Max Schoenen

Max Schoenen

Auto-generated profile, based on publicly available information

Max Schoenen

Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University Medical Faculty, Pauwelsstraße 20, Aachen, 52074, GERMANY

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2023 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Open access
CTChiara Turrina
Chiara Turrina
MSMax Schoenen
Max Schoenen
DMDavide Milani
Davide Milani
AKAnna Klassen
Anna Klassen
DGDiana M. Rojas Gonzaléz
Diana M. Rojas Gonzaléz
Sebastian SchwamingerSebastian Schwaminger
Sebastian Schwaminger
Coated iron oxide nanoparticles (IONs) are promising candidates for various applications in nanomedicine, including imaging, magnetic hyperthermia, and drug delivery. The application of IONs in nanomedicine is influenced by factors such as biocompatibility, surface properties, agglomeration, degradation behavior, and thrombogenicity. Therefore, it is essential to investigate the effects of coating material and thickness on the behavior and performance of IONs in the human body. In this study, IONs with a carboxymethyl dextran (CMD) coating and two thicknesses of silica coating (TEOS0.98, and TEOS3.91) were screened and compared to bare iron oxide nanoparticles (BIONs). All three coated particles showed good cytocompatibility (>70%) when tested with smooth muscle cells over three days. To investigate their potential long term behavior inside the human body, the Fe2+ release and hydrodynamic diameters of silica-coated and CMD (carboxymethyl dextrane)-coated IONs were analyzed in simulated body fluids for 72 h at 37 °C. The ION@CMD showed moderate agglomeration of around 100 nm in all four simulated fluids and dissolved faster than the silica-coated particles in artificial exosomal fluid and artificial lysosomal fluid. The particles with silica coating agglomerated in all tested simulated media above 1000 nm. Increased thickness of the silica coating led to decreased degradation of particles. Additionally, CMD coating resulted in nanoparticles with the least prothrombotic activity, and the thick silica coating apparently decreased the prothrombotic properties of nanoparticles compared to BIONs and ION@TEOS0.98. For magnetic resonance applications, ION@CMD and ION@TEOS3.91 showed comparatively high relaxation rates R2 values. In magnetic particle imaging experiments ION@TEOS3.91 yielded the highest normalized signal to noise ratio values and in magnetic hyperthermia studies, ION@CMD and ION@TEOS0.98 showed similar specific loss power. These findings demonstrate the potential of coated IONs in nanomedicine and emphasize the importance of understanding the effect of coating material and thickness on their behavior and performance in the human body.

23 July 2024 in Nanoscale Advances
Verified
Journal Article
Open access
PDF file
YLYanchen Li
Yanchen Li
RZRui Zhang
Rui Zhang
RBRoman Barmin
Roman Barmin
ERElena Rama
Elena Rama
MSMax Schoenen
Max Schoenen
RPRoger M. Pallares
Roger M. Pallares
Superparamagnetic iron oxide nanoparticles (SPIONs) are widely used for biomedical applications, including magnetic particle imaging (MPI) and magnetic hyperthermia. The co-precipitation method is one of the most common synthetic routes to obtain SPIONs, since it is simple and does not require extreme conditions, such as high temperatures. Despite its prevalence, however, the co-precipitation synthesis presents some challenges, most notably the high batch-to-batch variability, as multiple factors can influence nanoparticle growth. In this study, we utilized a fractional factorial design of experiments to identify key factors influencing SPION growth, properties, and performance in MPI and magnetic hyperthermia, namely Fe3+ content, pH, temperature, stirring, and atmosphere. Notably, our study unveiled secondary interactions, particularly between temperature and Fe3+ content, as well as pH and Fe3+ content, for which simultaneous changes of both parameters promoted greater effects than the sum of each factor effect alone, emphasizing the impact of synergistic effects on SPION growth and performance. These findings provide a deeper understanding of the growth mechanism of SPIONs, reconcile discrepancies in the existing literature, and underscore the importance of characterizing secondary interactions to improve the performance of SPIONs for biomedical applications.

11 April 2025 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
MSMax Schoenen
Max Schoenen
TSThomas Schmitz-Rode
Thomas Schmitz-Rode
ISIoana Slabu
Ioana Slabu
Magnetic hyperthermia-based therapies depend on heating performances of magnetic nanoparticles (MNP). Beyond specific MNP properties, dipole-dipole interactions resulting from the formation of MNP assemblies have a pivotal influence on heating performance. There is, however, limited understanding of the range of attributable negative and positive effects. Numerical simulations were used to unravel the effect of various spherical, elongated assemblies as well as MNP chains on heating performance. An advancing front assembly generating method was combined with a stochastic Langevin simulation. Experimental values of a hyperthermia application to destroy hollow organ tumours with heatable stent fibres were used to validate simulation results. Limited impact of assembly size on the heating performance was observed, whereas assembly geometry was crucial. Spherical assemblies lead to a decrease in specific loss power while elongated assemblies and chains yielded up to eightfold increase compared to randomly dispersed MNP. The heating performance of elongated assemblies and chains was dependent on their major-minor axes ratios, excitation field amplitude and assembly orientation relative to the field direction. The simulations unravelled that chains dominated the heating of stent fibres. The simulation is a valuable and versatile tool for the optimization of heating output of all sorts of MNP, which undergo structural changes in interaction with artificial and biological surroundings. This capability is demonstrated for fibre-based implants with incorporated MNP. Comparison between simulation and experiments demonstrates the susceptibility to the design of MNP assemblies. Precise information about assembly geometry is crucial to improve the prediction accuracy.

23 September 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MSM Schoenen
M Schoenen
LGL Göpfert
L Göpfert
BBBenedict Bauer
Benedict Bauer
CECaroline Emonts
Caroline Emonts
TGThomas Gries
Thomas Gries
ISIoana Slabu
Ioana Slabu
Objective. Magnetic particle imaging (MPI) opens huge possibilities in image-guided therapy. Its effectiveness is strongly influenced by the quality of the magnetic nanoparticles (MNP) used as tracers. Besides MNP optimisation following different synthesis routes, MNP assembly into linear structures can significantly enhance their performance in MPI. The present study investigates the influence of linear MNP structures on MPI signal for different MNP types. With regard to theranostic applications the role of linear structures in hybrid stent imaging is explored. Approach. Three MNP types were used to create linear MNP structures. MNP respectively the MNP structures were immobilised in a hydrogel and positioned at various orientations relative to the coordinate system of the MPI. A multi-channel reconstruction approach was applied to assess the orientation-specific signal. The insights gained were used to reconstruct a fibre-based polymer stent with incorporated linear structures. Main results. Different linear structure orientations could be delineated and visualised in multi-colour images. Linear structures orientated parallel to the direction of a magnetic excitation field lead to the highest signal intensities and peak positions of MPI frequency spectra were located near multiples of the frequency of the excitation coil. Image reconstructions of the stent were very sensitive to the orientation of linear structures within the fibres. Significance. This study reveals that the assembly of MNP results in non-linear contributions to the MPI signal. Consequently, the MPI signal intensity is not as usual merely linearly correlated with MNP concentration increasing the complexity in image reconstruction. The findings demonstrate the necessity of accounting for MNP structure orientation in image reconstruction. They also reveal the high potential of MPI to detect different MNP types and structures. Linear structures cause either significant signal reduction or signal increase depending on the angular position of the linear structures relative to the direction of MPI magnetic fields.