Ihor Maladyka

Ihor Maladyka

Auto-generated profile, based on publicly available information

Ihor Maladyka

Cherkasy State Technological University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2022 in Advances in Science and Technology
Verified
Conference Paper
Closed access
PDF file
IMIhor Maladyka
Ihor Maladyka
SSSerhiy Stas
Serhiy Stas
PMPustovit Mykhailo
Pustovit Mykhailo
ODOleksandr Dzhulay
Oleksandr Dzhulay
The appearance in widespread use of unmanned aerial vehicles, both multi-rotor and wing-carrying aircraft, revealed the possibility of their use in the activities of the State Emergency Service of Ukraine. They can be used for emergency reconnaissance, aerial surveying, search operations, aviation chemical work related to the circulation of hazardous substances, monitoring of territories and objects, transmission of radio signals, delivery to the site of emergencies various types of payload, conducting alerting, lighting emergency situations and direct firefighting. Therefore, the issue of using unmanned aerial vehicles in the activities of the State Emergency Service of Ukraine is relevant. In essence, the use of an unmanned aerial vehicle is reduced to two main types of work - observation or work around a point object or movement over long distances to ensure work on the earth's surface. It is clear that the technical characteristics of the unmanned aerial vehicle determines its suitability for use in the relevant types of work. One of these characteristics is the range of radio communication, the busiest channel of which is real-time video communication, which is essential for most assigned tasks. The article attempts to estimate the range of video data transmission by radio for the most common models of multi-rotor unmanned aerial vehicles of mass production and video data transmission systems that can be used optionally. To this end, we analyze the characteristics of video transmission systems, factors that affect the quality of video communication and others. Existing mass-produced models are best suited to work around a point object. Their use for long-distance flights will be limited by the range of video data transmission. By overcoming this situation, the authors see the use of unified unmanned aerial vehicles equipping them with optional video transmission systems.

28 February 2026 in Technology audit and production reserves
Verified
Journal Article
Open access
PDF file
ZMZakhar Matsuk
Zakhar Matsuk
ABAnatolii Bielikov
Anatolii Bielikov
IMIhor Maladyka
Ihor Maladyka
OTOleksandr Tyshchenko
Oleksandr Tyshchenko
VKVadim Kharchenko
Vadim Kharchenko
The object of research is the process of assessing the level of safety of complex technical systems of critical infrastructure under conditions of uncertainty. The problem of the limitations and asymmetry of risk assessment methods was investigated. Risk assessment processes were studied based on IAEA data, using a combination of theoretical and computational modeling methods. The theoretical basis was based on factor risk analysis. Dynamic and temporal dependencies were taken into account using a synthesized modular scalable dynamic Bayesian network (MSDBN), which integrated local components and their interaction into hierarchical models. Probabilistic assessments were performed using Monte Carlo simulation, as well as structural and hybrid learning algorithms for Bayesian networks. The limitations, asymmetry, and dependence on expert opinion of traditional risk assessment methods were shown. It was shown that the synthesis of Bayesian networks and the Monte Carlo method as basic approaches meets the criteria for symmetry in risk event modeling. It was established that the maximum adequacy of risk event prediction is achieved when using a modular Bayesian architecture with a multi-criteria approach through assessing the compliance of production system elements with regulatory requirements, historical analogies and/or modeling results. MSDBN improves the quality and validity of management decisions, is integrated into automated control systems, serves as a tool for digital twins, can be used in the educational process, is symmetric and suitable for assessing the effectiveness of security measures. The proposed approach is useful for state, defense and industrial systems, including under conditions of uncertainty.

