Katherine A. Spoth

Katherine A. Spoth

Auto-generated profile, based on publicly available information

Katherine A. Spoth

Department of Structural Biology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, The State University of New York, Buffalo, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2025 in Nature Methods
Verified
Journal Article
Open access
PDF file
YYYue Yu
Yue Yu
KSKatherine A. Spoth
Katherine A. Spoth
MCMichael Colletta
Michael Colletta
KNKayla X. Nguyen
Kayla X. Nguyen
SZSteven E. Zeltmann
Steven E. Zeltmann
LKLena F. Kourkoutis
Lena F. Kourkoutis
Cryogenic electron microscopy is a powerful tool in structural biology. In thick specimens, challenges arise as an exponentially larger fraction of the transmitted electrons lose energy from inelastic scattering and can no longer be properly focused as a result of chromatic aberrations in the post-specimen optics. Rather than filtering out the inelastic scattering at the price of reducing potential signal, as is done in energy-filtered transmission electron microscopy, we show how a dose-efficient and unfiltered image can be rapidly obtained using tilt-corrected bright-field scanning transmission electron microscopy data collected on a pixelated detector. Enhanced contrast and a 3–5× improvement in dose efficiency are observed for two-dimensional images of intact bacterial cells and large organelles using tilt-corrected bright-field scanning transmission electron microscopy compared to energy-filtered transmission electron microscopy for thicknesses beyond 500 nm. As a proof of concept for the technique’s performance in structural determination, we present a single-particle analysis map at sub-nanometer resolution for a highly symmetric virus-like particle determined from 789 particles.

19 November 2015 in Journal of Liposome Research
Verified
Journal Article
Closed access
PDF file
MWMichael E. Wagner
Michael E. Wagner
KSKatherine A. Spoth
Katherine A. Spoth
LKLena F. Kourkoutis
Lena F. Kourkoutis
SRSyed Rizvi
Syed Rizvi
Niosomes were prepared using a novel supercritical carbon dioxide based method to simultaneously encapsulate ferrous sulfate and vitamin D3 as hydrophilic and hydrophobic cargo, respectively. Vesicle particle size was determined to be bimodal with peak diameters of 1.44 ± 0.16 μm and 7.21 ± 0.64 μm, with the smaller peak comprising 98.8% of the total niosomal volume. Encapsulation efficiency of ferrous sulfate was 25.1 ± 0.2% and encapsulation efficiency of vitamin D3 was 95.9 ± 1.47%. Physical stability of the produced niosomes was assessed throughout a storage period of 21 days. Niosomes showed good physical stability at 20 °C, but storage at 4 °C showed an initial burst release, indicating possible rupture of the niosomal membrane. The Korsmeyer–Peppas equation was used to model the release of ferrous sulfate over time at both storage temperatures.

7 September 2021 in IUCrJ
Verified
Journal Article
Open access
PDF file
TETyler Engstrom
Tyler Engstrom
JCJonathan Alan Clinger
Jonathan Alan Clinger
KSKatherine A. Spoth
Katherine A. Spoth
OCOliver B. Clarke
Oliver B. Clarke
DCDavid S. Closs
David S. Closs
RTRobert E. Thorne
Robert E. Thorne
Based on work by Dubochet and others in the 1980s and 1990s, samples for single-particle cryo-electron microscopy (cryo-EM) have been vitrified using ethane, propane or ethane/propane mixtures. These liquid cryogens have a large difference between their melting and boiling temperatures and so can absorb substantial heat without formation of an insulating vapor layer adjacent to a cooling sample. However, ethane and propane are flammable, they must be liquified in liquid nitrogen immediately before cryo-EM sample preparation, and cryocooled samples must be transferred to liquid nitrogen for storage, complicating workflows and increasing the chance of sample damage during handling. Experiments over the last 15 years have shown that cooling rates required to vitrify pure water are only ∼250 000 K s−1, at the low end of earlier estimates, and that the dominant factor that has limited cooling rates of small samples in liquid nitrogen is sample precooling in cold gas present above the liquid cryogen surface, not the Leidenfrost effect. Using an automated cryocooling instrument developed for cryocrystallography that combines high plunge speeds with efficient removal of cold gas, we show that single-particle cryo-EM samples on commercial grids can be routinely vitrified using only boiling nitrogen and obtain apoferritin datasets and refined structures with 2.65 Å resolution. The use of liquid nitrogen as the primary coolant may allow manual and automated workflows to be simplified and may reduce sample stresses that contribute to beam-induced motion.

