Roberto Alcázar

Roberto Alcázar

Auto-generated profile, based on publicly available information

Roberto Alcázar

Servicio de Nefrología, Hospital Universitario Infanta Leonor, Madrid, Spain

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 1997 in American Journal of Kidney Diseases
Verified
Journal Article
Closed access
RPRamón Peces
Ramón Peces
MTMiguel de la Torre
Miguel de la Torre
RARoberto Alcázar
Roberto Alcázar
JUJosém. Urra
Josém. Urra

14 February 2015 in BMC Nephrology
Verified
Journal Article
Open access
PDF file
MAMarta Albalate
Marta Albalate
RPRafael Pérez-García
Rafael Pérez-García
PSPatricia de Sequera
Patricia de Sequera
ECElena Corchete
Elena Corchete
RARoberto Alcazar
Roberto Alcazar
MPMarta Puerta
Marta Puerta
Increasing dialysate flow rates (Qd) from 500 to 800 ml/min has been recommended to increase dialysis efficiency. A few publications show that increasing Qd no longer led to an increase in mass transfer area coefficient (KoA) or Kt/V measurement. Our objectives were: 1) Studying the effect in Kt of using a Qd of 400, 500, 700 ml/min and autoflow (AF) with different modern dialysers. 2) Comparing the effect on Kt of water consumption vs. dialysis time to obtain an individual objective of Kt (Ktobj) adjusted to body surface. This is a prospective single-centre study with crossover design. Thirty-one patients were studied and six sessions with each Qd were performed. HD parameters were acquired directly from the monitor display: effective blood flow rate (Qbe), Qd, effective dialysis time (Te) and measured by conductivity monitoring, final Kt. We studied a total of 637 sessions: 178 with 500 ml/min, 173 with 700 ml/min, 160 with AF and 126 with 400 ml/min. Kt rose a 4% comparing 400 with 500 ml/min, and 3% comparing 500 with 700 ml/min. Ktobj was reached in 82.4, 88.2, 88.2 and 94.1% of patients with 400, AF, 500 and 700 ml/min, respectively. We did not find statistical differences between dialysers. The difference between programmed time and Te was 8′ when Qd was 400 and 500 ml/min and 8.8′ with Qd = 700 ml/min. Calculating an average time loss of eight minutes/session, we can say that a patient loses 24′ weekly, 312′ monthly and 62.4 hours yearly. Identical Kt could be obtained with Qd of 400 and 500 ml/min, increasing dialysis time 9.1′ and saving 20% of dialysate. Our data suggest that increasing Qd over 400 ml/min for these dialysers offers a limited benefit. Increasing time is a better alternative with demonstrated benefits to the patient and also less water consumption.

6 December 2024 in Nefrología (English Edition)
Verified
Journal Article
Open access
ACAleix Cases
Aleix Cases
JBJose Jesus Broseta
Jose Jesus Broseta
MVMaría Marques Vidas
María Marques Vidas
SGSecundino Cigarran Guldris
Secundino Cigarran Guldris
JMJuan Carlos Julián Mauro
Juan Carlos Julián Mauro
AOAlberto Ortiz
Alberto Ortiz

1 November 2002 in Resuscitation
Verified
Journal Article
Closed access
JOJulián Ortega-Carnicer
Julián Ortega-Carnicer
JBJuan Benezet
Juan Benezet
FRFrancisco Ruiz-Lorenzo
Francisco Ruiz-Lorenzo
RARoberto Alcázar
Roberto Alcázar

1 January 1995
Verified
Journal Article
Closed access
AOA Ortiz
A Ortiz
CBC Bustos
C Bustos
JAJ Alonso
J Alonso
RAR Alcázar
R Alcázar
MLMaría J López-Armada
María J López-Armada
JEJ Egido
J Egido

6 March 2014
Verified
Journal Article
Closed access
MGManuel Gorostidi
Manuel Gorostidi
RSRafael Santamaria
Rafael Santamaria
RARoberto Alcázar
Roberto Alcázar
GFGema Fernández-Fresnedo
Gema Fernández-Fresnedo
JGJosep M Galcerán
Josep M Galcerán
LRLuis M. Ruilope
Luis M. Ruilope