Sergey M. Korobeynikov

Sergey M. Korobeynikov

Auto-generated profile, based on publicly available information

Sergey M. Korobeynikov

Power Engineering Faculty, Novosibirsk State Technical University, Novosibirsk, Russia

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2021 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MLM. Lyutikova
M. Lyutikova
SKS. Korobeynikov
S. Korobeynikov
AKA. Konovalov
A. Konovalov
This article discusses the possibility of enhancing the insulating characteristics of a mineral oil-based on petroleum with high aromatic hydrocarbon content (23%) by mixing it with the synthetic ester Midel 7131. An assessment of the insulating properties of mixtures with ester content in mineral oil from 0 to 100% is given. The main characteristics of mixtures are described, such as density, kinematic viscosity, flash point, dielectric loss tangent, relative permittivity, breakdown voltage, moisture content and oxidation stability. It is shown that with an increase in the proportion of ester, some parameters of the obtained insulating liquid improve (flash point, relative permittivity, breakdown voltage, oxidation stability, corrosive sulfur), while other parameters (density, kinematic viscosity, dielectric dissipation factor) change to invalid values. Unlike a mixture of pure unused mineral oil with ester, the addition of unused synthetic ester to used high aromatic mineral oil (taken from a transformer in operation) results in an abnormal increase in the dielectric dissipation factor.

1 September 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MLMarina N. Lyutikova
Marina N. Lyutikova
SKSergey M. Korobeynikov
Sergey M. Korobeynikov
ARAlexander V. Ridel
Alexander V. Ridel
DVDenis V. Vagin
Denis V. Vagin
AKAlexander A. Konovalov
Alexander A. Konovalov
In high voltage oil-filled equipment, mineral insulating oil has two main functions - to remove heat from heated parts and to insulate conductors. Regardless of the temperature, transformer oil must always provide reliable insulation of high-voltage equipment elements. The primary indicator characterizing the electrical insulating properties of mineral oil is its electrical strength. This work presents the results of the study, which reflect the change in the value of the breakdown voltage of the oil during its cooling from + 60 °C to -20 °C. Modeling shows that when the cell is cooled, together with its contents, conditions are realized on the electrodes for the predominant formation of water in the form of drops or ice particles. Such an experiment and simulation shows the processes occurring in the insulation of a power transformer during its forced commissioning and decommissioning at negative temperatures. Experimental data on the nature of changes in the breakdown voltage of a liquid dielectric depending on the cooling method and the degree of oil oxidation are presented. Ice crystals form in the oil as it cools, the shape of which is different. It was found that in the process of oil cooling in the interelectrode gap, an “ice cloud” or “ice bridge” is formed. During thawing, emulsion water is formed from ice inclusions, which are concentrated on the electrodes of the measuring cell. It was experimentally determined that under high voltage action in small gaps of the measuring cell, water droplets are drawn out, forming a "water bridge" between the electrodes.

16 October 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
SKSergey M. Korobeynikov
Sergey M. Korobeynikov
SKSergey Krivosheev
Sergey Krivosheev
SMSergey Magazinov
Sergey Magazinov
VLValentin A. Loman
Valentin A. Loman
NYNikolay Ya
Nikolay Ya
High-frequency overvoltages are most dangerous for the insulation of transformer coils. It is because high-frequency pulse voltage creates an uneven distribution of voltage across the windings. The coil's first turns receive a disproportionately high voltage drop, leading to the inter-turn circuit. The paper analyzes the types of lightning pulses and proposes a new suppression method based on the anomalous skin effect in a multilayer material and the design in the form of a coil. The developed device is simulated, and the results of overvoltage monitoring at the substation with the installed high-frequency overvoltage suppression device are analyzed.

19 November 2002
Verified
Conference Paper
Closed access
EYE.V. Yanshin
E.V. Yanshin
SKS.M. Korobeynikov
S.M. Korobeynikov
IOI.T. Ovchinnikov
I.T. Ovchinnikov
SSS.G. Sarin
S.G. Sarin
KYK.V. Yanshin
K.V. Yanshin
AKA.V. Klepikov
A.V. Klepikov

1 January 2021 in Interfacial Phenomena and Heat Transfer
Verified
Journal Article
Closed access
PDF file
SKSergey M. Korobeynikov
Sergey M. Korobeynikov
ARA. V. Ridel
A. V. Ridel
DVD. V. Vagin
D. V. Vagin
Bubble dissolution in several liquids is recorded optically. The bubble dissolution rate in a liquid depends on the gas solubility and its diffusion speed in the liquid. Comparing the calculated dissolution curves (using the fitted diffusion coefficient) with the measured curves is a method used to determine the diffusion coefficient. The method was tested on known experimental data on methane diffusion in water, in which the calculated and tabular data differed by about 10%. The calculated dissolution curves noticeably differed when the diffusion coefficient was varied within ± 5%. The diffusion coefficients of the leading diagnostic gases (hydrogen, methane, ethane, and ethylene) in dielectric fluids in which the solubility coefficients are known (transformer, rapeseed, castor oil, and silicon fluid) were determined. Some anomalies in the observed results may have resulted from the gas purity in the bubbles during bubble formation and the liquid's residual dissolved air concentrations. Differences with the primary data resulted from more careful preparation of clean oils and gases, leading to higher diffusion coefficient values. The proposed measurement and simulation procedure was verified and validated by the experiments. The obtained data and determination methods are essential for applications of gas-liquid systems and can help better understand their behavior.

8 May 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MLMarina N. Lyutikova
Marina N. Lyutikova
SKSergey M. Korobeynikov
Sergey M. Korobeynikov
ARAlexander V. Ridel
Alexander V. Ridel
The leading position among liquid dielectrics used in high-voltage equipment is occupied by transformer oil. Over 130 years of using insulating oil, a lot of valuable information has been obtained, in particular: about the condition of the oil during its operation; about methods for restoring its characteristics; known methods of protection against active oxidation; methods for monitoring oil parameters and assessing the condition of the insulation system of oil-filled equipment have been developed. Despite the fact that mineral oils cope quite well with their functions - insulation and heat removal, there are a number of properties that do not meet the requirements of modern energy. Thus, in terms of fire resistance, chemical stability and biodegradability, transformer oils are significantly inferior to ester dielectric fluids, which are quite widely used by foreign energy companies. In addition, transformer oils, during their prolonged use in electrical equipment, are capable of forming sediments of various consistencies. For efficient and reliable operation of the insulation system, such precipitation is extremely undesirable. This article proposes a method for optimizing the properties of transformer oil (aromatic, paraffin) to stabilize the sedimentation process by mixing the oil with a synthetic ester in a certain ratio.