30 May 2026 in Technogenic and Ecological Safety
Verified
Journal Article
Open access
LYLyudmyla Yashchuk
Lyudmyla Yashchuk
IMIhor Maladyka
Ihor Maladyka
Особливістю війни впродовж 2024–2026 років є скоординована військова кампанія ворога на руйнування електроенергетичної сфери України. Українські електропідстанції, особливо радянського періоду будівництва, обладнані трансформаторами, що заповнені трансформаторними оливами з високим вмістом ПХБ. Ураження таких підстанцій спричиняє виливи трансформаторних олив у довкілля. Для ліквідації осередків виливів нафтопродуктів використовують сорбенти штучного та органічного походження. В роботі проаналізовано фізико-хімічні властивості 5 сорбентів: нафтоємність, гідрофобність, швидкість дії. При оцінці економічної ефективності сорбентів трансформаторної оливи враховувалась їх насипна густина (об’ємна вага), вартість у вітчизняній торгівельній мережі, заявлена виробниками сорбційну ємність. Для оцінки ефективності вибраних сорбентів використовувався гравіметричний та розрахунковий методи. В роботі також проведено порівняльний аналіз сорбційної ємності досліджуваних зразків сорбентів трансформаторної оливи. Експерименти проведено в лабораторних умовах взимку (температура повітря +15°C ), та навесні (+25°C ) 2024–2025 років. В якості нафтопродукту використано трансформаторну оливу марки Т-1500 (ДСТУ 4452:2005). Необхідною умовою під час вибору зразків сорбентів було їх виробництво вітчизняними виробниками в Україні. За результатами проведених досліджень та розрахунків найбільш перспективним для ліквідації розливів трансформаторних олив є Термографеніт Е. Недоліками біосорбентів Еконадіну та Еколану М є: висока вартість, обмеженість сорбційних властивостей при низьких температурах, повільність дії. Низька вартість деревної тирси робить її привабливим сорбентом для власників енергоустановок, але складнощі із збором відпрацьованої тирси та проблема подальшої її утилізації обмежують вибір. Практична цінність дослідження полягає у оптимізації вибору вітчизняних сорбентів для ліквідації наслідків розливів трансформаторних олив із врахуванням їх переваг та недоліків.

1 January 2022 in Emergency Situations: Prevention and Liquidation
Verified
Journal Article
Open access
PDF file
CUCherkasy Institute of Fire Safety named after Chornobyl Heroes of National University of Civil Protection of Ukraine
Cherkasy Institute of Fire Safety named after Chornobyl Heroes of National University of Civil Protection of Ukraine
ABAndrii Berezovskyi
Andrii Berezovskyi
IMIhor Maladyka
Ihor Maladyka
OKOleh Kulitsa
Oleh Kulitsa
Computational experiments using computer simulation were carried out in the work. An identical sample of a steel plate coated with a fire retardant material that swells when exposed to the heat from a fire was reproduced. Developed and built thermal mathematical models of the specified sample with the conditions of influence of the standard fire temperature regime lasting 30 min., 45 min., 60 min. The results of the practical experiment and the indicators obtained as a result of the calculations are analyzed. According to the results of computer experiments, it was established that under the action of the standard temperature mode of fire lasting 30 min., 45 min., 60 min. the error compared with experimental tests was 3.5% on average. Analyzing the obtained results, the largest error in the obtained indicators is observed during the fire during 30 minutes. and is 4.1%. The operation of these models is based on the non-stationary differential equation of thermal conductivity with numerical approximation using the finite element method. According to the results of the numerical experiments, the temperature distribution on the surface of the steel plate from the side that is not heated under the influence of the standard temperature regime of the fire at different moments of time was determined. Based on the results of numerical experiments, a method was developed to determine the effectiveness of the fire-resistant material that swells under the influence of fire for steel structures, which significantly simplifies such calculations and does not affect the accuracy of the obtained results. У роботі проведені обчислювальні експерименти за допомогою комп’ютерного моделювання. Був відтворений ідентичний зразок сталевої пластини із нанесенням вогнезахисного матеріалу, що спучується при впливі температури від пожежі. Розроблені та побудовані теплові математичні моделі вказаного зразка з умовами впливу стандартного температурного режиму пожежі тривалістю 30 хв., 45 хв., 60 хв. Проаналізовані результати практичного експерименту та показники, що отримані у результаті розрахунків. За результатами проведених обчислювальних експериментів встановлено, що при дії стандартного температурного режиму пожежі тривалістю 30 хв., 45 хв., 60 хв. похибка із порівнянням із експериментальними випробуваннями склала у середньому 3,5 %. Аналізуючи отримані результати, спостерігається найбільша похибка в отриманих показниках при дії пожежі протягом 30 хв та становить 4,1 %. Робота даних моделей ґрунтується на основі нестаціонарного диференціального рівняння теплопровідності з чисельною апроксимацією за допомогою методу кінцевих елементів. За результатами проведених чисельних експериментів було визначено Розподіл температури по поверхні сталевої пластини з боку, що не обігрівається при впливі стандартного температурного режиму пожежі у різні моменту часу. За результатами проведених чисельних експериментів була розроблена методика щодо визначення ефективності вогнезахисного матеріалу, що спучується при впливі пожежі для сталевих конструкцій, що істотно спрощує проведення таких розрахунків, і не впливає на точність отриманих результатів.

