Xinlong Zheng

Xinlong Zheng

Auto-generated profile, based on publicly available information

Xinlong Zheng

Central South University, Changsha, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HHHua Han
Hua Han
XZXinlong Zheng
Xinlong Zheng
Zhangjie LiuZhangjie Liu
Zhangjie Liu
YSYao Sun
Yao Sun
ZLZhangjie Liu
Zhangjie Liu
XLXubin Liu
Xubin Liu
This paper proposes a fast fault diagnosis scheme to realize fault detection and classification with fewer sensors for ring bus DC microgrids. After the analysis on mechanisms of line faults in the microgrids, the measurements of the local converter, including the voltage of the DC-link capacitor and the output current, are used to detect pole-to-pole (PP) faults and pole-to-ground (PG) faults, employing the sum of multi-step difference. Based on the deviation between the estimate and the actual output voltages, a simple and effective fault classification method is proposed in this research. The detection results of two neighboring units are exchanged to locate the fault line with low bandwidth distributed communication. Apart from PP faults, PG faults in both poles can be detected and distinguished, sharing the voltage and current sensors with the controllers of the converters, and the construct cost of the system can be reduced. The performance of the proposed scheme in different cases has been tested in MATLAB/Simulink, including high impedance faults, close-in faults and signal with noises. Further, the effectiveness of the scheme is validated under Hardware-in-loop (HIL) platform.

9 April 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SCShimiao Chen
Shimiao Chen
YSYao Sun
Yao Sun
XHXiaochao Hou
Xiaochao Hou
XZXinlong Zheng
Xinlong Zheng
Zhangjie LiuZhangjie Liu
Zhangjie Liu
KSKai Sun
Kai Sun
Synchronization and power-sharing control are essential for islanded parallel inverters. Traditionally, droop control and other grid-forming control are the typical methods with voltage-supporting abilities. However, those methods only apply to systems with a certain line impedance. For the application of uninterruptible power supply (UPS) systems with near-zero line impedance, droop-controlled inverters are prone to loss of stability. To address this issue, this letter introduces a new first-order phase-lock-loop (PLL)-synchronized voltagesupporting control method for the islanded operation of parallel inverters in UPS systems. It is found that the first-order PLL is employed for frequency synchronization in islanded operation. Meanwhile, voltage support and power sharing can be guaranteed with modified current control. Experimental results validate the feasibility of the proposed method

24 September 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HLHongyi Liu
Hongyi Liu
HHHua Han
Hua Han
XZXinlong Zheng
Xinlong Zheng
WLWeiwei Li
Weiwei Li
TLTao Ling
Tao Ling
YSYao Sun
Yao Sun
For dc microgrids (DCMGs) with short transient time, sharp current rise, and weak overcurrent capacity, accurate line fault localization is crucial for scheduling maintenance tasks and accelerating system recovery. In this article, a decentralized offline line fault localization method within the framework of fewer sensors is proposed. It does not rely on communication or the current and voltage of the faulty line, which contributes to reducing localization costs and improving protection reliability. The single-end converter bus-side voltage and positive pole current shared with the local controller are adopted. First, a discrete wavelet transform based feature extraction method is adopted to extract the weak positive pole current characteristics of negative pole-to-ground faults. Subsequently, an Att-GRU data augmentation method that integrates the attention mechanism (Att) and gate recurrent unit model (GRU) is presented to solve the problemsof few available fault samples. Furthermore, an ELM-Adaboost localization model combining extreme learning machine (ELM) and adaptive boosting algorithm (Adaboost) is presented to capture the complex nonlinear relationship between fault features and fault location. Finally, the effectiveness of the proposed method has been verified by MATLAB/Simulink and experimental tests.

3 April 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HHHua Han
Hua Han
XTXinwei Tang
Xinwei Tang
HLHongyi Liu
Hongyi Liu
ZWZhenxi Wu
Zhenxi Wu
WLWeiwei Li
Weiwei Li
CTChi K. Tse
Chi K. Tse
Threshold-based fault diagnosis methods are widely used in DC microgrid line protection owing to their rapid response. However, existing threshold settings still rely primarily on simulation tuning and empirical trials, which limit interpretability and general applicability. To overcome these limitations, this article proposes a unified threshold-based fault diagnosis framework for pole-to-pole (PP) and pole-to-ground (PG) faults in DC microgrids. First, a multiple mean skewness deviation (MMSD)-based fault feature extraction algorithm is developed to capture the statistical and distributional characteristics of fault filter capacitor (FC) currents without requiring high-frequency sampling. Then, faults are rapidly detected by comparing MMSD feature differences with a unified threshold, simplifying the diagnostic process while enhancing reliability and accuracy. Furthermore, a single-ended differential fault classification strategy based on bipolar current features is introduced, enabling accurate fault identification for a wide range of fault resistances within 1 ms. Simulation and experimental results validate the proposed method’s effectiveness, robustness, and adaptability, offering a practical solution for fast and reliable DC microgrid protection.