Wei Zhang

Wei Zhang

Auto-generated profile, based on publicly available information

Wei Zhang

Department of Architecture and Civil Engineering, Zhejiang Tongji Vocational College of Science and Technology, Hangzhou, P.R. China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2024 in Archives of Electrical Engineering
Verified
Journal Article
Open access
PDF file
WZWei Zhang
Wei Zhang
XCXiaoqiang Chen
Xiaoqiang Chen
YWYing Wang
Ying Wang
In order to achieve energy savings and promote on-site integration of photovoltaic energy in electrified railways, a topology structure is proposed for the integration of photovoltaic (PV) and the energy storage system (ESS) into the traction power supply system (TPSS) based on a railway power conditioner (RPC). This paper analyzes the composition and operation principles of this structure. To assess the economic benefits brought by the integration of photovoltaic and energy storage systems, a bilevel optimization model is established, with the objectives of optimizing energy storage capacity configuration and photovoltaic energy integration. The KKT (Karush–Kuhn–Tucker) method is employed to transform the model into a single-layer mixed-integer linear programming model, which is then solved using the CPLEX solver in MATLAB. The research findings indicate that, with the configuration of the ESS, the optimal PV consumption rate achieved is 96.8749%. Compared to a 100% PV consumption rate, the ESS capacity configuration is reduced by 13.14%, and the overall operational cost of the TPSS is at its lowest. The study suggests that the proposed bilevel optimization algorithm can more effectively consider PV consumption, leading to enhanced economic performance of the TPSS operation.

3 June 2024 in Archives of Civil Engineering
Verified
Journal Article
Open access
PDF file
WZWei Zhang
Wei Zhang
Reclamation from the sea is a method of expanding urban area, but it also faces the problem of difficult treatment of soft soil foundation by hydraulic reclamation. Therefore, a soft soil consolidation method that combines vibration pressure boosting drainage and piled-load static pressure stacking is now proposed. To verify the effectiveness of this method, a consolidation test based on soft soil samples was designed and conducted in the study. The test results showed that when the sampling height was 240mm, the overall moisture content of the consolidated soil sample was the highest, 44.3%, and the consolidation effect was the worst. When the sampling height was 140mm, the overall moisture content obtained from the test was the lowest, 43.1%, and the consolidation effect was the best. The displacement of corner 2 and center point at the intersection of the preceding and following periods was greater, with values of 37.1 mm and 39.2 mm, respectively. At this point, the displacement of corner 1 was significantly smaller, at 30.9 mm. In the later loading stage, the slope of the vertical displacement curve significantly increased. When the experimental time reached 7000 min, the mixed method designed in this study had a drainage rate of 0.53 ml/min, which was significantly higher than other traditional methods. The experiment outcomes indicated that the method designed in this study had certain application potential for improving the consolidation effect of soft soil foundation in hydraulic fill sites.

3 November 2019 in International Journal of Electronics and Telecommunications
Verified
Journal Article
Closed access
PDF file
WZWei Zhang
Wei Zhang
ZLZhongqiang Luo
Zhongqiang Luo
XXXingzhong Xiong
Xingzhong Xiong
To overcome the detrimental influence of α impulse noise in power line communication and the trap of scarce prior information in traditional noise suppression schemes , a power iteration based fast independent component analysis (PowerICA) based noise suppression scheme is designed in this paper. Firstly, the pseudo-observation signal is constructed by weighted processing so that single-channel blind separation model is transformed into the multi-channel observed model. Then the proposed blind separation algorithm is used to separate noise and source signals. Finally, the effectiveness of the proposed algorithm is verified by experiment simulation. Experiment results show that the proposed algorithm has better separation effect, more stable separation and less implementation time than that of FastICA algorithm, which also improves the real-time performance of communication signal processing.

19 April 2024 in Archives of Thermodynamics
Verified
Journal Article
Open access
PDF file
WZWei Zhang
Wei Zhang
HJHuaqiao Jiang
Huaqiao Jiang
Based on the finite element simulation software ANSYS Workbench, this study reports the thermal characteristics of a high-speed motorized spindle. The temperature field distribution and axial thermal deformation of the motorized spindle are then detected on an experimental platform. A comparison between the experimental and simulation results revealed the temperature rise of the motorized spindle during the working process. Under steady-state conditions of the working mo-torized spindle, the temperatures of the front bearing, rear bearing and stator were determined as 20°C, approximately 30°C and 25°C, respectively. The axial thermal elongation of the motorized spindle is approximately 10 μm.

18 December 2023 in Archives of Metallurgy and Materials
Verified
Journal Article
Open access
PDF file
WZWei Zhang
Wei Zhang
GHGeorges Houlachi
Georges Houlachi
SHSanae Haskouri
Sanae Haskouri
EGEdward Ghali
Edward Ghali
In zinc electrowinning, small amounts of manganese ions additives are needed in the electrolyte to reduce the corrosion of anodes and minimize the contamination of cathodic zinc by dissolved lead. However, excess manganese oxide could cover the dimensionally stable anodes (DSA) surface and decrease their service life. Additives of phosphoric acid are put in the electrolyte to complex the manganic Mn3+ ion and hence reduce its disproportionation to MnO2. In the investigation, phosphoric acid was added to sulfuric acid or zinc electrolytes, and conventional and recent electrochemical measurements were carried out to examine electrochemical behaviour of DSA (Ti/IrO2-Ta2O5) anode during zinc electrolysis at 48 mA/cm2 and 39°C. It was observed that the anodic potentials of DSA anodes were lower by 27 mV after 5 h polarization in the zinc electrolyte containing 35 g/L phosphoric acid at 39°C. Electrochemical impedance measurements show that the addition of 35 ml/L H3PO4 to the zinc electrolyte can increase impedance resistances of the DSA mesh anodes. Cyclic voltammogram studies (CV) at a scan rate of 5 mV/s without agitation show that the oxidation peak in the solution with 35 ml/L phosphoric acid addition is highest, followed by that with 17 ml/L phosphoric acid addition and that without addition of phosphoric acid.

21 March 2025 in Archives of Civil Engineering
Verified
Journal Article
Open access
PDF file
WZWei Zhang
Wei Zhang
LLLei Lv
Lei Lv
XLXincheng Li
Xincheng Li
XOXinhong Ouyang
Xinhong Ouyang
ZFZhongqiu Fu
Zhongqiu Fu
Through the finite element method, the finite element models of three kinds of buckling-restrained brace components: cross-shaped square steel tube support, cross-shaped circular steel tube support, and circular steel tube support are established. The hysteretic performance of buckling-restrained braces under cyclic loading is analyzed, and the influence of component parameters on the mechanical performance of three kinds of buckling-restrained braces is further analyzed. The results show that the three types of buckling restrained braces have good hysteretic energy dissipation performance, and the cross-shaped square steel tube brace has the best hysteretic energy dissipation performance. The influence of the restraint stiffness ratio of the buckling-restrained brace on the mechanical properties of the three types of buckling-restrained braces is consistent.With the increase of the restraint ratio, the buckling-restrained brace reaches full-section yield. The increase of the width-thickness ratio of the inner core element will cause the yield lag of the buckling-restrained brace, while the lower width-thickness ratio of the inner core element will cause excessive stress concentration. Therefore, it is suggested that the width-thickness ratio of the inner core element should be between 5 and 10. The initial imperfection and connection stiffness of buckling-restrained braces have little effect on the bearing capacity of buckling-restrained braces.