Selma Ferrer da Silva

Selma Ferrer da Silva

Auto-generated profile, based on publicly available information

Selma Ferrer da Silva

São Rafael Câmaras Frigoríficas Arujá São Paulo Brazil

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2026 in Packaging Technology and Science
Verified
Journal Article
Open access
SSSibele Maria Schuantes‐Paim
Sibele Maria Schuantes‐Paim
RLRenata Fabiana Leite
Renata Fabiana Leite
VCVictor Arayama Cruz
Victor Arayama Cruz
VGVanessa Ayres Carneiro Gonçalves
Vanessa Ayres Carneiro Gonçalves
JAJúlia Karini da Silva Araujo
Júlia Karini da Silva Araujo
BRBartira de Aguiar Roza
Bartira de Aguiar Roza
This study aimed to present and validate the Autonomous and Intelligent Packaging for the Cold Chain in Health Systems (EMAIS‐SR) for organ transport through an experimental model using porcine organs. To do so, Landrace porcine hearts, livers, pancreases and kidneys were transported using either EMAIS‐SR or traditional ice‐filled coolers. Following transport, organs were assessed after 2 h through collected data that included temperature monitoring, macroscopic evaluation, histological analysis and microbiological testing. Prototypes at different technology readiness levels (TRL6 and TRL7) were evaluated. Regarding the findings, EMAIS‐SR maintained organ temperatures predominantly within the recommended 2°C–8°C range. In the adjusted analysis, the TRL7 prototype achieved significantly lower post‐transport temperatures than TRL6 (adjusted difference: 2.91°C; 95% CI, 1.32–4.50; p = 0.0006), indicating improved thermal performance after system refinements. Additionally, minor macroscopic changes were observed in some samples, but without histological correlation. Histological analysis showed better tissue preservation in EMAIS‐SR samples, particularly in nuclei morphology and cytoplasmic structure. Furthermore, microbiological results indicated equivalent or lower contamination in EMAIS‐SR compared to the control, especially in later tests. Overall, EMAIS‐SR demonstrated effective thermal control, preservation of tissue integrity and biological safety in a structured preclinical model using porcine organs. Consequently, these findings validate EMAIS‐SR as a robust and clinically promising alternative to conventional organ transport systems.

1 January 2026 in Sao Paulo Medical Journal
Verified
Journal Article
Open access
FRFlavio Pola dos Reis
Flavio Pola dos Reis
PGPedro Henrique Andrade Guimarães
Pedro Henrique Andrade Guimarães
MFMatheus Werner Fantato
Matheus Werner Fantato
SSSelma Ferrer da Silva
Selma Ferrer da Silva
LRLiliane Moreira Ruiz
Liliane Moreira Ruiz
PPPaulo Manuel Pêgo-Fernandes
Paulo Manuel Pêgo-Fernandes
BACKGROUND: Intermediate temperatures (10°C) better preserve mitochondrial function and extend ischemic time, which are fundamental for lung preservation during transplantation. The EMAIS-SR device was developed as a reusable, cost-effective alternative to maintain the 10°C set-point, thereby overcoming logistical and economic barriers in organ transport. OBJECTIVE: This study aimed to validate the thermal stability of the EMAIS-SR system in a swine model by evaluating the organ-cooling curve and the time spent within the target temperature range. DESIGN AND SETTING: Validation study using experimental surgery on porcine organs. METHODS: Lung blocks were harvested from two Landrace swine in independent experiments (P1, P2). The organs were placed in triple sterile packaging. Thermal stability was monitored for 48 h by using four negative temperature coefficient (NTC) thermistors (three intrapulmonary and one extrapulmonary) with data acquisition at a 0.1-s interval. Another datalogger (Hantek ® HTM208B) was used for control and validation. Thermal distribution was further characterized by infrared thermography (FLIR C3-X). RESULTS: In Experiment 1 (P1), intrapulmonary temperatures reached the predefined target range (≤ 12°C) approximately 1.4 h after lung extraction, and the mean temperature recorded in the container was 8.01 °C (standard deviation, 2.88°C). In Experiment 2 (P2), a mean temperature reduction of 6.6°C was observed, bringing the intrapulmonary temperature to the target range (≤ 12°C) within approximately 2 h post-extraction. CONCLUSION: The EMAIS-SR device effectively maintained lung-preservation temperatures within the target 8°C–12°C range over 48 h. These results demonstrate the system’s technical feasibility and its capacity to provide consistent thermal stability across intrapulmonary compartments.