Luc Van Hoorebeke

Luc Van Hoorebeke

Auto-generated profile, based on publicly available information

Luc Van Hoorebeke

UGent Centre for X‐ray Tomography (UGCT) Ghent Belgium

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Environmental Pollution
Verified
Journal Article
Closed access
EDElisabeth Debusschere
Elisabeth Debusschere
KHKris Hostens
Kris Hostens
DADominique Adriaens
Dominique Adriaens
BABart Ampe
Bart Ampe
DBDick Botteldooren
Dick Botteldooren
SDSteven Degraer
Steven Degraer

1 October 1990 in Physical Review C
Verified
Journal Article
Closed access
PDF file
LHL. Van Hoorebeke
L. Van Hoorebeke
DRD. Ryckbosch
D. Ryckbosch
RVR. Van de Vyver
R. Van de Vyver
HFH. Ferdinande
H. Ferdinande
DND. Nilsson
D. Nilsson
KZK. Ziakas
K. Ziakas
Excitation-energy spectra resulting from the C12, O16, and Ca40(γ,p) reactions at 90° have been measured with tagged photons of about 61 and 77 MeV. Decay to several discrete states is discussed. Evidence is shown for an absorption process where the photon interacts with a T=1 proton-neutron pair, instead of the T=0 p-n pair implicit in the quasideuteron model.

14 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
FAFrederic Van Assche
Frederic Van Assche
SVSander Vanheule
Sander Vanheule
LHLuc Van Hoorebeke
Luc Van Hoorebeke
Matthieu BooneMatthieu Boone
Matthieu Boone
Photon counting X-ray imagers have found their way into the mainstream scientific community in recent years, and have become important components in many scientific setups. These camera systems are in active development, with output data rates increasing significantly with every new generation of devices. A different class of PCD (Photon Counting Detector) devices has become generally available, where camera data output is no longer a matrix of photon counts but instead direct measurements of the deposited charge per pixel in every frame, which requires significant off-camera processing. This type of PCD, called a hyperspectral X-ray camera due to its fully spectroscopic output, yet again increases the demands put on the acquisition and processing backend. Not only are bandwidth requirements increased, but the need to do extensive data processing is also introduced with these hyperspectral PCD devices. To cope with these new developments the Spectral X-ray Imaging Data Acquisition framework (SpeXIDAQ) has been developed. All aspects of the imaging pipeline are handled by the SpeXIDAQ framework: from detector control and frame grabbing, to processing, storage and live visualisation during experiments.

21 February 2010 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
BPBart Poffyn
Bart Poffyn
GSGwen ML Sys
Gwen ML Sys
GMGeorges Van Maele
Georges Van Maele
LHLuc Van Hoorebeke
Luc Van Hoorebeke
Ramses G. ForsythRamses G. Forsyth
Ramses G. Forsyth
DUDirk Uyttendaele
Dirk Uyttendaele

7 May 2015 in Sensors
Verified
Journal Article
Open access
PDF file
GCGabriele Chiesura
Gabriele Chiesura
GLGeert Luyckx
Geert Luyckx
EVEli Voet
Eli Voet
NLNicolas Lammens
Nicolas Lammens
WPWim Van Paepegem
Wim Van Paepegem
FBFrancis Berghmans
Francis Berghmans
Quality of embedment of optical fibre sensors in carbon fibre-reinforced polymers plays an important role in the resultant properties of the composite, as well as for the correct monitoring of the structure. Therefore, availability of a tool able to check the optical fibre sensor-composite interaction becomes essential. High-resolution 3D X-ray Micro-Computed Tomography, or Micro-CT, is a relatively new non-destructive inspection technique which enables investigations of the internal structure of a sample without actually compromising its integrity. In this work the feasibility of inspecting the position, the orientation and, more generally, the quality of the embedment of an optical fibre sensor in a carbon fibre reinforced laminate at unit cell level have been proven.

17 June 2019 in Materials
Verified
Journal Article
Open access
PDF file
RMRedouane Meftah
Redouane Meftah
JSJeroen Filip Van Stappen
Jeroen Filip Van Stappen
SBSylvain Berger
Sylvain Berger
GJGary Jacqus
Gary Jacqus
JLJean-Yves Laluet
Jean-Yves Laluet
Veerle CnuddeVeerle Cnudde
Veerle Cnudde
Expanded polystyrene (EPS) foam is widely used in building and construction applications for thermal and acoustic insulation. This material is nearly transparent for X-rays, making it difficult to characterize its pore structure in 3D with X-ray tomography. Because of this difficulty, the pore network is often not investigated and is, thus, poorly known. Since this network controls different physical properties, such as the sound absorption, it is crucial to understand its overall structure. In this manuscript, we show how to reveal the pore network of EPS foams through the combination of high resolution X-ray tomography (micro-CT) and saturation techniques. The foams were saturated with CsCl-brine, which acts as a contrasting agent in X-ray micro-CT imaging. This allowed us to separate the beads, making up the foam, from the pore network. Based on the 3D micro-CT results, we were able to assess a representative elementary volume for the polystyrene, which allows for calculating the acoustical parameters from the Johnson–Champoux–Allard (JCA) model, the pore and bead size distribution. The 3D data was also used as input to simulate sound absorption curves. The parametric study showed that an increase in the bead size influenced the sound absorption of the material. We showed that, by doubling the diameter of beads, the absorption coefficient was doubled in certain ranges of frequency.