In this paper, we design a monolithic integrated micro-opto-electromechanical system(MOEMS) accelerometer based on the Michelson interferometer structure. The accelerometer realizes the on-chip integration of the mode spot converter, the sensing optical path, the phase modulator and the photonic crystal reflector, and it senses the external acceleration through a “three-beam” structure which is composed of a central support beam and two tiny beams. The push-pull structure eliminates the coupling crosstalk caused by paraxial acceleration. Accurate results are demonstrated as follows: an accelerometer mechanical sensitivity of 3.638 nm/g, with a resonance frequency of 1742.2 Hz and a linear measurement range of ± 500 g, corresponding to a foot print of the core part with 960 μm×600 μm. With its high precision, large measurement range, and small size, the proposed accelerometer may pave the way for the applications in civil, industrial and military fields.
1 August 2023 in IEEE Photonics Technology Letters
In recent years, anti-resonant hollow-core fibers (known as AR-HCFs) have gradually become one of the research hotspots. However, their loss and birefringence properties are often difficult to reconcile. In this letter, a new structure of AR-HCF is proposed by analyzing the factors that affect their loss and birefringence. The fiber features a negative curvature core surround, double-layer structures, and two half-tubes containing nested tubes. Based on COMSOL Multiphysics, the designed AR-HCF has a high birefringence of $1.3\times 10 ^{-4}$ and a low confinement loss of 6.1 dB $\cdot $ km−1 at 1550 nm, a bandwidth of 40 nm, bending resistance and single-mode operation.
14 October 2018 in Journal of Lightwave Technology
In this paper, we theoretically analyze the wavelength temperature stability of multifunctional integrated optical chips (MIOCs) applied on fiber optic gyroscopes (FOGs). This study is critical for improving the temperature stability of the FOG scale factor, which is a significant parameter used to evaluate the dynamic characteristics of FOGs. Analytical and multiphysics simulations uncover two significant new predictions. First, changes in environmental temperature can lead to misalignment of the coupling structure between the chip and fiber, which is the main reason for the deterioration of the MIOC wavelength temperature stability. Second, misalignment caused by temperature changes is related to the initial alignment parameters of the coupling structure. Therefore, we can effectively improve the wavelength temperature stability of an MIOC by correctly choosing the initial alignment state of the coupling structure. Space coupling experiments are also presented to verify these predictions, and the experimental and simulation results are in good agreement.
We propose a monolithic integrated cavity optomechanical accelerometer based on push-pull photonic crystal zipper cavity. The accelerometer integrates grating couplers, phase modulators, acceleration sensing unit, and electrostatic force feedback module on a chip. We use push-pull structure to eliminate the coupling crosstalk caused by paraxial acceleration and extend its range using electrostatic force feedback module. The transmissive photonic crystal zipper cavity structure is adopted to improve the integration and stability of the system. Accurate results are demonstrated as follows: the bandwidth is larger than 20 kHz, the mechanical sensitivity is 369 pm/g, the measuring range is ±100 g, and the noise equivalent acceleration is 5.06 μg / Hz. With its advantages, the accelerometer can be used in consumer electronics, aerospace, resource exploration, and other fields.
In this paper, we proposed a hollow-core photonic crystal fiber (HCPCF) ring resonator based on a spatial coupling method, and the component is only 22×30×6mm 3 . When using a 7-core photonic crystal fiber with a mode field diameter of 10um, a ring resonator with the measured finesse of 18 can be built, indicating that the coupling loss is as low as 0.41dB. Compact and low-loss closed resonator is accomplished using a highly integrated free space silicon optical bench manufactured by deep silicon etching and tiny optical lens package technology, which promotes the practicality of the HCPCF gyro. In addition, two important factors affecting the spatial optical coupling efficiency, the lens type and the fiber mode field size, are investigated in this paper. The obtained results are instructive for all spatial optical coupling systems.