Raul Ionel

Raul Ionel

Auto-generated profile, based on publicly available information

Raul Ionel

Politehnica University Timioara,Measurements and Optical Electronics Department,Timioara,Romania

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2014 in International Journal of Environmental Science and Technology
Verified
Journal Article
Closed access
PDF file
DDD. Dascălu
D. Dascălu
LPLaura Pitulice
Laura Pitulice
RIR. Ionel
R. Ionel
OBO. Bizerea-Spiridon
O. Bizerea-Spiridon

1 April 2006 in 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007
Verified
Conference Paper
Closed access
MPMircea Popa
Mircea Popa
RIRaul Ionel
Raul Ionel
VGVoicu Groza
Voicu Groza
MMMarius Marcu
Marius Marcu
The PC based virtual instrumentation is a dynamic and attractive alternative to the classic instrumentation. Its main advantages are: flexibility and adaptability, low cost, wide development of extension PC boards with measurements features, attractive representation of measurement results, in different forms, on the PC's monitor. The paper presents a system identification application with PC based (virtual) instrumentation. The virtual system is made of an external board, connected to the PC via the USB interface and a software tool, Agilent VEE (Visual Engineering Environment). The presented virtual system can work as a voltmeter, ammeter, signal generator, digital oscilloscope and power supply. The main contribution of the paper is the extension of the application domain of the virtual instrumentation system to system identification. The identification method consists of applying to the system input a binary pseudorandom signal (BPRS) and determining the impulse response of the system as being well approximated by the cross-correlation function between the input signal and the answer of the system. The application is intended for educational purposes but can be used in other areas too

10 May 2023
Verified
Conference Paper
Closed access
RIRaul Ionel
Raul Ionel
ADAnca-Ioana Dărăbuț
Anca-Ioana Dărăbuț
CCCătălin - Daniel Căleanu
Cătălin - Daniel Căleanu
This paper describes a Boundary Scan Test (BST, IEEE Std. 1149.1) test station designed and implemented with a requirement of full parallel evaluation for 8 Devices Under Test (DUTs). The suggested guidelines can function as reference for the implementation of an industrial BST station. This discussion is relevant due to the increasing prevalence of test systems utilizing this technology. By using XJTAG tools integrated with NI LabVIEW/TestStand, we emphasize the benefits of such a solution, deployed for production purposes, with respect to maximizing test coverage, reducing engineering implementation effort and costs. The added value of this work consists of several applicative research key elements. First, some considerations for building the BST test adapter (or test fixture) are discussed in relation to BST test requirements. Next, the software interface implementation flow, from a structural perspective, is explained. Finally, test procedures are presented with the observation that, besides the well-established BST procedures, the proposed implementation also serves as a DUT programming station. Experimental results, obtained after deployment for production purposes, confirm the benefits and reliability of such a solution.

1 May 2010
Verified
Conference Paper
Closed access
RIRaul Ionel
Raul Ionel
SISabin Ionel
Sabin Ionel
AIAlimpie Ignea
Alimpie Ignea
Constant improvement of leak detection techniques in pipe systems used for liquids transportation is a priority for companies and authorities around the world. If a pipe presents leakage problems, the liquid which is lost generates specific signals which are transmitted in the material of the pipe. These signals can be recorded using accelerometers. They are analyzed with the purpose of identifying the location of the leak. An important data analysis tool which helps in the process of leak position detection is the Cross Correlation Function (CCF). It is calculated between two simultaneously recorded specific leak signals with the purpose of time delay estimation. Time delay estimation calculations lead to the identification of the leak position. However, a traditional implementation of the CCF may not be satisfactory. Recorded signals are affected by noise coming from pipe elbows, junctions or traffic. All these unwanted noise sources can influence the aspect and accuracy of the CCF. Further improvements are necessary. This paper presents a Labview 8.5 implementation of an algorithm which improves the quality of the calculated CCF. Being part of a more complex software application, the algorithm uses the calculation of the coherence function. By analyzing the coherence the application will automatically select two frequency intervals (narrow bands) for filtering the leak signals. After the filtering process, the calculation of the CCF shows an increased quality. The application can be accessed from distance if a remote user needs to study or save the CCF results. No filtering settings are required and the method assures good results especially in the case of recorded signals which are highly affected by unwanted noise.