Valentin A. Loman

Valentin A. Loman

Auto-generated profile, based on publicly available information

Valentin A. Loman

Novosibirsk State Technical University,Labor Safety Department,Novosibirsk,Russia

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
SKSergey M. Korobeynikov
Sergey M. Korobeynikov
SKSergey Krivosheev
Sergey Krivosheev
SMSergey Magazinov
Sergey Magazinov
VLValentin A. Loman
Valentin A. Loman
NYNikolay Ya
Nikolay Ya
High-frequency overvoltages are most dangerous for the insulation of transformer coils. It is because high-frequency pulse voltage creates an uneven distribution of voltage across the windings. The coil's first turns receive a disproportionately high voltage drop, leading to the inter-turn circuit. The paper analyzes the types of lightning pulses and proposes a new suppression method based on the anomalous skin effect in a multilayer material and the design in the form of a coil. The developed device is simulated, and the results of overvoltage monitoring at the substation with the installed high-frequency overvoltage suppression device are analyzed.

27 June 2025
Verified
Conference Paper
Closed access
SKSergey Korobeynikov
Sergey Korobeynikov
VLValentin Loman
Valentin Loman
ARAlexander Ridel
Alexander Ridel
VSVladimir Shevchenko
Vladimir Shevchenko
VLViktor Loskutov
Viktor Loskutov
This paper addresses the issue of protecting power facilities from high-frequency overvoltage pulses of lightning and switching origin. An experimental comparison of the effects of a Frequency-Dependent Device and a line trap mockup on MHz-range overvoltage pulses is presented. In contrast to previous studies, this work utilizes full-scale FDD samples and an LT mockup replicating the FDD design but without ferromagnetic and insulating layers. An improved measurement methodology was developed and tested, enabling the generation of steep-front pulses (simulating lightning/switching overvoltages). The results demonstrate that the FDD reduces the pulse front steepness 25 % more effectively than the LT mockup, owing to its ferromagnetic layer, which increases active resistance at high frequencies ($450-500 \Omega$ at $1.2-1.8 \text{MHz}$). These findings highlight the potential of FDDs for protecting power facilities from highfrequency overvoltages and provide a foundation for further research in the $10 \text{kHz}-5 \text{MHz}$ range. The work also revealed several nuances that could improve future high-frequency measurements.