18 September 2019 in IEEE Transactions on Radiation and Plasma Medical Sciences
In this work, we present an efficient methodology for multigrid tomographic image reconstruction from non-truncated projection data. By partitioning the reconstruction domain and adapting the forward and backward operators, an image can be reconstructed accurately within multiple domains of varying discretisation or regularisation. We demonstrate the efficacy of the multigrid reconstruction principle using simulated data for quantitative assessment and experimental measurements from a μ-CT scanner for a clinically relevant use case scenario. A major advantage of using multiple reconstruction grids is the possibility to drastically reduce the number of unknowns in the inverse problem, and thereby the associated computational cost. This cost reduction helps to enlarge the class of available algorithms in applications with strict limitations on computation time or resources, and it enables full system resolution reconstruction of subregions that would otherwise be infeasible for the full field of view. The numerical experiments, along with a brief error analysis, show that the expected artefacts from coarse discretisation outside the region of interest become noticeable only for large differences in discretisation between subregions.
1 May 2020 in Radiation Physics and Chemistry
12 May 2021 in IEEE Transactions on Nuclear Science
Data collected from the X-ray fluorescence-computed tomography (XFCT) is frequently reconstructed with algorithms proposed for X-ray transmission tomography. As these algorithms do not model the self-absorption effect inherent to XFCT, their capacity on accurately reconstructing the elemental distribution is limited. Although algorithms specialized for XFCT reconstruction have been developed, the majority of them impose strict requirements on the samples and the acquisition setup. To relax these prerequisites, a deep convolutional neural network is proposed to correct the self-absorption effect in the sinogram domain. Through quantitative evaluation, we conclude that the well-trained neural network can correct fluorescence sinograms affected by the self-absorption effect. Furthermore, we demonstrate that such corrections enable conventional algorithms to reconstruct the elemental distribution with high fidelity. As the only input required by the proposed neural network is the fluorescence sinogram, it is fully automatic and is applicable to different scan setups and samples.
6 January 2021 in Analytical Chemistry