22 April 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
YYYue Yu
Yue Yu
KSKatherine A. Spoth
Katherine A. Spoth
MCMichael Colletta
Michael Colletta
KNKayla X. Nguyen
Kayla X. Nguyen
SZSteven E. Zeltmann
Steven E. Zeltmann
LKLena F. Kourkoutis
Lena F. Kourkoutis
Cryo-EM is a powerful tool in structural biology, providing insights through techniques like single-particle analysis (SPA) and cryogenic electron tomography (cryo-ET). In thick specimens, challenges arise as an exponentially larger fraction of the transmitted electrons lose energy from inelastic scattering and can no longer be properly focused as a result of chromatic aberrations in the post-specimen optics. Rather than filtering out the inelastic scattering at the price of reducing potential signal, as is done in energy-filtered transmission electron microscopy (EFTEM), we show how a dose-efficient and unfiltered image can be rapidly obtained using tilt-corrected bright-field scanning-TEM (tcBF-STEM) data collected on a pixelated detector. Enhanced contrast and a 3-5x improvement in collection efficiency are observed for 2D images of intact bacterial cells and large organelles using tcBF-STEM compared to EFTEM for thicknesses beyond 500 nm. As a proof of concept for the technique’s performance in structural determination, we present an SPA map at subnanometer resolution for a highly symmetric virus-like particle (VLP) with 789 particles. These findings suggest applications for tcBF-STEM in cryo-EM of thicker cellular volumes where current approaches struggle.

23 May 2024 in Cell Reports Physical Science
Verified
Journal Article
Open access
DADevrim Acehan
Devrim Acehan
KSKatherine A. Spoth
Katherine A. Spoth
GBGabrielle R. Budziszewski
Gabrielle R. Budziszewski
MSM. Elizabeth Snell
M. Elizabeth Snell
CCChristopher S. Campomizzi
Christopher S. Campomizzi
SBSarah Bowman
Sarah Bowman
Microcrystal electron diffraction (MicroED) is an emerging structural technique in which submicron crystals are used to generate diffraction data for structural studies. Structures allow for the study of molecular-level architecture and drive hypotheses about modes of action, mechanisms, dynamics, and interactions with other molecules. Combining cryoelectron microscopy (cryo-EM) instrumentation with crystallographic techniques, MicroED has led to three-dimensional structural models of small molecules, peptides, and proteins and has generated tremendous interest due to its ability to use vanishingly small crystals. In this perspective, we describe the current state of the field for MicroED methodologies, including making and detecting crystals of the appropriate size for the technique, as well as ways to best handle and characterize these crystals. Our perspective provides insight into ways to unlock the full range of potential for MicroED to access previously intractable samples and describes areas of future development.

29 August 2024 in Research Square
Verified
Preprint
Open access
PDF file
YYYue Yu
Yue Yu
KSKatherine Spoth
Katherine Spoth
MCMichael Colletta
Michael Colletta
KNKayla Nguyen
Kayla Nguyen
SZSteven Zeltmann
Steven Zeltmann
LKLena Kourkoutis
Lena Kourkoutis
Cryo-EM is a powerful tool in structural biology, providing insights through techniques like single-particle analysis (SPA) and cryogenic electron tomography (cryo-ET). In thick specimens, challenges arise as an exponentially larger fraction of the transmitted electrons lose energy from inelastic scattering and can no longer be properly focused as a result of chromatic aberrations in the post-specimen optics. Rather than filtering out the inelastic scattering at the price of reducing potential signal, as is done in energy-filtered transmission electron microscopy (EFTEM), we show how a dose-efficient and unfiltered image can be rapidly obtained using tilt-corrected bright-field scanning-TEM (tcBF-STEM) data collected on a pixelated detector. Enhanced contrast and a 3-5x improvement in collection efficiency are observed for 2D images of intact bacterial cells and large organelles using tcBF-STEM compared to EFTEM for thicknesses beyond 500 nm. As a proof of concept for the technique’s performance in structural determination, we present an SPA map at subnanometer resolution for a highly symmetric virus-like particle (VLP) with 789 particles. These findings suggest applications for tcBF-STEM in cryo-EM of thicker cellular volumes where current approaches struggle.