Kyu-Hoon Park

Kyu-Hoon Park

Auto-generated profile, based on publicly available information

Kyu-Hoon Park

Department of Electronic Engineering, Hanyang University, Hanyangdaehak-ro 55, Ansan 15588, Korea

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
HLHo-Yun Lee
Ho-Yun Lee
MAMansoor Asif
Mansoor Asif
KPKyu-Hoon Park
Kyu-Hoon Park
BLBang-Wook Lee
Bang-Wook Lee
The eventual goal of high-voltage direct-voltage (HVDC) systems is to implement HVDC grids. One of the key obstacles in realization of the HVDC grid is the absence of a dc circuit breaker (DCCB). Several prototypes of DCCBs for the HVDC grid have been proposed, but no commercial solution has been developed yet due to insufficient dc fault current breaking capabilities and an unreliable protection-coordination scheme. In this respect, application of the suitable fault current limiter is necessary, and the use of a superconducting fault current limiter (SFCL), which has already been developed for the ac grid, is a viable solution, but there is no fundamental research about performance evaluation of SFCLs for the dc grid. Therefore, we aim to verify the applicability of the conventional SFCL in HVDC grids and perform a comparative analysis of the performance of several types of SFCLs. To analyze the performance of the conventional SFCL in the HVDC grid, three well-known representative types of SFCLs are modeled in MATLAB/Simulink, and their current limiting and recovery characteristics and energy dissipation are examined in voltage-source converter HVDC system application. From the simulation results, we deduced the strengths and the weakness of different types of SFCLs. Consequently, the likely SFCL candidate for commercialization in dc grid applications is suggested.

8 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
KPKyu-Hoon Park
Kyu-Hoon Park
IKIl Kwon
Il Kwon
BLBang-Wook Lee
Bang-Wook Lee
The calculation of the continuous allowable current of an underground cable is determined by various characteristics. To calculate the allowable current in cables with alternating magnetic fields such as AC, special phenomena such as the proximity effect and skin effect must be applied. However, there are no standards or research related to the calculation of the continuous allowable current of a DC power cable that does not have an alternating magnetic field. In this paper, a quantitative DC cable continuous allowable current calculation formula of direct burial laying was derived by applying the existing AC cable continuous allowable current calculation method to the DC system. We developed a calculation tool that can calculate the continuous allowable current of DC cables using the derived formula. Assuming the cable conditions (cable specification, laying conditions, soil characteristics, arrangement, and number of strands, etc.), a continuous allowable current simulation of DC cables was performed. In addition, the level of contribution to the continuous allowable current value was analyzed by classifying the parameter categories into major and minor factors in the order of influence on the allowable current among the determined calculated parameters. As a result, the effectiveness of the DC cable continuous allowable current calculation tool derived by performing the allowable current calculation simulation was evaluated, and the allowable current calculation method of the HVDC cable was established.

1 October 2017
Verified
Conference Paper
Closed access
KPKyu-Hoon Park
Kyu-Hoon Park
HLHo-Yun Lee
Ho-Yun Lee
MAMansoor Asif
Mansoor Asif
BLBang-Wook Lee
Bang-Wook Lee
TSTae-Yong Shin
Tae-Yong Shin
CGChi-Wuk Gu
Chi-Wuk Gu
Many computational techniques which could analyze the behavior of electrical arc have been utilized to estimate the interrupting ability of the circuit breakers. Among them, black-box arc model has been known for valuable tool to simulate dynamic arc-circuit interactions during fault current interruption. Previous research works has shown that the black-box model was efficient tool to analyze AC arc characteristics especially for SF6 and air circuit breakers. But there's no noticeable investigations about the application of black box model to the DC circuit breakers, which is widely used in DC railway systems and DC microgrid. In this work, we tried to verify the validity of the applications of conventional AC black-box model to the DC electric arc. Several conventional arc models containing Cassie and Schwarz model were analyzed considering the tendency of the dc arcing current and voltage waveform using parametric sweep method. Simulation results showed that the weakness of current AC black-box model for DC arc analysis and compared that which model is more suitable for analyzing the DC arc.

