Min Chen

Min Chen

Auto-generated profile, based on publicly available information

Min Chen

Image Analysis and Communications Laboratory, Dept. of ECE, Johns Hopkins University

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2013 in NeuroImage
Verified
Journal Article
Closed access
MCMin Chen
Min Chen
ACAaron Carass
Aaron Carass
JOJiwon Oh
Jiwon Oh
GNGovind Nair
Govind Nair
DPDzung L. Pham
Dzung L. Pham
JPJerry L Prince
Jerry L Prince

5 March 2014 in Journal of Neuroimaging
Verified
Journal Article
Closed access
PDF file
JOJiwon Oh
Jiwon Oh
MSMichaela Seigo
Michaela Seigo
SSShiv Saidha
Shiv Saidha
ESElias Sotirchos
Elias Sotirchos
KZKathy Zackowski
Kathy Zackowski
DRDaniel Reich
Daniel Reich

11 June 2014 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
MCMin Chen
Min Chen
ALAndrew Lang
Andrew Lang
HYHoward S. Ying
Howard S. Ying
PCPeter A Calabresi
Peter A Calabresi
JPJerry L. Prince
Jerry L. Prince
ACAaron Carass
Aaron Carass
Optical coherence tomography (OCT) of the macula has become increasingly important in the investigation of retinal pathology. However, deformable image registration, which is used for aligning subjects for pairwise comparisons, population averaging, and atlas label transfer, has not been well–developed and demonstrated on OCT images. In this paper, we present a deformable image registration approach designed specifically for macular OCT images. The approach begins with an initial translation to align the fovea of each subject, followed by a linear rescaling to align the top and bottom retinal boundaries. Finally, the layers within the retina are aligned by a deformable registration using one-dimensional radial basis functions. The algorithm was validated using manual delineations of retinal layers in OCT images from a cohort consisting of healthy controls and patients diagnosed with multiple sclerosis (MS). We show that the algorithm overcomes the shortcomings of existing generic registration methods, which cannot be readily applied to OCT images. A successful deformable image registration algorithm for macular OCT opens up a variety of population based analysis techniques that are regularly used in other imaging modalities, such as spatial normalization, statistical atlas creation, and voxel based morphometry. Examples of these applications are provided to demonstrate the potential benefits such techniques can have on our understanding of retinal disease. In particular, included is a pilot study of localized volumetric changes between healthy controls and MS patients using the proposed registration algorithm.

20 March 2015 in Proceedings of SPIE
Verified
Conference Paper
Closed access
PDF file
MCMin Chen
Min Chen
AJAmog Jog
Amog Jog
ACAaron Carass
Aaron Carass
JPJerry L. Prince
Jerry L. Prince
This paper presents a multi-channel approach for performing registration between magnetic resonance (MR) images with different modalities. In general, a multi-channel registration cannot be used when the moving and target images do not have analogous modalities. In this work, we address this limitation by using a random forest regression technique to synthesize the missing modalities from the available ones. This allows a single channel registration between two different modalities to be converted into a multi-channel registration with two mono- modal channels. To validate our approach, two openly available registration algorithms and five cost functions were used to compare the label transfer accuracy of the registration with (and without) our multi-channel synthesis approach. Our results show that the proposed method produced statistically significant improvements in registration accuracy (at an α level of 0.001) for both algorithms and all cost functions when compared to a standard multi-modal registration using the same algorithms with mutual information.

1 April 2013
Verified
Conference Paper
Closed access
MCMin Chen
Min Chen
ALAndrew Lang
Andrew Lang
ESElias Sotirchos
Elias Sotirchos
HYHoward S. Ying
Howard S. Ying
PCPeter A Calabresi
Peter A Calabresi
ACAaron Carass
Aaron Carass
Optical coherence tomography (OCT) of the macular cube has become an increasingly important tool for investigating and managing retinal pathology. One important new area of investigation is the analysis of anatomic variably across a population. Such an analysis on the retina requires the construction of a normalized space, which is generally created through deformable registration of each subject into a common template. Unfortunately, state-of-the-art 3D registration tools fail to adequately spatially normalize retinal OCT images. This work proposes a new deformable registration algorithm for OCT images using the similarity between pairs of A-mode scans. First, a retinal OCT specific affine step is presented, which uses automated landmarks to perform global translations and individual rescaling of all the subject's Amode scans. Then, a deformable registration using regularized one-dimensional radial basis functions is applied to further align the retinal layers. Results on 15 subjects show the improved accuracy of this approach in comparison to state of the art methods with respect to registration for labeling. Additional results show the ability to generate stereotaxic spaces for retinal OCT.

1 March 2011
Verified
Conference Paper
Closed access
MCMin Chen
Min Chen
ACAaron Carass
Aaron Carass
JCJennifer Cuzzocreo
Jennifer Cuzzocreo
PBPierre-Louis Bazin
Pierre-Louis Bazin
DRDaniel Reich
Daniel Reich
JPJerry L Prince
Jerry L Prince
Magnetic resonance images of the spinal cord play an important role in studying neurological diseases, particularly multiple sclerosis, where spinal cord atrophy can provide a measure of disease progression and disability. Current practices involve segmenting the spinal cord manually, which can be an inconsistent and time-consuming process. We present an automatic segmentation method for the spinal cord using a novel combination of deformable atlas based registration and topology preserving classification to address the challenges inherent to MR images of the spinal cord. Using real MR data, our method is shown to be highly accurate when compared to segmentations by manual raters. In addition, our results always maintain the correct topology of the spinal cord, therefore providing segmentations more consistent with the known anatomy.