Domenico Facchin

Domenico Facchin

Auto-generated profile, based on publicly available information

Domenico Facchin

Azienda Sanitaria Universitaria Friuli Centrale – Ospedale Santa Maria della Misericordia , Udine; , Trieste

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in Heart Rhythm
Verified
Journal Article
Open access
AHAntonio Hernández‐Madrid
Antonio Hernández‐Madrid
DFDomenico Facchin
Domenico Facchin
RKRuth Nicholson Klepfer
Ruth Nicholson Klepfer
SGSubham Ghosh
Subham Ghosh
RMRoberto Matía
Roberto Matía
ALAlessandro Locatelli
Alessandro Locatelli
A high percentage of biventricular (BiV) or left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) devices has been associated with superior clinical outcomes. However, the percent ventricular (%V) pacing reported by CRT devices simply indicates the number of paces the device has delivered and not the proportion of pacing that has captured the LV effectively. The purpose of this study was to determine whether a beat-by-beat evaluation of effective pacing would provide a more accurate evaluation of CRT delivery. An automatic electrogram (EGM)-based algorithm that classifies each LV pace as effective or ineffective based on detection of QS/QS-r morphology on the unipolar LV EGM during pacing was developed and validated. LV EGMs that were recorded by 24-hour Holter from 57 CRT patients were postprocessed. The percent effective CRT (%e-CRT) pacing was calculated by dividing the time spent in e-CRT pacing by the total time of the recording. In this CRT cohort, the average %V pacing (94.8% ± 8%) significantly overestimated the %e-CRT pacing (87.5% ± 23%; P <.001). A significant minority of subjects (18%) had a discrepancy of at least 3 percentage points between %V pacing and %e-CRT pacing (mean 39% ± 41%). Current device pacing diagnostics overestimate the amount of CRT pacing actually delivered. The new algorithm quantifies ineffective CRT pacing, which enables clinicians to identify patients with this issue and to address the reasons behind suboptimal CRT delivery.

13 June 2017 in Journal of Evaluation in Clinical Practice
Verified
Journal Article
Closed access
PDF file
RCRosanna Irene Comoretto
Rosanna Irene Comoretto
DFDomenico Facchin
Domenico Facchin
MGMarco Ghidina
Marco Ghidina
APAlessandro Proclemer
Alessandro Proclemer
Dario GregoriDario Gregori
Dario Gregori

11 June 2022 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
VRValentina De Regibus
Valentina De Regibus
MBMauro Biffi
Mauro Biffi
TITommaso Infusino
Tommaso Infusino
SSSimone Savastano
Simone Savastano
MLMaurizio Landolina
Maurizio Landolina
MZMatteo Ziacchi
Matteo Ziacchi

18 May 2023 in European Heart Journal Supplements
Verified
Journal Article
Open access
PDF file
VFV Favaretto
V Favaretto
FFF Fumarola
F Fumarola
CTC Tioni
C Tioni
DFD Facchin
D Facchin
MDM Driussi
M Driussi
GSGianfranco Sinagra
Gianfranco Sinagra
Outpatient monitoring of patients with chronic heart failure (HF) may result in HF exacerbation and subsequent hospitalizations that may be avoided with an early recognition. The HeartLogic (HL) algorithm automatically calculates a daily HF index based on values including heart sounds, markers of ventilation, thoracic impedance, activity and heart rate and recognize an active alert state relative to a configurable threshold. We included 35 patients with HF in optimized medical therapy; the investigational chronic ambulatory data collection was performed via implanted Boston pace–maker, defibrillator or cardiac resynchronization therapy and we analyzed these data since February 2021, ongoing. We established a cut off of HL index of 16 due to the confirmatory trial and we contacted the patients 2 weeks after the threshold exceeding to evaluate their clinical state. Preliminary data (until December 2021) showed us 24 alarms in total, of whom 7 were truly heart failure related alarms. These are independent from the values of the HL index reached and the best parameter resulted to be the chest impedance. Measurement of third heart sound was another sensitive but not very specific parameter. The main confounding factor was given by infections, especially related to Covid–19. The therapeutic strategy was predominantly increasing the doses of diuretics. There were no heart failure events in patients without the warning HL index. The preliminary data showed us how high is the negative predictor factor of the HL index based on our center parameters. We aim to analyze further data to be more accurate and to find the best way to detect heart failure.