Roberto Matía

Roberto Matía

Auto-generated profile, based on publicly available information

Roberto Matía

Arrhythmia Unit, Cardiology Department, Ramon y Cajal Hospital, Madrid, Spain

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2013 in European Heart Journal
Verified
Journal Article
Open access
PDF file
LMLluís Mont
Lluís Mont
FBFelipe Bisbal
Felipe Bisbal
AHAntonio Hernández-Madrid
Antonio Hernández-Madrid
NPNicasio Pérez-Castellano
Nicasio Pérez-Castellano
XVXavier Viñolas
Xavier Viñolas
JBJosep Brugada
Josep Brugada
Catheter ablation (CA) is a highly effective therapy for the treatment of paroxysmal atrial fibrillation (AF) when compared with antiarrhythmic drug therapy (ADT). No randomized studies have compared the two strategies in persistent AF. The present randomized trial aimed to compare the effectiveness of CA vs. ADT in treating persistent AF. Patients with persistent AF were randomly assigned to CA or ADT (excluding patients with long-standing persistent AF). Primary endpoint at 12-month follow-up was defined as any episode of AF or atrial flutter lasting >24 h that occurred after a 3-month blanking period. Secondary endpoints were any atrial tachyarrhythmia lasting >30 s, hospitalization, and electrical cardioversion. In total, 146 patients were included (aged 55 ± 9 years, 77% male). The ADT group received class Ic (43.8%) or class III drugs (56.3%). In an intention-to-treat analysis, 69 of 98 patients (70.4%) in the CA group and 21 of 48 patients (43.7%) in the ADT group were free of the primary endpoint (P = 0.002), implying an absolute risk difference of 26.6% (95% CI 10.0–43.3) in favour of CA. The proportion of patients free of any recurrence (>30 s) was higher in the CA group than in the ADT group (60.2 vs. 29.2%; P < 0.001) and cardioversion was less frequent (34.7 vs. 50%, respectively; P = 0.018). Catheter ablation is superior to medical therapy for the maintenance of sinus rhythm in patients with persistent AF at 12-month follow-up. NCT00863213 (http://clinicaltrials.gov/ct2/show/NCT00863213).

1 April 2017 in Heart Rhythm
Verified
Journal Article
Open access
AHAntonio Hernández‐Madrid
Antonio Hernández‐Madrid
DFDomenico Facchin
Domenico Facchin
RKRuth Nicholson Klepfer
Ruth Nicholson Klepfer
SGSubham Ghosh
Subham Ghosh
RMRoberto Matía
Roberto Matía
ALAlessandro Locatelli
Alessandro Locatelli
A high percentage of biventricular (BiV) or left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) devices has been associated with superior clinical outcomes. However, the percent ventricular (%V) pacing reported by CRT devices simply indicates the number of paces the device has delivered and not the proportion of pacing that has captured the LV effectively. The purpose of this study was to determine whether a beat-by-beat evaluation of effective pacing would provide a more accurate evaluation of CRT delivery. An automatic electrogram (EGM)-based algorithm that classifies each LV pace as effective or ineffective based on detection of QS/QS-r morphology on the unipolar LV EGM during pacing was developed and validated. LV EGMs that were recorded by 24-hour Holter from 57 CRT patients were postprocessed. The percent effective CRT (%e-CRT) pacing was calculated by dividing the time spent in e-CRT pacing by the total time of the recording. In this CRT cohort, the average %V pacing (94.8% ± 8%) significantly overestimated the %e-CRT pacing (87.5% ± 23%; P <.001). A significant minority of subjects (18%) had a discrepancy of at least 3 percentage points between %V pacing and %e-CRT pacing (mean 39% ± 41%). Current device pacing diagnostics overestimate the amount of CRT pacing actually delivered. The new algorithm quantifies ineffective CRT pacing, which enables clinicians to identify patients with this issue and to address the reasons behind suboptimal CRT delivery.

1 June 2015 in The American Journal of Cardiology
Verified
Journal Article
Closed access
IAIgnasi Anguera
Ignasi Anguera
PDPaolo Dallaglio
Paolo Dallaglio
RMRosa Macías
Rosa Macías
JJJavier Jiménez-Candil
Javier Jiménez-Candil
RPRafael Peinado
Rafael Peinado
XSXavier Sabaté
Xavier Sabaté

12 February 2016 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
EFEduardo Franco
Eduardo Franco
DMDaniel Rodriguez Muñoz
Daniel Rodriguez Muñoz
RMRoberto Matía
Roberto Matía
AHAntonio Hernandez‐Madrid
Antonio Hernandez‐Madrid
ARAlejandra Carbonell San Román
Alejandra Carbonell San Román
JMJavier Moreno
Javier Moreno

