Satya Sundar Patra

Satya Sundar Patra

Auto-generated profile, based on publicly available information

Satya Sundar Patra

Lyles School of Civil and Construction Engineering

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2023 in Environmental Science & Technology
Verified
Journal Article
Open access
JJJinglin Jiang
Jinglin Jiang
XDXiaosu Ding
Xiaosu Ding
SPSatya S. Patra
Satya S. Patra
JCJordan N. Cross
Jordan N. Cross
CHChunxu Huang
Chunxu Huang
NJNusrat Jung
Nusrat Jung
Cyclic volatile methyl siloxanes (cVMS) are ubiquitous in hair care products (HCPs). cVMS emissions from HCPs are of concern, given the potential adverse impact of siloxanes on the environment and human health. To characterize cVMS emissions and exposures during the use of HCPs, realistic hair care experiments were conducted in a residential building. Siloxane-based HCPs were tested using common hair styling techniques, including straightening, curling, waving, and oiling. VOC concentrations were measured via proton-transfer-reaction time-of-flight mass spectrometry. HCP use drove rapid changes in the chemical composition of the indoor atmosphere. cVMS dominated VOC emissions from HCP use, and decamethylcyclopentasiloxane (D5) contributed the most to cVMS emissions. cVMS emission factors (EFs) during hair care routines ranged from 110-1500 mg/person and were influenced by HCP type, styling tools, operation temperatures, and hair length. The high temperature of styling tools and the high surface area of hair enhanced VOC emissions. Increasing the hair straightener temperature from room temperature to 210 °C increased cVMS EFs by 50-310%. Elevated indoor cVMS concentrations can result in substantial indoor-to-outdoor transport of cVMS via ventilation (0.4-6 tons D5/year in the U.S.); thus, hair care routines may augment the abundance of cVMS in the outdoor atmosphere.

1 February 2024 in PNAS Nexus
Verified
Journal Article
Open access
PDF file
SPSatya S Patra
Satya S Patra
JJJinglin Jiang
Jinglin Jiang
XDXiaosu Ding
Xiaosu Ding
CHChunxu Huang
Chunxu Huang
EREmily K Reidy
Emily K Reidy
BBBrandon Boor
Brandon Boor
Nanocluster aerosol (NCA: particles in the size range of 1–3 nm) are a critically important, yet understudied, class of atmospheric aerosol particles. NCA efficiently deposit in the human respiratory system and can translocate to vital organs. Due to their high surface area-to-mass ratios, NCA are associated with a heightened propensity for bioactivity and toxicity. Despite the human health relevance of NCA, little is known regarding the prevalence of NCA in indoor environments where people spend the majority of their time. In this study, we quantify the formation and transformation of indoor atmospheric NCA down to 1 nm via high-resolution online nanoparticle measurements during propane gas cooking in a residential building. We observed a substantial pool of sub-1.5 nm NCA in the indoor atmosphere during cooking periods, with aerosol number concentrations often dominated by the newly formed NCA. Indoor atmospheric NCA emission factors can reach up to ∼1016 NCA/kg-fuel during propane gas cooking and can exceed those for vehicles with gasoline and diesel engines. Such high emissions of combustion-derived indoor NCA can result in substantial NCA respiratory exposures and dose rates for children and adults, significantly exceeding that for outdoor traffic-associated NCA. Combustion-derived indoor NCA undergo unique size-dependent physical transformations, strongly influenced by particle coagulation and condensation of low-volatility cooking vapors. We show that indoor atmospheric NCA need to be measured directly and cannot be predicted using conventional indoor air pollution markers such as PM2.5 mass concentrations and NOx (NO + NO2) mixing ratios.

12 May 2020 in Globalization and Health
Verified
Journal Article
Open access
PDF file
SGSachin S. Gunthe
Sachin S. Gunthe
SPSatya S. Patra
Satya S. Patra
The recent pandemic caused by the 2019 outbreak of novel coronavirus (2019-nCoV or COVID-19) has affected more than 3.0 million people resulting ~ 212,000 deaths across 215 countries/territories as on 28th April 2020. The importation of the cases owing to enormous international travels from the affected countries is the foremost reason for local cycle of transmission. For a country like India, the second most populous country in the world with ~ 1.35 billion population, the management and control of 2019-nCoV domestic spread heavily relied on effective screening and strict quarantine of passengers arriving at various international airports in India from affected countries. Here, by extracting the data from FLIRT, an online airline database for more than 800 airlines, and scanning more than 180,000 flights and 39.9 million corresponding passenger seats during 4th – 25th March, we show that India experienced the highest risk index of importing the passengers from middle eastern airports. Contrary to perception, travelers from China imposed lowest risk of importing the infected cases in India. This is clearly evident form the fact that while the number of infected cases were on the peak in China India was one of the least affected countries. The number of cases in India started exhibiting a sharp increase in the infected cases only after the European countries and USA recorded large number of infected cases. We further argue that while the number of cases in middle eastern countries may still be very low, the airports in middle eastern countries, particularly Dubai, being one of the largest transit hubs for international passengers, including arriving in India, might have posed a higher risk of getting infected with 2019-nCoV. We suggest that any future travel related disease infection screening at the airports should critically assess the passengers from major transit hubs in addition to affected country of origin.

