Tina Puthen Purayil

Tina Puthen Purayil

Auto-generated profile, based on publicly available information

Tina Puthen Purayil

Manipal Academy of Higher Education, India

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Oral Biology and Craniofacial Research
Verified
Journal Article
Closed access
PSPrajwal Shetty
Prajwal Shetty
TPTina-Puthen Purayil
Tina-Puthen Purayil
KGKishore Ginjupalli
Kishore Ginjupalli
KPKalyana Chakravarthy Pentapati
Kalyana Chakravarthy Pentapati

1 January 2020 in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
Verified
Journal Article
Open access
PDF file
SBSwastika Bhattacharya
Swastika Bhattacharya
TPTina Puthen Purayil
Tina Puthen Purayil
KGKishore Ginjupalli
Kishore Ginjupalli
SKSandya Kini
Sandya Kini
SPSwathi Pai
Swathi Pai
Objective: To compare the color stability of Cention N, Fuji IX GP Extra, and Fuji IX GP after thermocycling. Material and Methods: Ten discs of each material of dimension 10 x 1 mm were prepared using a split mold. The preparations of the specimens were done according to the powder/liquid ratio as recommended by the manufacturers [4.6:1, 3.4:1 and 3.6:1 for the groups I, II, and III, respectively]. After setting, the samples were retrieved, and the thickness of each specimen was measured using a micrometer at five different locations. The specimens with variations in thickness, porosity or cracks were discarded and thus not included in the study. The selected specimens were stored in distilled water for 24 hours prior to testing. The prepared specimens were thermocycled at 5°C and 55°C, with a dwell time of 15 seconds for 250 or 500 cycles. Subsequently, the color parameters of the discs were measured using a spectrophotometer. The data were analyzed using two way ANOVA test, and a p-value <0.001 was considered. Results: Thermocycling resulted in changes in the color of both Glass Ionomer cement and Cention N (p<0.001). Among the materials tested, Cention N showed superior color stability. Conclusion: Cention N exhibited better color stability compared to Glass ionomer cements.

1 January 2016 in Journal of Conservative Dentistry
Verified
Journal Article
Open access
PDF file
AKArchit Kedia
Archit Kedia
VSVidya Saraswathi
Vidya Saraswathi
TPTina Puthen Purayil
Tina Puthen Purayil
VBVasudev Ballal
Vasudev Ballal
ASAakriti Saini
Aakriti Saini
Introduction: Accurate determination of working length (WL) is a critical factor for endodontic success. This is commonly achieved using an apex locator which is influenced by the presence or absence of the apical constriction. Hence, this study was done to compare the accuracy of two generations of apex locators in teeth with simulated apical root resorption. Materials and Methods: Forty maxillary central incisors were selected and after access preparation, were embedded in an alginate mold. On achieving partial set, teeth were removed, and a 45° oblique cut was made at the apex. The teeth were replanted and stabilized in the mold, and WL was determined using two generations of apex locators (Raypex 5 and Apex NRG XFR). Actual length of teeth (control) was determined by visual method. Statistical Analysis: Results were subjected to statistical analysis using the paired t-test. Results: Raypex 5 and Apex NRG was accurate for only 33.75% and 23.75% of samples, respectively. However, with ±0.5 mm acceptance limit, they showed an average accuracy of 56.2% and 57.5%, respectively. There was no significant difference in the accuracy between the two apex locators. Conclusion: Neither of the two apex locators were 100% accurate in determining the WL.

18 May 2023 in F1000Research
Verified
Journal Article
Open access
PDF file
ACAnindita Chakraborty
Anindita Chakraborty
TPTina Purayil
Tina Purayil
KGKishore Ginjupalli
Kishore Ginjupalli
KPKalyana Chakravarthy Pentapati
Kalyana Chakravarthy Pentapati
NSNeetha Shenoy
Neetha Shenoy
Background: To compare the surface roughness and microhardness of Ceram.x® SphereTEC™ one and Filtek Z350 XT after in-office bleaching with Pola office. Methods: Twenty samples each of (10 mm diameter and 2 mm height) Ceram.x® SphereTEC™ one and Filtek Z350 XT were prepared. The samples were subjected to three bleaching sessions with 35% hydrogen peroxide (Pola office) with a seven-day interval between each session. Surface roughness and microhardness of the prepared samples prior to and after the bleaching regimen were measured using a profilometer and Vickers hardness tester, respectively. Results: A significant reduction (p <0.001) in the surface hardness of Filtek Z350 XT from 27.67 ± 2.10 to 17.83 ± 1.36 Vickers hardness number (VHN) was observed after the bleaching whereas no significant reduction in surface hardness was observed with Ceram.x® SphereTEC™ one. The adjusted mean (estimated marginal mean) microhardness after bleaching for Ceram.x ® SphereTEC™ one (35.79 ± 1.45) was significantly higher than Filtek Z350 XT (19.54 ± 1.45) (p < 0.001). However, in-office bleaching of these materials did not significantly alter their surface roughness. Conclusions: In office-bleaching with 35% hydrogen peroxide can reduce the microhardness of nanofilled composite. However, the surface roughness was not influenced by the bleaching procedure in both nanohybrid and nanofilled composite resin materials.

1 February 2017 in World Journal of Dentistry
Verified
Journal Article
Open access
SUSree Theja Upadhyay
Sree Theja Upadhyay
TPTina Puthen Purayil
Tina Puthen Purayil
Aim To evaluate and compare the effect of epoxy resin-based sealer and a pozzolan-based mineral trioxide aggregate (MTA) sealer on the fracture resistance of endodontically treated teeth. Materials and methods Thirty single-rooted mandibular premolars were decoronated to a standardized root length of 15 mm. ProTaper rotary files up to a master apical file size of F3 were used for cleaning and shaping the root canals followed by 2.5% sodium hypochlorite irrigation. The teeth were randomly divided into three groups (n = 10 each), and the obturation was completed using gutta-percha with Endoseal MTA (group I) and AH Plus (group II) as root canal sealers. Group III served as control (instrumented and unfilled). Each specimen was then subjected to fracture testing by using a universal testing machine at a crosshead speed of 1.0 mm/minute until fracture. The force required to fracture each specimen was recorded and the data were subjected to statistical analysis using one-way analysis of variance (ANOVA), followed by pairwise comparison using post hoc Games-Howell test (p < 0.05). Results The fracture resistance of groups I and II were significantly higher than those of group III. No significant difference in the fracture resistance was observed between group I (Endoseal MTA) and group II (AH Plus) groups. Conclusion It can be concluded that the new root canal sealer, Endoseal MTA, is able to reinforce the tooth against fracture as good as AH Plus. Clinical significance Endoseal MTA is a sealer for the reinforcement of endodontically treated teeth. How to cite this article Upadhyay ST, Purayil TP, Ginjupalli K. Comparative evaluation of Fracture Resistance of EndodonticallyTreated Teeth Obturated with Pozzolan-based MTA Sealer and Epoxy Resin-based Sealer: An in vitro Study. World J Dent 2017;8(1):37-40.

1 January 2022 in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
Verified
Journal Article
Open access
PAPattath Kunjan Anju
Pattath Kunjan Anju
TPTina P. Purayil
Tina P. Purayil
KGKishore Ginjupalli
Kishore Ginjupalli
VBVasudev Ballal
Vasudev Ballal