1 January 2023 in Emergency Situations: Prevention and Liquidation
Verified
Journal Article
Open access
PDF file
CUCherkassy Institute of Fire Safety Named after Chernobyl Heroes ofNational University of Civil Defense of Ukraine
Cherkassy Institute of Fire Safety Named after Chernobyl Heroes ofNational University of Civil Defense of Ukraine
MPMaksym Pustovyi
Maksym Pustovyi
IMIgor Maladyka
Igor Maladyka
SNSerhii Novak
Serhii Novak
IPInstitute of public administration and research in civil protection
Institute of public administration and research in civil protection
The purpose of the conducted research was to identify unsolved issues regarding the assessment of the required fire protection thickness for steel structures under conditions of fire exposure at different fire temperature-time curve and to determine directions for further research. In order to achieve this goal, the task of determining and analyzing the current requirements for the fire resistance of steel structures, the applicable methods for assessing the fire resistance of these structures and the required thickness of their fire protection, the available data on the significance of this thickness, obtained for different fire temperature-time curve, was solved. According to the results of the research, it was found that in accordance with European and national standards and state building codes, fire resistance requirements and fire resistance classification of load-bearing structures without enclosing functions, such as beams and columns, are established only for conditions of fire exposure under a standard temperature/time curve. At the same time, Eurocodes 1, 3 and national standards provide for assessing the fire resistance of such steel structures also according to the temperature-time curves of hydrocarbon and external fires. Methods of determining the required minimum thickness of fire protection for steel structures are implemented in European and national standards also only for conditions of fire exposure under a standard temperature/time curve. The procedure for determining this thickness for the conditions of fire exposure according to the temperature-time curves of hydrocarbon and external fires is uncertain. Also uncertain is the issue of dependencies regarding the required minimum thickness of fire protection for steel structures that are subject to fire exposure at other than the standard temperature-time curve, nominal fire temperature-time curves, as well as data on the relationship between the values of this thickness obtained under different nominal temperature-time curves. Such uncertainty gives rise to potentially interesting areas of further research, which are focused on identifying the influence of nominal fire temperature-time curves on the required minimum thickness of fire protection for such steel structures as beams and columns, for wide ranges of changes in the thermophysical properties of applicable fire protection materials, the critical temperature of steel, the cross-section coefficient and the time interval of preservation of fire resistance. Проведене дослідження ставило за мету виявлення невирішених питань щодо оцінювання необхідної товщини вогнезахисту для сталевих конструкцій в умовах вогневого впливу за різними температурними режимами пожежі та визначення напрямів подальших досліджень. Для досягнення цієї мети було розв’язано завдання щодо визначення і аналізу чинних вимог до вогнестійкості сталевих конструкцій, застосовних методів оцінювання вогнестійкості цих конструкцій і необхідної товщини їхнього вогнезахисту, наявних даних стосовно значень цієї товщини, отриманих для різних температурних режимів пожежі. За результатами проведеного дослідження виявлено, що відповідно до європейських і національних стандартів і державних будівельних норм вимоги до вогнестійкості і класифікацію за вогнестійкістю несучих конструкцій без огороджувальних функцій, таких як балок і колон, встановлено тільки для умов вогневого впливу за стандартного температурного режиму. Водночас в Єврокодах 1, 3 і національних стандартах передбачено проведення оцінювання вогнестійкості таких сталевих конструкцій також за температурними режимами вуглеводневої і зовнішньої пожеж. Методи визначення необхідної мінімальної товщини вогнезахисту для сталевих конструкцій реаламентовано в європейських і національних стандартах також тільки для умов вогневого впливу за стандартного температурного режиму. Процедура оцінювання цієї товщини для умов вогневого впливу за температурними режимами вуглеводневої і зовнішньої пожеж є невизначеною. Невизначеним також є питання стосовно залежностей щодо необхідної мінімальної товщини вогнезахисту для сталевих конструкцій, які стосуються вогневого впливу за іншими ніж стандартний номінальними температурними режимами пожежі, а також даних щодо співвідношення між значеннями цієї товщини, отриманими за різними номінальними режимами. Така невизначеність породжує...

25 May 2026 in Bulletin of Lviv State University of Life Safety
Verified
Journal Article
Closed access
OTO. M. Tyshchenko
O. M. Tyshchenko
IMI. H. Maladyka
I. H. Maladyka
ITI. O. Tyshchenko
I. O. Tyshchenko
DKD. O. Kotliar
D. O. Kotliar
MSM. P. Sorochych
M. P. Sorochych