Chang Lu

Chang Lu

Auto-generated profile, based on publicly available information

Chang Lu

School of Civil and Environment Engineering, Harbin Institute of Technology Shenzhen, Shenzhen, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZLZuohua Li
Zuohua Li
YGYunxuan Gong
Yunxuan Gong
XGXiaoqian Gong
Xiaoqian Gong
NLNanxi Liu
Nanxi Liu
CLChang Lu
Chang Lu
JTJun Teng
Jun Teng
The stress fields of steel members in service are unevenly distributed under complicated loads. The existing single path ultrasonic (SPU) sensors can only measure stress in a single measurement point and direction. Multiple operations of the SPU sensors are required to measure stress at different measuring points and directions. The approach has low measurement efficiency and increases the measurement deviations caused by multiple operations. In this study, a modified method using an ultrasonic array sensor to measure the non-uniform absolute stress field of steel members was proposed. The relationship between the acoustic time differences of the longitudinal critically refracted (LCR) waves and the plane stress field was revealed in this method. The acoustoelastic equations of the three directional acoustic time differences and the plane principal stresses were derived. An innovative ultrasonic array non-uniform absolute stress field measurement scheme was designed, which integrated an ultrasonic array sensor capable of transmitting and receiving five LCR waves. Nineteen sets of acoustic time differences were measured by arranging the array sensor in the 0°, 45°, and 90° directions. Finally, the acoustic time differences were decoupled simultaneously to solve the acoustoelastic equation, thus achieving a non-uniform absolute stress field measurement of the steel member in service. The verification experiment indicates that the relative deviations of measurement stresses between the array sensor and strain gauges are less than 10%. Furthermore, the measurement accuracy and efficiency of the array sensor are higher than those of the SPU-LCR wave method and SPU-shear wave method, validating that the array sensor can rapidly and accurately measure the non-uniform absolute stress field of steel members.