Johannes Mayer

Johannes Mayer

Auto-generated profile, based on publicly available information

Johannes Mayer

Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Computer Physics Communications
Verified
Journal Article
Closed access
EOEvgueni Ovtchinnikov
Evgueni Ovtchinnikov
RBRichard Brown
Richard Brown
CKChristoph Kolbitsch
Christoph Kolbitsch
EPEdoardo Pasca
Edoardo Pasca
CCCasper da Costa-Luis
Casper da Costa-Luis
KTKris Thielemans
Kris Thielemans

7 December 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SDSebastian Dietrich
Sebastian Dietrich
CAChristoph S. Aigner
Christoph S. Aigner
CKChristoph Kolbitsch
Christoph Kolbitsch
JMJohannes Mayer
Johannes Mayer
JLJuliane Ludwig
Juliane Ludwig
SSSebastian Schmitter
Sebastian Schmitter
Purpose: To introduce and investigate a method for free‐breathing three‐dimensional (3D) mapping of the human body at ultrahigh field (UHF), which can be used to generate homogenous flip angle (FA) distributions in the human body at UHF.Methods: A 3D relative mapping sequence with a radial phase‐encoding (RPE) k‐space trajectory was developed and applied in 11 healthy subjects at 7T. An RPE‐based actual flip angle mapping method was applied with a dedicated shim setting to calibrate the relative maps yielding absolute maps of the individual transmit channels. The method was evaluated in a motion phantom and by multidimensional in vivo measurements. Additionally, 3D gradient echo scans with and without static phase‐only shims were used to qualitatively validate shim predictions.Results: The phantom validation revealed good agreement for maps between dynamic measurement and static reference acquisition. The proposed 3D method was successfully validated in vivo by comparing magnitude and phase distributions with a 2D Cartesian reference. 3D maps free from visible motion artifacts were successfully acquired for 11 subjects with body mass indexes ranging from 19 kg/m2 to 34 kg/m2. 3D respiration‐resolved absolute maps indicated FA differences between inhalation and exhalation up to 15% for one channel and up to 24% for combined channels for shallow breathing.Conclusion: The proposed method provides respiration‐resolved absolute 3D maps of the human body at UHF, which enables the investigation and development of 3D shimming and parallel transmission methods to further enhance body imaging at UHF.

28 January 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SDSebastian Dietrich
Sebastian Dietrich
CAChristoph Stefan Aigner
Christoph Stefan Aigner
JMJohannes Mayer
Johannes Mayer
CKChristoph Kolbitsch
Christoph Kolbitsch
JSJeanette Schulz‐Menger
Jeanette Schulz‐Menger
SSSebastian Schmitter
Sebastian Schmitter
Purpose: Respiratory motion‐compensated (MC) 3D cardiac fat‐water imaging at 7T.Methods: Free‐breathing bipolar 3D triple‐echo gradient‐recalled‐echo (GRE) data with radial phase‐encoding (RPE) trajectory were acquired in 11 healthy volunteers (7M\4F, 21–35 years, mean: 30 years) with a wide range of body mass index (BMI; 19.9–34.0 kg/m2) and volunteer tailored shimming. The bipolar‐corrected triple‐echo GRE‐RPE data were binned into different respiratory phases (self‐navigation) and were used for the estimation of non‐rigid motion vector fields (MF) and respiratory resolved (RR) maps of the main magnetic field deviations (ΔB0). RR ΔB0 maps and MC ΔB0 maps were compared to a reference respiratory phase to assess respiration‐induced changes. Subsequently, cardiac binned fat‐water images were obtained using a model‐based, respiratory motion‐corrected image reconstruction.Results: The 3D cardiac fat‐water imaging at 7T was successfully demonstrated. Local respiration‐induced frequency shifts in MC ΔB0 maps are small compared to the chemical shifts used in the multi‐peak model. Compared to the reference exhale ΔB0 map these changes are in the order of 10 Hz on average. Cardiac binned MC fat‐water reconstruction reduced respiration induced blurring in the fat‐water images, and flow artifacts are reduced in the end‐diastolic fat‐water separated images.Conclusion: This work demonstrates the feasibility of 3D fat‐water imaging at UHF for the entire human heart despite spatial and temporal and B0 variations, as well as respiratory and cardiac motion.

