1 February 1999 in Clinical Neurophysiology
1 February 1999 in Clinical Neurophysiology
1 February 2006 in Review of Scientific Instruments
We developed a prototype of a mobile, high-resolution, multichannel magnetoencephalography (MEG) system, called babySQUID, for assessing brain functions in newborns and infants. Unlike electroencephalography, MEG signals are not distorted by the scalp or the fontanels and sutures in the skull. Thus, brain activity can be measured and localized with MEG as if the sensors were above an exposed brain. The babySQUID is housed in a moveable cart small enough to be transported from one room to another. To assess brain functions, one places the baby on the bed of the cart and the head on its headrest with MEG sensors just below. The sensor array consists of 76 first-order axial gradiometers, each with a pickup coil diameter of and a baseline of , in a high-density array with a spacing of center-to-center. The pickup coils are below the outer surface of the headrest. The short gap provides unprecedented sensitivity since the scalp and skull are thin (as little as altogether) in babies. In an electromagnetically unshielded room in a hospital, the field sensitivity at was . The noise was reduced from at using a reference cancellation technique and further to using a gradient common mode rejection technique. Although the residual environmental magnetic noise interfered with the operation of the babySQUID, the instrument functioned sufficiently well to detect spontaneous brain signals from babies with a signal to noise ratio (SNR) of as much as 7.6:1. In a magnetically shielded room, the field sensitivity was at and at without implementation of reference or gradient cancellation. The sensitivity was sufficiently high to detect spontaneous brain activity from a old baby with a SNR as much as 40:1 and evoked somatosensory responses with a bandwidth after as little as four averages. We expect that both the noise and the sensor gap can be reduced further by approximately half with a gain in SNR of about four. Thus, we conclude from the performance of the prototype that it should be feasible to improve the babySQUID to detect cortical activity in infants in real time with high spatial resolution.
1 December 2003 in The Journal of Physiology
A mathematical model was used to analyse the contributions of different types of ionic currents in the pyramidal cells of longitudinal CA3 slices to the magnetic fields and field potentials generated by this preparation. Murakami et al. recently showed that a model based on the work of Traub et al. provides a quantitatively accurate account of the basic features of three types of empirical data (magnetic fields outside the slice, extracellular field potentials within the slice and intracellular potentials within the pyramidal neurons) elicited by stimulations of the soma and apical dendrites. This model was used in the present study to compute the net current dipole moment (Q) due to each of the different voltage‐ and ligand‐gated channels in the cells in the presence of fast GABAA inhibition. These values of Q are proportional to the magnetic field and electrical potential far away from the slice. The intrinsic conductances were found to be more important than the synaptic conductances in determining the shape and magnitude of Q. Among the intrinsic conductances, the sodium (gNa) and delayed‐rectifier potassium (gK(DR)) channels were found to produce sharp spikes. The high‐threshold calcium channel (gCa) and C‐type potassium channel (gK(C)) primarily determined the overall current waveforms. The roles of gCa and gK(C) were independent of small perturbations in these channel densities in the apical and basal dendrites. A combination of gNa, gK(DR), gCa, and gK(C) accounted for most of the evoked responses, except for later slow components, which were primarily due to synaptic channels.
1 October 2002 in The Journal of Physiology
This study examined whether evoked magnetic fields and intra‐ and extracellular potentials from longitudinal CA3 slices of guinea‐pig can be interpreted within a single theoretical framework that incorporates ligand‐ and voltage‐sensitive conductances in the dendrites and soma of the pyramidal cells. The 1991 CA3 mathematical model of R. D. Traub is modified to take into account the asymmetric branching patterns of the apical and basal dendrites of the pyramidal cells. The revised model accounts for the magnitude and waveform of the bi‐ and triphasic magnetic fields evoked by somatic and apical stimulations, respectively, in the slice in the absence of fast inhibition (blocked by 0.1 mm picrotoxin). The revised model also accounts for selective effects of 4‐aminopyridine (4‐AP) and tetraethylammonium (TEA), which block the potassium channels of A and C type, respectively, on the slow wave of the magnetic fields. Furthermore, the model correctly predicts the laminar profiles of field potential as well as intracellular potentials in the pyramidal cells produced by two classes of cells ‐ those directly activated and those indirectly (synaptically) activated by the applied external stimulus. The intracellular potentials in this validated model reveal that the spikes and slow waves of the magnetic fields are generated in or near the soma and apical dendrites, respectively. These results demonstrate that a single theoretical framework couched within the modern concepts of cellular physiology provides a unified account of magnetic fields outside the slice, extracellular potentials within the slice and intracellular potentials of the pyramidal cells for CA3.