1 November 2013 in EP Europace
Verified
Journal Article
Open access
PDF file
RFRoberto MatÍA FrancÉS
Roberto MatÍA FrancÉS
AMAntonio HernÁNdez Madrid
Antonio HernÁNdez Madrid
ADAntonia Delgado
Antonia Delgado
LCLaura Carrizo
Laura Carrizo
CPCarlos Pindado
Carlos Pindado
JGJosÉ L. Zamorano GÓMez
JosÉ L. Zamorano GÓMez
Catheter–tissue contact is critical for effective lesion creation. The objective of this study was to determine in an experimental swine model the pathological effects of cavo-tricuspid isthmus ablation using two systems that provide reliable measures of the pressure at the catheter tip during radiofrequency ablation procedures. We performed the procedure in eight pigs in our experimental electrophysiology laboratory after right femoral vein dissection and insertion of a 12 Fr. introducer during general anaesthesia and endotracheal intubation. The target contact force during the applications was 30 grs. in two pigs each. The power was set at 40 W and maximum target temperature at 45°C. We performed a radiofrequency line dragging from the tricuspid valve to the inferior vena cava in the eight pigs. Euthanasia of the animals was carried out a week after the procedure and a pathological examination of the lesions was performed. In the endocardial macroscopic analysis the extent of lesions, presence of thrombus, transmurality, and endothelial rupture was assessed. External surface was examined searching for transmural lesions. The mean contact force applied was 18.7 ± 8.4 grs. and the mean depth of the lesions was 3.6 ± 2 mm. Lesions were never transmural with average forces <10 grs., and the mean depth was very low (0.75 mm). To achieve transmural lesions contact forces of at least 20 grs. were required. We found a positive correlation (r = 0.85, P < 0.05) between the average force during the applications and depth of the lesions. When ablating the cavo-tricuspid isthmus in a swine model, contact forces of at least 20 grs. are required to achieve transmural lesions. Catheter–tissue contact is critical for effective lesion creation. This information is important for improving ablation efficacy.

27 October 2015 in EP Europace
Verified
Journal Article
Open access
PDF file
PDPaolo D. Dallaglio
Paolo D. Dallaglio
IAIgnasi Anguera
Ignasi Anguera
JJJavier Jiménez-Candil
Javier Jiménez-Candil
RPRafael Peinado
Rafael Peinado
JSJavier García Seara
Javier García Seara
XSXavier Sabaté
Xavier Sabaté
Aims The aim of this study was to determine the acute and long-term outcome of radiofrequency catheter ablation (RFCA) for cavotricuspid isthmus-dependent atrial flutter (CTI-AFL) in adults with and without previous cardiac surgery (PCS), and predictors of these outcomes. Structural alterations of the anatomical substrate of the CTI-AFL are observed in post-operative patients, and these may have an impact on the acute success of the ablation and in the long-term. Methods and results Clinical records of consecutive adults undergoing RFCA of CTI-AFL were analysed. Two main groups were considered: No PCS and PCS patients, who were further subdivided into acquired heart disease (AHD: ischaemic heart disease and valvular/mixed heart disease) and congenital heart disease [CHD: ostium secundum atrial septal defect (OS-ASD) and complex CHD]. Multivariate analysis identified clinical and procedural factors that predicted acute and long-term outcomes. A total of 666 patients (73% men, age 65 ± 12 years) were included: 307 of them with PCS. Ablation was successful in 647 patients (97%), 96% in the PCS group and 98% in the No PCS group (P = 0.13). Regression analysis showed that surgically corrected complex CHD was related to failure of the procedure [odds ratio 5.6; 95% confidence interval (CI) 1.6–18, P = 0.008]. After a follow-up of 45 ± 15 months, recurrences were observed in 90 patients (14%), more frequently in the PCS group: absolute risk of recurrence 18 vs. 10.5%, relative risk 1.71, 95% CI: 1.2–2.5, P = 0.006. Multivariate analysis indicated that the types of PCS [OS-ASD vs. No PCS: hazard ratio (HR) 2.57; 95% CI: 1.1–6.2, P = 0.03 and complex CHD vs. No PCS: HR 2.75; 95% CI: 1.41–5.48, P = 0.004], female gender (HR 1.55; 95% CI: 1.04–2.4, P = 0.048), and severe LV dysfunction (HR 1.36; 95% CI: 1.06–1.67, P = 0.04) were independent predictors of long-term recurrence. Conclusion Radiofrequency catheter ablation of CTI-AFL after surgical correction of AHD and CHD is associated with high acute success rates. The severity of the structural alterations of the underlying heart disease and consequently the type of surgical correction correlates with higher risk for recurrence.