30 January 2018 in IEEE Transactions on Applied Superconductivity
The eventual goal of high-voltage direct-voltage (HVDC) systems is to implement HVDC grids. One of the key obstacles in realization of the HVDC grid is the absence of a dc circuit breaker (DCCB). Several prototypes of DCCBs for the HVDC grid have been proposed, but no commercial solution has been developed yet due to insufficient dc fault current breaking capabilities and an unreliable protection-coordination scheme. In this respect, application of the suitable fault current limiter is necessary, and the use of a superconducting fault current limiter (SFCL), which has already been developed for the ac grid, is a viable solution, but there is no fundamental research about performance evaluation of SFCLs for the dc grid. Therefore, we aim to verify the applicability of the conventional SFCL in HVDC grids and perform a comparative analysis of the performance of several types of SFCLs. To analyze the performance of the conventional SFCL in the HVDC grid, three well-known representative types of SFCLs are modeled in MATLAB/Simulink, and their current limiting and recovery characteristics and energy dissipation are examined in voltage-source converter HVDC system application. From the simulation results, we deduced the strengths and the weakness of different types of SFCLs. Consequently, the likely SFCL candidate for commercialization in dc grid applications is suggested.
16 March 2016 in IEEE Transactions on Applied Superconductivity
Recently, studies on HVDC circuit breaker (CB) prototypes have shown successful test results. Nevertheless, effective and reliable solutions regarding massive fault energy during dc fault interruption have not yet been commercialized, and dc current breaking topologies on methods of achieving artificial zero should be somewhat modified. As an alternative, one feasible solution is to combine fault current limiting technologies with dc breaking topologies. In this paper, we studied the application of resistive superconducting fault current limiters (SFCLs) on various types of HVDC CB in order to estimate the effects of combining fault current limiters and conventional dc breakers. For the simulation works, four types of dc breaker topologies were modeled, including a mechanical CB using black-box arc model, a passive resonance CB (PRCB), an inverse current injection CB, and a hybrid HVDC CB. In addition, a resistive SFCL was simulated and added to the dc breakers to verify its interruption characteristic and distributed energy across HVDC CB. From the simulation results, we found that the maximum fault current, interruption time, and dissipated energy stress on the HVDC CB could be decreased by applying SFCL. In addition, it was observed that, among four types of HVDC CB, PRCB with SFCL exhibited the best observable enhancement.
27 December 2018 in IEEE Access
Growing urbanization coupled with increased power demands have led to an increasing use of mixed power transmission lines with sections of overhead lines (OHL) and the underground cables. Due to differences in surge impedance of cables and OHL, voltage surges experience reflections and refractions at their boundaries which make the transient behavior of mixed high voltage direct current (HVDC) line quite peculiar. Lightning strikes on overhead sections of lines induce voltage surges that travel along OHL and enter the cable section. Lightning overvoltage can cause OHL insulators to flashover and stress cable insulation or cause its permanent breakdown. In this paper we simulated a fast front model of a mixed HVDC transmission line using an electromagnetic transient (EMT) simulation program (PSCAD) to analyze its transient behavior under a lightning strike. The leader progression model (LPM) has been used to predict the dielectric performance of OHL insulators. It has been shown that transition towers adjacent to the cable section are much less vulnerable to flashover than subsequent towers. The length of a riser section (connecting OHL and cable) and tower footing impedance have shown to significantly influence the flashover performance of OHL insulators. In addition, the length of cable segments and sheath grounding impedance have been found to influence cable overvoltage. This study can be used to evaluate the insulation coordination and overvoltage protection requirements for a mixed HVDC transmission line.
1 August 2019 in Physica C: Superconductivity and its Applications
18 June 2018 in IEEE Transactions on Power Delivery
To meet the growing power demand of the future, utilities and researchers have considered the addition of dc circuits in existing transmission corridors. The previous research has focused on analyzing the field environment, steady state induction and the negative effects of induction in the hybrid transmission lines. The overhead ground wires (OHGWs) have been used only for improving the lightning performance of overhead lines (OHL). In this paper, the spatial position of OHGWs have been studied with the objective of minimizing the steady state induction between power conductors as well as poorly grounded metallic objects like railroads and fences present near the ac-dc OHL. Candidate space for placement of OHGWs having shielding failure rate (SFR) of less than 4 is identified using the conventional electro-geometric model (EGM). The steady state induction in the power conductors and nearby metallic objects is studied as a function of position of OHGWs using electro-magnetic transient (EMT) simulation. The results indicate a strong correlation between the height of OHGWs and magnitude of induced voltage in power conductors, and metallic objects underneath the transmission line. The conscious effort in placement of OHGWs can reduce the magnitude of induced voltages while ensuring adequate lightning performance.