16 June 2022 in Nuclear Fusion
Controlled particulate injections from the PPPL impurity powder dropper (IPD) into the Large Helical Device have demonstrated positive effects on the wall conditions on both an intra and inter-shot basis. Injections over a range of densities, input powers, pulse lengths, heating schemes, injection quantities and main ion species show conclusive evidence of improvement to plasma wall conditions. Successful injections are confirmed by both spectroscopic measurements as well as real-time visible camera signals. In 7 s long plasmas the responses include a reduction in wall recycling as well as a reduction in native impurity content as observed over the course of several discharges. For plasmas longer than 40 s, improvements to the recycling rate and increased impurity control are observed in real time as a consequence of the extended particulate injections. These experiments demonstrate the extended applicability of this solid particulate conditioning technique to the control and maintenance of the plasma wall conditions. In addition they are an important initial step in the development of the real-time boronization technique as a supplement to standard conditioning scenarios.
1 January 2007 in Plasma and Fusion Research
An overview of the research and development of imaging bolometers giving a perspective on the applicability of this diagnostic to a fusion reactor is presented. Traditionally the total power lost from a high temperature, magnetically confined plasma through radiation and neutral particles has been measured using one dimensional arrays of resistive bolometers. The large number of signal wires associated with these resistive bolometers poses hazards not only at the vacuum interface, but also in the loss of electrical contacts that has been observed in the presence of fusion reactor levels of neutron flux. Imaging bolometers, on the other hand, use the infrared radiation from the absorbing metal foil to transfer the signal through the vacuum interface and out from behind a neutron shield. Recently a prototype imaging bolometer known as the InfraRed imaging Video Bolometer has been deployed on the JT-60U tokamak which demonstrates the ability of this diagnostic to operate in a reactor environment. The application of computed tomography demonstrates the ability of one imaging bolometer with a semi-tangential view to produce images of the plasma emissivity. In addition, new detector foil development promises to strengthen the foil and increase the sensitivity by an order of magnitude
16 January 2013 in Journal of Nuclear Materials
1 July 2013 in Journal of Nuclear Materials
26 January 2009 in Journal of Nuclear Materials
12 March 2015 in EPJ Web of Conferences
Until 2009, three high-power, over 1MW each, 77GHz gyrotrons have been installed and applied to the LHD experiment. In addition, a 154GHz gyrotron of 1MW was installed in 2012. The 77GHz gyrotrons suffer gradual increases of internal pressure during long-pulse operation delivering power to LHD. To mitigate the problem, quasi-steady operation by combination of on-off operations of the 77GHz gyrotrons was performed. Applying two 77GHz gyrotrons alternately with intervals of two minutes and an 84GHz gyrotron continuously, a 30 min. long-pulse discharge with the line average electron density n e_ave of 0.7×1019m−3 and the central electron temperature T e0 of 1.7keV was achieved by the time average injection power P inj of 260kW in 2012, showing significant progress in sustained density from the former 65 min. discharge with n e_ave of 0.15×1019m−3 and T e0 of 1.7keV by P inj of 110kW of 84GHz wave. In 2013, one of the 77GHz gyrotron was improved to furnish a sub-window to remove stray radiation inside the tube. And the new 154GHz gyrotron was applied to the long-pulse discharge experiment. Using three gyrotrons: 154, the improved and an existing 77GHz with P inj of 340kW in total, higher temperature plasma having steep temperature gradient typical for internal transport barrier, with n e_ave of 1.1×1019m−3 and T e0 of 3.5keV was quite stably sustained for 325s.