Lena Emanuelsson

Lena Emanuelsson

Auto-generated profile, based on publicly available information

Lena Emanuelsson

Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Acta Biomaterialia
Verified
Journal Article
Open access
DKDimitrios Karazisis
Dimitrios Karazisis
LRLars Rsasmusson
Lars Rsasmusson
SPSarunas Petronis
Sarunas Petronis
APAnders Palmquist
Anders Palmquist
FSFurqan A. Shah
Furqan A. Shah
Peter ThomsenPeter Thomsen
Peter Thomsen
The initial cellular and molecular activities at the bone interface of implants with controlled nanoscale topography and microscale roughness have previously been reported. However, the effects of such surface modifications on the development of osseointegration have not yet been determined. This study investigated the molecular events and the histological and biomechanical development of the bone interface in implants with nanoscale topography, microscale roughness or a combination of both. Polished and machined titanium implants with and without controlled nanopatterning (75 nm protrusions) were produced using colloidal lithography and coated with a thin titanium layer to unify the chemistry. The implants were inserted in rat tibiae and subjected to removal torque (RTQ) measurements, molecular analyses and histological analyses after 6, 21 and 28 days. The results showed that nanotopography superimposed on microrough, machined, surfaces promoted an early increase in RTQ and hence produced greater implant stability at 6 and 21 days. Two-way MANOVA revealed that the increased RTQ was influenced by microscale roughness and the combination of nanoscale and microscale topographies. Furthermore, increased bone-implant contact (BIC) was observed with the combined nanopatterned machined surface, although MANOVA results implied that the increased BIC was mainly dependent on microscale roughness. At the molecular level, the nanotopography, per se, and in synergy with microscale roughness, downregulated the expression of the proinflammatory cytokine tumor necrosis factor alpha (TNF-α). In conclusion, controlled nanotopography superimposed on microrough machined implants promoted implant stability during osseointegration. Nanoscale-driven mechanisms may involve attenuation of the inflammatory response at the titanium implant site. STATEMENT OF SIGNIFICANCE: The role of combined implant microscale and nanotopography features for osseointegration is incompletely understood. Using colloidal lithography technique, we created an ordered nanotopography pattern superimposed on screwshaped implants with microscale topography. The midterm and late molecular, bone-implant contact and removal torque responses were analysed in vivo. Nanotopography superimposed on microrough, machined, surfaces promoted the implant stability, influenced by microscale topography and the combination of nanoscale and microscale topographies. Increased bone-implant contact was mainly dependent on microscale roughness whereas the nanotopography, per se, and in synergy with microscale roughness, attenuated the proinflammatory tumor necrosis factor alpha (TNF-α) expression. It is concluded that microscale and nanopatterns provide individual as well as synergistic effects on molecular, morphological and biomechanical implant-tissue processes in vivo.

1 August 2023 in Bioactive Materials
Verified
Journal Article
Open access
HAHeithem Ben Amara
Heithem Ben Amara
Diana Martinez GuerreroDiana Martinez Guerrero
Diana Martinez Guerrero
Furqan ShahFurqan Shah
Furqan Shah
ALAnna Johansson Loo
Anna Johansson Loo
LELena Emanuelsson
Lena Emanuelsson
Peter ThomsenPeter Thomsen
Peter Thomsen
Implants made of magnesium (Mg) are increasingly employed in patients to achieve osteosynthesis while degrading in situ. Since Mg implants and Mg2+ have been suggested to possess anti-inflammatory properties, the clinically observed soft tissue inflammation around Mg implants is enigmatic. Here, using a rat soft tissue model and a 1-28 d observation period, we determined the temporo-spatial cell distribution and behavior in relation to sequential changes of pure Mg implant surface properties and Mg2+ release. Compared to nondegradable titanium (Ti) implants, Mg degradation exacerbated initial inflammation. Release of Mg degradation products at the tissue-implant interface, culminating at 3 d, actively initiated chemotaxis and upregulated mRNA and protein immunomodulatory markers, particularly inducible nitric oxide synthase and toll-like receptor-4 up to 6 d, yet without a cytotoxic effect. Increased vascularization was demonstrated morphologically, preceded by high expression of vascular endothelial growth factor. The transition to appropriate tissue repair coincided with implant surface enrichment of Ca and P and reduced peri-implant Mg2+ concentration. Mg implants revealed a thinner fibrous encapsulation compared with Ti. The detailed understanding of the relationship between Mg material properties and the spatial and time-resolved cellular processes provides a basis for the interpretation of clinical observations and future tailoring of Mg implants.

30 August 2024 in Biomaterials
Verified
Journal Article
Open access
HAHeithem Ben Amara
Heithem Ben Amara
Diana Martinez GuerreroDiana Martinez Guerrero
Diana Martinez Guerrero
KIKamila Iskhakova
Kamila Iskhakova
LELena Emanuelsson
Lena Emanuelsson
BNBirgitta Norlindh
Birgitta Norlindh
Peter ThomsenPeter Thomsen
Peter Thomsen
Orthopedic implants made of biodegradable magnesium (Mg) provide an alternative to nondegradable implants for fracture repair. Widely reported to be pro-osteogenic, Mg implants are also believed to be anti-inflammatory and anti-osteoclastic, but this is difficult to reconcile with the early clinical inflammation observed around these implants. Here, by surveying implant healing in a rat bone model, we determined the cellular responses and structural assembly of bone correlated with the surface changes of Mg implants inherent in degradation. We show that, compared to titanium, both high-purity (99.998 %) and clinical-grade, rare earth-alloyed (MgYREZr) Mg implants create an initial, transient proinflammatory environment that facilitates inducible nitric oxide synthase-mediated macrophage polarization, osteoclastogenesis, and neoangiogenesis programs. While this immunomodulation subsequently reinforces reparative osteogenesis at the surface of both Mg implants, the faster degradation of high-purity Mg implants, but not MgYREZr implants, elicits a compositional alteration in the interfacial bone and a previously unknown proadipogenic response with persistent low-grade inflammation in the surrounding bone marrow. Beyond the need for rigorous tailoring of Mg implants, these data highlight the need to closely monitor osseointegration not only at the immediate implant surface but also in the peri-implant bone and adjacent bone marrow.