1 April 2022 in Review of Scientific Instruments
In this paper, we report the development of off-axis spiral phase mirrors that can be used to generate optical vortices from a range of millimeter waves. An obliquely incident Gaussian beam is reflected from a spiral phase mirror and is converted into an optical vortex beam with a desired topological charge. The mirrors were fabricated by mechanical machining. The designed vortex properties of reflected waves were investigated experimentally by using a low-power test, where the designed topological charge was verified based on the interference pattern between a vortex beam and a Gaussian-like beam. The designed topological charge was also estimated by using a phase retrieval method specialized for a vortex beam. These off-axis spiral phase mirrors can be used for propagation experiments of radio frequency waves with helical wavefronts in magnetized plasma.
4 April 2019 in Fusion Engineering and Design
1 March 2021 in Review of Scientific Instruments
A six-pole Q-band waveguide filter with a notch frequency above the Q-band has been developed for plasma diagnostics. The previous paper [Nishiura et al., J. Instrum. 10, C12014 (2015)] reported that the notch frequency exists within the standard band. In this study, the newly required notch filter extends the function, which prevents a thorny wave from being mixed into an instrument beyond the standard bandwidth of the waveguide. The mode control technique for cavities realizes a deep and sharp filter shape for Q-band notch filters with 56 and 77 GHz notches, respectively. The former filter has an attenuation more than 50 dB at 56.05 GHz and a bandwidth of 1.1 GHz at −3 dB. The latter filter has an attenuation more than 55 dB at 76.95 GHz and a bandwidth of 1.6 GHz at −3 dB. The electron cyclotron emission imaging and the electron cyclotron emission (ECE) diagnostics for the Q-band implemented a pair of the fabricated filters and demonstrated the ECE measurement successfully in the intense stray radiation from a 56 GHz gyrotron.
12 March 2015 in EPJ Web of Conferences
Until 2009, three high-power, over 1MW each, 77GHz gyrotrons have been installed and applied to the LHD experiment. In addition, a 154GHz gyrotron of 1MW was installed in 2012. The 77GHz gyrotrons suffer gradual increases of internal pressure during long-pulse operation delivering power to LHD. To mitigate the problem, quasi-steady operation by combination of on-off operations of the 77GHz gyrotrons was performed. Applying two 77GHz gyrotrons alternately with intervals of two minutes and an 84GHz gyrotron continuously, a 30 min. long-pulse discharge with the line average electron density n e_ave of 0.7×1019m−3 and the central electron temperature T e0 of 1.7keV was achieved by the time average injection power P inj of 260kW in 2012, showing significant progress in sustained density from the former 65 min. discharge with n e_ave of 0.15×1019m−3 and T e0 of 1.7keV by P inj of 110kW of 84GHz wave. In 2013, one of the 77GHz gyrotron was improved to furnish a sub-window to remove stray radiation inside the tube. And the new 154GHz gyrotron was applied to the long-pulse discharge experiment. Using three gyrotrons: 154, the improved and an existing 77GHz with P inj of 340kW in total, higher temperature plasma having steep temperature gradient typical for internal transport barrier, with n e_ave of 1.1×1019m−3 and T e0 of 3.5keV was quite stably sustained for 325s.
1 January 2013 in Plasma and Fusion Research
To establish a method for suppressing the spurious radiation that interferes with collective Thomson scattering measurements with less degradation of the main mode output power, the frequency evolution, and the output power of the megawatt 77-GHz gyrotron were measured during operation under optimized parameters. According to a mode competition calculation, the main mode output power may be increased by setting a lower gyrotron anode voltage at a higher magnetic field strength in the gyrotron resonator. Although the output power increased from 300kW to 530kW without any spurious radiation when the optimized operational parameters were used, the output power was about 50% of that at a lower magnetic field strength, and thus the output pulse width was limited to 60 ms. When an approach using the optimized operational parameters and a PIN switch was applied, the output power increased to 800kW without any harmful spurious radiation effect and the pulse width was expanded to 2 s. © 2013 The Japan Society of Plasma Science and Nuclear Fusion Research
12 March 2015 in EPJ Web of Conferences
In a high power Electron Cyclotron Resonance Heating (ECRH) system, a long-distance and low-loss transmission system is required to realize effective heating of nuclear fusion-relevant plasmas. A millimeter-wave beam position and profile monitor, which can be used in a high-power, evacuated, and cooled transmission line, is proposed, designed, manufactured, and tested. The beam monitor consists of a reflector, Peltier-device array and a heat-sink. It was tested using simulated electric heater power or gyrotron output power. The data obtained from the monitor were well agreed with the heat source position and profile. The methods of data analysis and mode-content analysis of a propagating millimeter-wave in the corrugated wave-guide are proposed.