head patient size (Deff and Dw), providing a foundation for calculating size-specific dose estimates (SSDE) in pediatric head CT examinations. A retrospective analysis of data from 134 pediatric patients, aged 0–13 yr, comprising 71 males and 63 females who underwent head CT scans, was conducted. Utilizing the Radiant DICOM Viewer, patient sizes were measured in terms of both lateral and anterior-posterior dimensions for Deff and Dw calculations based on CT images in DICOM format. Our analysis revealed robust correlations between patient size (Deff and Dw) and the patient’s age, with R2 values ranging from 0.65 to 0.86. Notably, larger Dw values were consistently observed compared to Deff. For male patients, Deff measurements ranged from 9.02 to 18.77 cm, with Dw values spanning 9.83 to 20.16 cm. Female patients exhibited Deff values ranging from 8.77 to 17.41 cm and Dw values ranging from 8.92 to 18.37 cm. These findings shed light on the crucial relationship between age and patient size, facilitating more precise dose calculations.

18 January 2024 in Journal of Failure Analysis and Prevention
Verified
Journal Article
Closed access
PDF file
MMM’hAmed El Mansouri
M’hAmed El Mansouri
HSHamza Sekkat
Hamza Sekkat
MTMohammed Talbi
Mohammed Talbi
ZTZakaria Tahiri
Zakaria Tahiri
ONOussama Nhila
Oussama Nhila

6 November 2024 in Physica Scripta
Verified
Journal Article
Closed access
HSHamza Sekkat
Hamza Sekkat
AKAbdellah Khallouqi
Abdellah Khallouqi
YMYoussef Madkouri
Youssef Madkouri
WAWiam El Atifi
Wiam El Atifi
IRImane Rhouch
Imane Rhouch
AHAbdellah Halimi
Abdellah Halimi
Accurate dosimetry in computed tomography (CT) is essential for patient safety and effective radiation management. This study presents the development of an automated algorithm designed to enhance patient dosimetry by facilitating size-specific dose estimates (SSDE) and organ dose estimations. Utilizing a Python-based script, the proposed method integrates advanced image preprocessing, contour detection, and mathematical calculations to quantify key metrics from CT images. This automated approach addresses the limitations of manual measurement techniques. A retrospective analysis was conducted on CT axial images from examinations acquired with an 80-detector scanner. The algorithm processes DICOM images, converts pixel values to Hounsfield Units, applies Gaussian smoothing, windowing, and thresholding, followed by morphological operations to refine segmentation. It measures the water equivalent diameter (Dw) and estimates both region SSDE and organ doses, incorporating tissue attenuation. Validation was performed using an adult anthropomorphic ATOM phantom, with organ doses measured by optically stimulated luminescence dosimeters. The results demonstrated the algorithm’s potential in estimating SSDE and organ doses. Validation of the automated method revealed strong correlations for Dw and SSDE between the proposed method and manual measurements of five expert reviewers ranging from 0.86 to 0.99 for determination coefficient. Comparative analysis of organ doses showed close agreement between results from experimental setup against the proposed algorithm. The automated algorithm estimated brain dose with a mean of 21.8 mGy, while measurements from the ATOM phantom and CT Expo indicated 19.74 mGy and 23.05 mGy, respectively. For lung doses, the automated algorithm estimated 12.5 mGy compared to 11.0 mGy from the ATOM phantom and 13.1 mGy from CT Expo. Liver doses were measured at 12.7 mGy by the automated method, versus 12.1 mGy from the ATOM phantom and 11.1 mGy from CT Expo. This study shows the potential of automated image analysis techniques in enhancing dosimetry accuracy in CT examinations.

31 August 2023 in Journal of Failure Analysis and Prevention
Verified
Journal Article
Closed access
PDF file
MMM'hamed EL MANSOURI
M'hamed EL MANSOURI
MTMohammed TALBI
Mohammed TALBI
ZTZakaria Tahiri
Zakaria Tahiri
ONOussama Nhila
Oussama Nhila
MKMorad El Kafhali
Morad El Kafhali
HSHamza Sekkat
Hamza Sekkat