Dominik Pražák

Dominik Pražák

Auto-generated profile, based on publicly available information

Dominik Pražák

Czech Metrology Institute

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2019 in Accreditation and Quality Assurance
Verified
Journal Article
Open access
PDF file
DPDominik Pražák
Dominik Pražák
VSVáclav Sedlák
Václav Sedlák
ESEkrem Sınır
Ekrem Sınır
FPFrantišek Pluháček
František Pluháček
The new International System of Units (SI) came into force this May, and while the media and public attention are focused on the changes in the base units, there are also other changes introduced. One of them is the abolition of millimetre of mercury (mmHg). This simplifies the SI but also can cause problems to the patients which are extremely conservative user groups (although this unit is still supported by some other authoritative documents). Hence, it is necessary to increase awareness of both the medical doctor and the patients.

1 January 2013 in Measurement
Verified
Journal Article
Closed access
DPD. Pražák
D. Pražák
JZJaroslav Zuda
Jaroslav Zuda
JTJ. Tesař
J. Tesař
LPL. Peksa
L. Peksa
MVM. Vičar
M. Vičar

9 August 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
MVMartin Vičar
Martin Vičar
ZKZdeněk Krajíček
Zdeněk Krajíček
DPDominik Pražák
Dominik Pražák
VSVáclav Sedlák
Václav Sedlák
TGTomáš Gronych
Tomáš Gronych
JTJiří Tesař
Jiří Tesař
The Czech national standard of low gas flow is based on the dynamic gravimetry principle, defining the flow rate as the mass loss of gas from a pressure bottle which is continuously weighed. This weighing is performed in ambient atmosphere, which brings two problems. First, the buoyancy corrections are the main and unavoidable source of uncertainty. Second, condensation of the water vapor on the pressure bottle can occur, due to its cooling below dew point at higher flow rates. A weighing carried out in a hermetically closed atmosphere suppresses the problematic buoyancy effects. A weighing in a vacuum does the same, and also eliminates any danger of water condensation. The paper describes the hermetic and vacuum mode modifications together with the relevant uncertainty analyses.

1 January 2014 in Metrologia
Verified
Journal Article
Closed access
ZKZdeněk Krajíček
Zdeněk Krajíček
MBMercede Bergoglio
Mercede Bergoglio
KJKarl Jousten
Karl Jousten
POPierre Otal
Pierre Otal
WSWladimir Sabuga
Wladimir Sabuga
MVMartin Vičar
Martin Vičar

30 November 2022 in ACTA IMEKO
Verified
Journal Article
Open access
PDF file
DPDominik Pražák
Dominik Pražák
VSVítězslav Suchý
Vítězslav Suchý
MŠMarkéta Šafaříková-Pštroszová
Markéta Šafaříková-Pštroszová
KDKateřina Drbálková
Kateřina Drbálková
VSVáclav Sedlák
Václav Sedlák
VKVanco Kacarski
Vanco Kacarski
The eye-tonometers are the important medical devices with measuring function which are necessary for the screenings of the intraocular hypertension (a serious risk factor for the glaucoma). However, it is not an easy task to ensure their correct metrological traceability. There is needed not only a wide range of various equipment but also the relevant know-how. Hence, a training centre for this quantity was established at the Czech Metrology Institute (CMI) within the framework of a smart specialisation concept for the intraocular pressure (IOP) metrology. The paper briefly outlines its history, scope, methodologies and future development plans

19 August 2014 in EPJ Web of Conferences
Verified
Journal Article
Open access
PDF file
WSWladimir Sabuga
Wladimir Sabuga
DPD Pražak
D Pražak
TRThierry Rabault
Thierry Rabault
EPJ Web of Conferences, open-access proceedings in physics and related sciences