Christopher S. Campomizzi

Christopher S. Campomizzi

Auto-generated profile, based on publicly available information

Christopher S. Campomizzi

Department of Biochemistry, Jacobs School of Medicine and Biomedical Science, University at Buffalo, Buffalo, New York 14203, United States

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2024 in Cell Reports Physical Science
Verified
Journal Article
Open access
DADevrim Acehan
Devrim Acehan
KSKatherine A. Spoth
Katherine A. Spoth
GBGabrielle R. Budziszewski
Gabrielle R. Budziszewski
MSM. Elizabeth Snell
M. Elizabeth Snell
CCChristopher S. Campomizzi
Christopher S. Campomizzi
SBSarah Bowman
Sarah Bowman
Microcrystal electron diffraction (MicroED) is an emerging structural technique in which submicron crystals are used to generate diffraction data for structural studies. Structures allow for the study of molecular-level architecture and drive hypotheses about modes of action, mechanisms, dynamics, and interactions with other molecules. Combining cryoelectron microscopy (cryo-EM) instrumentation with crystallographic techniques, MicroED has led to three-dimensional structural models of small molecules, peptides, and proteins and has generated tremendous interest due to its ability to use vanishingly small crystals. In this perspective, we describe the current state of the field for MicroED methodologies, including making and detecting crystals of the appropriate size for the technique, as well as ways to best handle and characterize these crystals. Our perspective provides insight into ways to unlock the full range of potential for MicroED to access previously intractable samples and describes areas of future development.

17 July 2021
Verified
Book Chapter
Open access
PDF file
DED. Fernando Estrada
D. Fernando Estrada
AKAmit Kumar
Amit Kumar
CCChristopher S. Campomizzi
Christopher S. Campomizzi
NJNatalie Jay
Natalie Jay
The complex enzyme kinetics displayed by drug-metabolizing cytochrome P450 enzymes (CYPs) (see Chapter 9 ) can, in part, be explained by an examination of their crystallographic protein structures. Fortunately, despite low sequence similarity between different families of drug-metabolizing CYPs, there exists a high degree of structural homology within the superfamily. This similarity in the protein fold allows for a direct comparison of the structural features of CYPs that contribute toward differences in substrate binding, heterotropic and homotropic cooperativity, and genetic variability in drug metabolism. In this chapter, we first provide an overview of the nomenclature and the role of structural features that are common in all CYPs. We then apply these definitions to understand the different substrate specificities and functions in the CYP3A, CYP2C, and CYP2D families of enzymes.

21 February 2024 in Biochemistry
Verified
Journal Article
Closed access
CCChristopher S. Campomizzi
Christopher S. Campomizzi
PUPatil Pranita Uttamrao
Patil Pranita Uttamrao
JSJack J. Stallone
Jack J. Stallone
TRThenmalarchelvi Rathinavelan
Thenmalarchelvi Rathinavelan
DED. Fernando Estrada
D. Fernando Estrada

28 March 2023 in ACS Infectious Diseases
Verified
Journal Article
Closed access
CCChristopher S. Campomizzi
Christopher S. Campomizzi
AKAmit Kumar
Amit Kumar
PUPatil Pranita Uttamrao
Patil Pranita Uttamrao
JSJack J. Stallone
Jack J. Stallone
GGGeorge E. Ghanatios
George E. Ghanatios
DED. Fernando Estrada
D. Fernando Estrada

17 June 2025 in bioRxiv
Verified
Preprint
Open access
CCChristopher S. Campomizzi
Christopher S. Campomizzi
MSM. Elizabeth Snell
M. Elizabeth Snell
HMHalina Mikolajek
Halina Mikolajek
JSJames Sandy
James Sandy
JSJuan Sanchez-Weatherby
Juan Sanchez-Weatherby
SBSarah Bowman
Sarah Bowman
Room-temperature (RT) X-ray diffraction experiments enable us to investigate protein dynamics, efficiently probe fragment binding, and perform time-resolved crystallography experiments. The Versatile Macromolecular Crystallography in-situ (VMXi) beamline at Diamond Light Source (DLS) in the United Kingdom specializes in the collection of RT X-ray diffraction data in situ directly from crystallization trays without any manipulation of protein crystals, improving crystal integrity for fragile crystals. While many X-ray sources are now equipped to grow crystals on site for in-situ experiments, to date there has been no comprehensive analysis that we are aware of on the effect of shipping crystals on plates at ambient temperature for RT data collection, while the equivalent methodology for cryo-cooled crystals is well established. Here we examine the impact of shipping on crystals grown on MiTeGen In Situ-1 plates at the University of Buffalo Hauptman Woodward Research Institute (UB-HWI) in Buffalo, NY, United States transatlantic to DLS in Didcot, United Kingdom. We utilized the Stanford Synchrotron Radiation Lightsource (SSRL) Blue Box Thermal Shipper (Blue Box), which can maintain temperature for up to 168 hours, to ship crystallization plates at room temperature from UB-HWI to DLS. We hypothesized that long-distance shipping might compromise data quality through mechanical stress or temperature fluctuations. Instead, we found that room-temperature data collected at VMXi showed no significant differences for crystals set up at UB-HWI and shipped relative to crystals set up on site in the UK. High-resolution structures were successfully determined for all proteins in the study, demonstrating that long-distance shipment of crystals at non-cryogenic temperatures is feasible without compromising diffraction quality. This study provides a proof-of-concept workflow for expanding access to room-temperature crystallography worldwide, enabling more researchers to leverage cutting-edge techniques without needing to grow crystals on site.