1 January 2019
Verified
Conference Paper
Closed access
SPSatya Sundar Patra
Satya Sundar Patra
BMBharathiraja Muthurajan
Bharathiraja Muthurajan
BCBhargava Rama Chilukuri
Bhargava Rama Chilukuri
LDLelitha Devi
Lelitha Devi
Recent digitalization has led to a significant increase in Data usage and WiFi penetration rates across the globe. WiFi Media Access Control (MAC) data, allows for unannounced and non-participatory tracking of electronic devices. This feature has attracted several transport researchers to use it in the estimation of spatial traffic parameters such as travel time. However, the commercial sensors available for WiFi MAC scanning are not affordable to be installed widely in a city.This paper talks about the development of a portable, low-cost Wireless Media Access Control Scanner and its evaluation for traffic applications. Control and field tests were done to identify the performance of the developed sensor. The developed sensor was found to work comparable or even better in urban traffic scenario when tested against a commercial counterpart.

24 September 2024 in ACS ES&T Air
Verified
Journal Article
Open access
SPSatya S. Patra
Satya S. Patra
JLJianghui Liu
Jianghui Liu
JJJinglin Jiang
Jinglin Jiang
XDXiaosu Ding
Xiaosu Ding
CHChunxu Huang
Chunxu Huang
BBBrandon Boor
Brandon Boor

24 September 2021 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
SPSatya S. Patra
Satya S. Patra
JNJyotishree Nath
Jyotishree Nath
SPSubhasmita Panda
Subhasmita Panda
TDTrupti Das
Trupti Das
Boopathy RamasamyBoopathy Ramasamy
Boopathy Ramasamy
Respiratory droplets serve as a viable transmission mechanism for many viruses and other pathogens. Facemasks are commonly used to minimize the risk of this transmission. However, information on the size-resolved filtration efficiency of commonly available commercial facemasks is not readily available in the literature. To fill this gap, the current study performs aerosolized chamber experiments to evaluate the filtration efficiencies of commonly available commercial facemasks’ materials in a size range of 0.3–10 µm. Results rank the performance of filtration through commercial facemasks’ materials as follows (values in brackets indicate the average filtration efficiencies across 0.3–10 µm): 6-Layer N95 mask (0.918) > N95 mask – without valve (0.88) > KN95 mask (0.84) > N95 mask -with valve (0.834) > Heavy knitted cotton mask (0.808) > Surgical mask (0.778) > Cotton mask-2 layers (0.744) > Nylon fabric mask-2 layers (0.740) > T-shirt fabric mask-2 layers (0.708) > T-shirt fabric mask-1 layer (0.648). The size-resolved filtration efficiencies through the material across the evaluated commercial facemasks ranged from 38–83% in the size range of 0.3–0.5 µm, 55–88% in the size range of 0.5–1 µm, 69–93% in the size range of 1–2.5 µm, 76–96% in the size range of 2.5–5 µm, and 86–99% in the size range of 5–10 µm. Subsequently, the filtration efficiencies of materials post washing (with detergent in warm water and allowing to dry completely) were also evaluated. The average reduction in filtration efficiencies post washing are as follows: 6-Layer N95 mask: 3%, N95 mask – without valve: 2%, KN95 mask: 4%, N95 mask -with valve: 3%, Heavy knitted cotton mask: 4%, Surgical mask: 18%, Cotton mask-2 layers: 11%, Nylon fabric mask-2 layers: 6%, T-shirt fabric mask-2 layers: 6%, T-shirt fabric mask-1 layer: 8%. This decrease in the filtration efficiency was more pronounced for the sub-micron particles than the super-micron ones. Implications: Facemasks are commonly used to minimize the risk of pathogens through ambient air transmission. However, information on the size-resolved filtration efficiency of commonly available commercial facemasks materials is not readily available in the literature. To fill this gap, the current study performs aerosolized chamber experiments to evaluate the filtration efficiencies of commonly available commercial facemasks materials in a size range of 0.3–10 µm. The performance of the commercial facemasks materials as follows in the order of (values in brackets indicate the average filtration efficiencies across 0.3–10 µm): 6-Layer N95 mask (0.918) > N95 mask – without valve (0.88) > KN95 mask (0.84) > N95 mask -with valve (0.834) > Heavy knitted cotton mask (0.808) > Surgical mask (0.778) > Cotton mask-2 layers (0.744) > Nylon fabric mask-2 layers (0.740) > T-shirt fabric mask-2 layers (0.708) > T-shirt fabric mask-1 layer (0.648). The choice of facemask is greatly driven by the size of viable respiratory droplets that need to be eliminated. If droplets with particle size less than 0.5 µm are required to be filtered, N95 masks without the valve or more layers are preferred. If the primary objective is to filter particles between 0.5–1 µm, then N95 (both with or without valves) or KN95 masks are recommended. Surgical masks and heavy knitted cotton masks may also be used for this purpose, but with caution.