18 June 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MAMansoor Asif
Mansoor Asif
HLHo-Yun Lee
Ho-Yun Lee
KPKyu-Hoon Park
Kyu-Hoon Park
BLBang-Wook Lee
Bang-Wook Lee
To meet the growing power demand of the future, utilities and researchers have considered the addition of dc circuits in existing transmission corridors. The previous research has focused on analyzing the field environment, steady state induction and the negative effects of induction in the hybrid transmission lines. The overhead ground wires (OHGWs) have been used only for improving the lightning performance of overhead lines (OHL). In this paper, the spatial position of OHGWs have been studied with the objective of minimizing the steady state induction between power conductors as well as poorly grounded metallic objects like railroads and fences present near the ac-dc OHL. Candidate space for placement of OHGWs having shielding failure rate (SFR) of less than 4 is identified using the conventional electro-geometric model (EGM). The steady state induction in the power conductors and nearby metallic objects is studied as a function of position of OHGWs using electro-magnetic transient (EMT) simulation. The results indicate a strong correlation between the height of OHGWs and magnitude of induced voltage in power conductors, and metallic objects underneath the transmission line. The conscious effort in placement of OHGWs can reduce the magnitude of induced voltages while ensuring adequate lightning performance.

5 November 2019 in Energies
Verified
Journal Article
Open access
PDF file
MAMansoor Asif
Mansoor Asif
HLHo-Yun Lee
Ho-Yun Lee
KPKyu-Hoon Park
Kyu-Hoon Park
ASAyesha Shakeel
Ayesha Shakeel
BLBang-Wook Lee
Bang-Wook Lee
Many geographical constraints and aesthetic concerns necessitate the partial use of cable sections in the High Voltage DC (HVDC) transmission line, resulting in a mixed transmission line. The overhead sections of mixed lines are exposed to lightning strikes. The lightning strikes can not only result in flashover of overhead line (OHL) insulators but can enter the cable and permanently damage its insulation if adequate insulation coordination measures are not taken. In this work, we have analyzed the factors that affect the level of overvoltage inside the cable by simulating a fast front model in PSCAD. It has been determined that surge arresters must be provided at cable terminals when the length of cable sections is less than 16 km to limit the core-ground overvoltage within the lightning impulse protective level (LIPL). The level of sheath-ground overvoltage is independent of the length of cable; however, it can be limited within LIPL by lowering the sheath grounding impedance to 1.2 Ω. Insulation coordination measures do not impact the likelihood of OHL insulators’ flashover. The flashover performance of OHL can be improved by lowering the footing impedance of the second tower closest to the cable terminals, which is otherwise most likely to flashover.

15 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
HLHo-Yun Lee
Ho-Yun Lee
MAMansoor Asif
Mansoor Asif
KPKyu-Hoon Park
Kyu-Hoon Park
HMHyun-Min Mun
Hyun-Min Mun
BLBang-Wook Lee
Bang-Wook Lee
The half bridge (HB) modular multilevel converter (MMC) technology is considered a breakthrough to mitigate the shortcomings of the conventional voltage source converter (VSC) in high-voltage direct-current (HVDC) grid application. However, interruption of the DC fault is still a challenge due to fast di/dt and extremely high levels of DC fault current. The fault interruption using a DC circuit breaker (DCCB) causes enormous energy dissipation and voltage stress across the DCCB. Therefore, the use of a fault current limiter is essential, and the superconducting fault current limiter (SFCL) is the most promising choice. Past literature has focused on the operating characteristics of DCCB or limiting characteristics of the SFCL. However, there is little understanding about the fault interruption and system recovery characteristics considering both DCCB and SFCL. In this paper, we have presented a comparative study on fault interruption and system recovery characteristics considering three types of fault limiting devices in combination with circuit breaker. The transient analyses of AC and DC system have been performed, to suggest the most preferable protection scheme. It has been concluded that, amongst the three fault limiting devices, the Hybrid SFCL in combination with circuit breaker, delivers the most desirable performance in terms of interruption time, recovery time, energy dissipation and voltage transients.