21 January 2021 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
JMJohannes Mayer
Johannes Mayer
TWThomas-Heinrich Wurster
Thomas-Heinrich Wurster
TSTobias Schaeffter
Tobias Schaeffter
ULUlf Landmesser
Ulf Landmesser
AMAndreas Morguet
Andreas Morguet
CKChristoph Kolbitsch
Christoph Kolbitsch
Background: Cardiac PET has recently found novel applications in coronary atherosclerosis imaging using [18F]NaF as a radiotracer, highlighting vulnerable plaques. However, the resulting uptakes are relatively small, and cardiac motion and respiration-induced movement of the heart can impair the reconstructed images due to motion blurring and attenuation correction mismatches. This study aimed to apply an MR-based motion compensation framework to [18F]NaF data yielding high-resolution motion-compensated PET and MR images.Methods: Free-breathing 3-dimensional Dixon MR data were acquired, retrospectively binned into multiple respiratory and cardiac motion states, and split into fat and water fraction using a model-based reconstruction framework. From the dynamic MR reconstructions, both a non-rigid cardiorespiratory motion model and a motion-resolved attenuation map were generated and applied to the PET data to improve image quality. The approach was tested in 10 patients and focal tracer hotspots were evaluated concerning their target-to-background ratio, contrast-to-background ratio, and their diameter.Results: MR-based motion models were successfully applied to compensate for physiological motion in both PET and MR. Target-to-background ratios of identified plaques improved by 7 ± 7%, contrast-to-background ratios by 26 ± 38%, and the plaque diameter decreased by −22 ± 18%. MR-based dynamic attenuation correction strongly reduced attenuation correction artefacts and was not affected by stent-related signal voids in the underlying MR reconstructions.Conclusions: The MR-based motion correction framework presented here can improve the target-to-background, contrast-to-background, and width of focal tracer hotspots in the coronary system. The dynamic attenuation correction could effectively mitigate the risk of attenuation correction artefacts in the coronaries at the lung-soft tissue boundary. In combination, this could enable a more reproducible and reliable plaque localisation.

5 July 2021 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
RBRichard Brown
Richard Brown
CKChristoph Kolbitsch
Christoph Kolbitsch
CDClaire Delplancke
Claire Delplancke
EPEvangelos Papoutsellis
Evangelos Papoutsellis
JMJohannes Mayer
Johannes Mayer
KTKris Thielemans
Kris Thielemans
SIRF is a powerful PET/MR image reconstruction research tool for processing data and developing new algorithms. In this research, new developments to SIRF are presented, with focus on motion estimation and correction. SIRF’s recent inclusion of the adjoint of the resampling operator allows gradient propagation through resampling, enabling the MCIR technique. Another enhancement enabled registering and resampling of complex images, suitable for MRI. Furthermore, SIRF’s integration with the optimization library CIL enables the use of novel algorithms. Finally, SPM is now supported, in addition to NiftyReg, for registration. Results of MR and PET MCIR reconstructions are presented, using FISTA and PDHG, respectively. These demonstrate the advantages of incorporating motion correction and variational and structural priors. This article is part of the theme issue ‘Synergistic tomographic image reconstruction: part 2’.

10 May 2021 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
JMJohannes Mayer
Johannes Mayer
YJYining Jin
Yining Jin
TWThomas-Heinrich Wurster
Thomas-Heinrich Wurster
MMMarcus R. Makowski
Marcus R. Makowski
CKChristoph Kolbitsch
Christoph Kolbitsch
Coronary artery disease (CAD) is caused by the formation of plaques in the coronary arteries and is one of the most common cardiovascular diseases. NaF-PET can be used to assess plaque composition, which could be important for therapy planning. One of the main challenges of NaF-PET is cardiac and respiratory motion which can strongly impair diagnostic accuracy. In this study, we investigated the use of a synergistic image registration approach which combined motion-resolved MR and PET data to estimate cardiac and respiratory motion. This motion estimation could then be used to improve the NaF-PET image quality. The approach was evaluated with numerical simulations andin vivoscans of patients suffering from CAD. In numerical simulations, it was shown, that combining MR and PET information can improve the accuracy of motion estimation by more than 15%. For thein vivoscans, the synergistic image registration led to an improvement in uptake visualization. This is the first study to assess the benefit of combining MR and NaF-PET for cardiac and respiratory motion estimation. Further patient evaluation is required to fully evaluate the potential of this approach.This article is part of the theme issue ‘Synergistic tomographic image reconstruction: part 1’.