Iván P. Román

Iván P. Román

Auto-generated profile, based on publicly available information

Iván P. Román

Analytical Chemistry, Nutrition and Food Science Department University of Alicante Alicante Spain

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


1 April 2011 in Analytica Chimica Acta
Verified
Journal Article
Closed access
APAikaterini Papadopoulou
Aikaterini Papadopoulou
IRIván P. Román
Iván P. Román
Antonio CanalsAntonio Canals
Antonio Canals
KTKonstantina Tyrovola
Konstantina Tyrovola
Elefteria PsillakisElefteria Psillakis
Elefteria Psillakis

1 February 2014 in Journal of Chromatography A
Verified
Journal Article
Closed access
IRIván P. Román
Iván P. Román
AMAnna Mastromichali
Anna Mastromichali
KTKonstantina Tyrovola
Konstantina Tyrovola
Antonio CanalsAntonio Canals
Antonio Canals
Elefteria PsillakisElefteria Psillakis
Elefteria Psillakis

9 November 2012 in Journal of Agricultural and Food Chemistry
Verified
Journal Article
Closed access
IFIván P. Román Falcó
Iván P. Román Falcó
NTNuria Grané Teruel
Nuria Grané Teruel
María Soledad SoledadMaría Soledad Soledad
María Soledad Soledad
MCM. Luisa Martín Carratalá
M. Luisa Martín Carratalá

10 July 2012 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
VSVioleta Milenkova Stefanova
Violeta Milenkova Stefanova
DGDeana Georgieva
Deana Georgieva
VKVeselin Kmetov
Veselin Kmetov
IRIvan Roman
Ivan Roman
Antonio CanalsAntonio Canals
Antonio Canals
The applicability of MnFe2O4 nanoparticles as a new sorbent for group pre-concentration of V, Co, Ni, Cu, Zn, As, Se, Cd and Pb was investigated and compared with that of magnetite nanoparticles. A solid-phase extraction (SPE) of target analytes based on sorption of their hydrophobic complexes with ammonium pyrrolidine dithiocarbamate (APDC) on the surface of unmodified nanoparticles (NPs) was optimized. Magnetic NPs with retained metal complexes were easily separated from the bulk solution by a permanent magnet applied for 5 min. Analyte restoration in the final solution was accomplished by heating with 0.5 mL of 7 mol L−1 nitric acid. The obtained solutions were suitable for continuous nebulization in ICP-MS. Spectral and non-spectral matrix effects for urine analysis (direct and after SPE) were studied and adequate calibration strategies are suggested. Under optimized conditions the magnetically assisted SPE procedure enables enrichment of target analytes by factors of between 7.4 and 10, with linear dynamic ranges of 1–100 μg L−1 for V, Co, Ni, Cd, Pb and 10–1000 μg L−1 for Zn, As, Se and method detection limits in the interval 0.01–0.7 μg L−1. The relative standard deviations (RSD%, for 10 μg L−1 V, Co, Ni, Cd, Pb and for 100 μg L−1 Zn, As, Se, n = 6) were less than 5.5%. The accuracy of the method was evaluated by analysing urine certified reference material Seronorm™ Trace Elements Urine 201205 and obtained recoveries were in the range 85–109%. For correct determination of As and Se in urine, a preliminary microwave sample treatment with a mixture HNO3 + H2O2 was needed, but it led to a worsening of method detection limits. The developed method was successfully applied for analysis of human urine.