William Barone

William Barone

Auto-generated profile, based on publicly available information

William Barone

Musculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2012 in BJOG: An International Journal of Obstetrics & Gynaecology
Verified
Journal Article
Open access
PDF file
AFAndrew Feola
Andrew Feola
SAS Abramowitch
S Abramowitch
ZJZ Jallah
Z Jallah
SSS Stein
S Stein
WBW Barone
W Barone
PMP Moalli
P Moalli
Objective: To define the impact of prolapse mesh on the biomechanical properties of the vagina by comparing the prototype Gynemesh PS (Ethicon) to two new‐generation lower stiffness meshes, SmartMesh (Coloplast) and UltraPro (Ethicon).Design: A study employing a nonhuman primate model.Setting: University of Pittsburgh, PA, USA.Population: Forty‐five parous rhesus macaques.Methods: Meshes were implanted via sacrocolpopexy after hysterectomy and compared with sham. Because its stiffness is highly directional, UltraPro was implanted in two directions: UltraPro Perpendicular (less stiff) and UltraPro Parallel (more stiff), with the indicated direction referring to the position of the blue orientation lines relative to the longitudinal axis of the vagina. The mesh–vaginal complex (MVC) was excised in toto after 3 months.Main outcome measures: Active mechanical properties were quantified as the contractile force generated in the presence of 120 mmol/l KCl. Passive mechanical properties (a tissue's ability to resist an applied force) were measured using a multiaxial protocol.Results: Vaginal contractility decreased by 80% following implantation with the Gynemesh PS (P = 0.001), 48% after SmartMesh (P = 0.001), 68% after UltraPro Parallel (P = 0.001) and was highly variable after UltraPro Perpendicular (P = 0.16). The tissue contribution to the passive mechanical behaviour of the MVC was drastically reduced for Gynemesh PS (P = 0.003), but not for SmartMesh (P = 0.9) or UltraPro independent of the direction of implantation (P = 0.68 and P = 0.66, respectively).Conclusions: Deterioration of the mechanical properties of the vagina was highest following implantation with the stiffest mesh, Gynemesh PS. Such a decrease associated with implantation of a device of increased stiffness is consistent with findings from other systems employing prostheses for support.

1 September 2016 in American Journal of Obstetrics and Gynecology
Verified
Journal Article
Closed access
WBWilliam R. Barone
William R. Barone
PMPamela A. Moalli
Pamela A. Moalli
SASteven Abramowitch
Steven Abramowitch

11 August 2012 in International Urogynecology Journal
Verified
Journal Article
Closed access
PDF file
AFAndrew Feola
Andrew Feola
WBWilliam Barone
William Barone
PMPamela Moalli
Pamela Moalli
SASteven Abramowitch
Steven Abramowitch

20 August 2015 in BJOG: An International Journal of Obstetrics & Gynaecology
Verified
Journal Article
Open access
PDF file
ZJZ Jallah
Z Jallah
RLR Liang
R Liang
AFAndrew Feola
Andrew Feola
WBW Barone
W Barone
SPS Palcsey
S Palcsey
Pamela A. MoalliPamela A. Moalli
Pamela A. Moalli
Objective: To evaluate the impact of prolapse meshes on vaginal smooth muscle structure (VaSM) and function, and to evaluate these outcomes in the context of the mechanical and textile properties of the mesh.Design: Three months following the implantation of three polypropylene prolapse meshes with distinct textile and mechanical properties, mesh tissue explants were evaluated for smooth muscle contraction, innervation, receptor function, and innervation density.Setting: Magee‐Womens Research Institute at the University of Pittsburgh.Population: Thirty‐four parous rhesus macaques of similar age, parity, and pelvic organ prolapse quantification (POP–Q) scores.Methods: Macaques were implanted with mesh via sacrocolpopexy. The impact of Gynemesh™ PS (Ethicon; n = 7), Restorelle® (Coloplast; n = 7), UltraPro™ parallel and UltraPro™ perpendicular (Ethicon; n = 6 and 7, respectively) were compared with sham‐operated controls (n = 7). Outcomes were analysed by Kruskal–Wallis ANOVA, Mann–Whitney U–tests and multiple regression analysis (P < 0.05).Mean outcome measures: Vaginal tissue explants were evaluated for the maximum contractile force generated following muscle, nerve, and receptor stimulation, and for peripheral nerve density.Results: Muscle myofibre, nerve, and receptor‐mediated contractions were negatively affected by mesh only in the grafted region (P < 0.001, P = 0.002, and P = 0.008, respectively), whereas cholinergic and adrenergic nerve densities were affected in the grafted (P = 0.090 and P = 0.008, respectively) and non‐grafted (P = 0.009 and P = 0.005, respectively) regions. The impact varied by mesh property, as mesh stiffness was a significant predictor of the negative affect on muscle function and nerve density (P < 0.001 and P = 0.013, respectively), whereas mesh and weight was a predictor of receptor function (P < 0.001).Conclusions: Mesh has an overall negative impact on VaSM, and the effects are a function of mesh properties, most notably, mesh stiffness.Tweetable Prolapse mesh affects vaginal smooth muscle.

1 February 2017 in American Journal of Obstetrics and Gynecology
Verified
Journal Article
Closed access
RLRui Liang
Rui Liang
KKKatrina Knight
Katrina Knight
WBWilliam Barone
William Barone
RPRobert W. Powers
Robert W. Powers
ANAlexis Nolfi
Alexis Nolfi
PMPamela A. Moalli
Pamela A. Moalli

12 February 2016 in International Urogynecology Journal
Verified
Journal Article
Closed access
PDF file
KKKatrina M. Knight
Katrina M. Knight
PMPamela A. Moalli
Pamela A. Moalli
ANAlexis Nolfi
Alexis Nolfi
SPStacy Palcsey
Stacy Palcsey
WBWilliam R. Barone
William R. Barone
SASteven Abramowitch
Steven Abramowitch