Hongyi Liu

Hunan Provincial Key Laboratory of Intelligent Control and Maintenance for Complex Systems, Hunan University of Science and Technology, Xiangtan, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
WLWeiwei Li
Weiwei Li
HHHua Han
Hua Han
YSYao Sun
Yao Sun
SCShimiao Chen
Shimiao Chen
HLHongyi Liu
Hongyi Liu
JZJin Zhao
Jin Zhao
The diversity of line fault types, the uncertainty of fault resistances, the limitation of available fault information, and the similarity of positive pole currents under different work conditions challenge the fault diagnosis of DC microgrids. This paper proposes a double threshold fault diagnosis scheme for line faults with wide-range fault resistances only using local fault currents such as bus-side capacitor current and positive pole line current. One threshold is designed based on the bus-side capacitor current estimation through the bus-side capacitor voltage to detect low-resistance faults rapidly. The other threshold is designed based on a proposed weighted correlation coefficient between the bus-side capacitor current and positive pole line current to detect high-resistance faults under noise accurately. All types of line faults can be classified accurately in 1.5 ms based on the positive pole output current and the ratio of the bus-side capacitor current to the variation value of the positive pole output current. The proposed scheme improves the reliability and economy of fault diagnosis by only using positive pole information and non-real-time communication. Finally, the feasibility of the proposed fault diagnosis scheme is verified by simulations and experiments.

29 January 2024 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
HLHongyi Liu
Hongyi Liu
HHHua Han
Hua Han
XZXinlong Zheng
Xinlong Zheng
YSYao Sun
Yao Sun
Zhangjie LiuZhangjie Liu
Zhangjie Liu
XLXubin Liu
Xubin Liu
The lack of relevant protection schemes and standards brings significant challenges to the promotion of direct current microgrid (DCMG) technologies. The existing line fault diagnosis methods usually require additional measuring devices to obtain fault signals. Although reducing the number of sensors can lower the system costs, it also increases the difficulty of diagnosis. Pole-to-pole (PP) and positive pole-to-ground (PPG) fault classification under unknown fault resistance, and negative-to-ground (NPG) fault detection under unobvious positive pole current characteristics are two major difficulties. To solve the above issues, a fuzzy granulation interval (FGI) theory-based line fault diagnosis method is proposed in this paper. Only locally measured bus-side voltage and positive pole current signals shared with the converter controller inputs are required. Firstly, the fault characteristics and diagnosis difficulties are analyzed. Then a new NPG fault index interval range (IR) is designed to extract the abnormal post-fault voltage fluctuations. Moreover, the PP/PPG fault classification strategy is designed according to the interval characteristics and capacitor discharge process. Finally, the performance of the proposed method has been evaluated through MATLAB/Simulink simulations and hardware-in-the-loop (HIL) tests. The results demonstrate that the proposed method can accurately discriminate different line faults within 1.5 ms under different fault conditions.

16 November 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HHHua Han
Hua Han
XZXinlong Zheng
Xinlong Zheng
Zhangjie LiuZhangjie Liu
Zhangjie Liu
YSYao Sun
Yao Sun
ZLZhangjie Liu
Zhangjie Liu
XLXubin Liu
Xubin Liu
This paper proposes a fast fault diagnosis scheme to realize fault detection and classification with fewer sensors for ring bus DC microgrids. After the analysis on mechanisms of line faults in the microgrids, the measurements of the local converter, including the voltage of the DC-link capacitor and the output current, are used to detect pole-to-pole (PP) faults and pole-to-ground (PG) faults, employing the sum of multi-step difference. Based on the deviation between the estimate and the actual output voltages, a simple and effective fault classification method is proposed in this research. The detection results of two neighboring units are exchanged to locate the fault line with low bandwidth distributed communication. Apart from PP faults, PG faults in both poles can be detected and distinguished, sharing the voltage and current sensors with the controllers of the converters, and the construct cost of the system can be reduced. The performance of the proposed scheme in different cases has been tested in MATLAB/Simulink, including high impedance faults, close-in faults and signal with noises. Further, the effectiveness of the scheme is validated under Hardware-in-loop (HIL) platform.

25 November 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HLHongyi Liu
Hongyi Liu
HHHua Han
Hua Han
GSGuangze Shi
Guangze Shi
XCXida Chen
Xida Chen
YSYao Sun
Yao Sun
CCChao-Yang Chen
Chao-Yang Chen
Line short-circuit faults diagnosis in dc microgrids (dcMGs) requires high rapidity and reliability due to their low inertia and weak overcurrent capability. At present, threshold-based diagnosis methods are popular due to their fast diagnosis speed and ease of employment. However, the existing diagnosis thresholds are usually fixed and determined by simulation and empirical analysis, which lack flexibility and adaptability. In addition, they usually depend on additional line current and/or voltage sensors, which may fail due to sensor faults. To solve the above issues, an adaptive threshold-based fault diagnosis method using information shared with the local converter controller is proposed. First, the difficulties of diagnosis threshold setting under fewer sensors are revealed. Second, the skewness, cumulative sum, and multistep derivatives of single-end converter bus-side current and voltage are selected as the fault features. Adaptive detection thresholds are designed to improve the accuracy and rapidity of line fault identification without line current/voltage sensors and communication links. Third, a modified fault classification method based on real-time calculated quantile interval and bus-side voltage estimation is presented. The accuracy and flexibility of line fault classification can be enhanced. Finally, the performance of the proposed method is validated through MATLAB/Simulink simulations and experimental tests.

24 September 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HLHongyi Liu
Hongyi Liu
HHHua Han
Hua Han
XZXinlong Zheng
Xinlong Zheng
WLWeiwei Li
Weiwei Li
TLTao Ling
Tao Ling
YSYao Sun
Yao Sun
For dc microgrids (DCMGs) with short transient time, sharp current rise, and weak overcurrent capacity, accurate line fault localization is crucial for scheduling maintenance tasks and accelerating system recovery. In this article, a decentralized offline line fault localization method within the framework of fewer sensors is proposed. It does not rely on communication or the current and voltage of the faulty line, which contributes to reducing localization costs and improving protection reliability. The single-end converter bus-side voltage and positive pole current shared with the local controller are adopted. First, a discrete wavelet transform based feature extraction method is adopted to extract the weak positive pole current characteristics of negative pole-to-ground faults. Subsequently, an Att-GRU data augmentation method that integrates the attention mechanism (Att) and gate recurrent unit model (GRU) is presented to solve the problemsof few available fault samples. Furthermore, an ELM-Adaboost localization model combining extreme learning machine (ELM) and adaptive boosting algorithm (Adaboost) is presented to capture the complex nonlinear relationship between fault features and fault location. Finally, the effectiveness of the proposed method has been verified by MATLAB/Simulink and experimental tests.

3 April 2026 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HHHua Han
Hua Han
XTXinwei Tang
Xinwei Tang
HLHongyi Liu
Hongyi Liu
ZWZhenxi Wu
Zhenxi Wu
WLWeiwei Li
Weiwei Li
CTChi K. Tse
Chi K. Tse
Threshold-based fault diagnosis methods are widely used in DC microgrid line protection owing to their rapid response. However, existing threshold settings still rely primarily on simulation tuning and empirical trials, which limit interpretability and general applicability. To overcome these limitations, this article proposes a unified threshold-based fault diagnosis framework for pole-to-pole (PP) and pole-to-ground (PG) faults in DC microgrids. First, a multiple mean skewness deviation (MMSD)-based fault feature extraction algorithm is developed to capture the statistical and distributional characteristics of fault filter capacitor (FC) currents without requiring high-frequency sampling. Then, faults are rapidly detected by comparing MMSD feature differences with a unified threshold, simplifying the diagnostic process while enhancing reliability and accuracy. Furthermore, a single-ended differential fault classification strategy based on bipolar current features is introduced, enabling accurate fault identification for a wide range of fault resistances within 1 ms. Simulation and experimental results validate the proposed method’s effectiveness, robustness, and adaptability, offering a practical solution for fast and reliable DC microgrid protection.