1 September 2016 in Review of Scientific Instruments
We developed a 375-channel, whole-head magnetoencephalography (MEG) system (“BabyMEG”) for studying the electrophysiological development of human brain during the first years of life. The helmet accommodates heads up to 95% of 36-month old boys in the USA. The unique two-layer sensor array consists of: (1) 270 magnetometers (10 mm diameter, ∼15 mm coil-to-coil spacing) in the inner layer, (2) thirty-five three-axis magnetometers (20 mm × 20 mm) in the outer layer 4 cm away from the inner layer. Additionally, there are three three-axis reference magnetometers. With the help of a remotely operated position adjustment mechanism, the sensor array can be positioned to provide a uniform short spacing (mean 8.5 mm) between the sensor array and room temperature surface of the dewar. The sensors are connected to superconducting quantum interference devices (SQUIDs) operating at 4.2 K with median sensitivity levels of 7.5 fT/√Hz for the inner and 4 fT/√Hz for the outer layer sensors. SQUID outputs are digitized by a 24-bit acquisition system. A closed-cycle helium recycler provides maintenance-free continuous operation, eliminating the need for helium, with no interruption needed during MEG measurements. BabyMEG with the recycler has been fully operational from March, 2015. Ongoing spontaneous brain activity can be monitored in real time without interference from external magnetic noise sources including the recycler, using a combination of a lightly shielded two-layer magnetically shielded room, an external active shielding, a signal-space projection method, and a synthetic gradiometer approach. Evoked responses in the cortex can be clearly detected without averaging. These new design features and capabilities represent several advances in MEG, increasing the utility of this technique in basic neuroscience as well as in clinical research and patient studies.
1 January 2014 in Frontiers in Human Neuroscience
Background: A major motivation in designing the new infant and child magnetoencephalography (MEG) system described in this manuscript is the premise that electrophysiological signatures (resting activity and evoked responses) may serve as biomarkers of neurodevelopmental disorders, with neuronal abnormalities in conditions such as autism spectrum disorder potentially detectable early in development. Whole-head MEG systems are generally optimized/sized for adults. Since magnetic field produced by neuronal currents decreases as a function of distance^2 and infants and young children have smaller head sizes, whole-head adult MEG systems do not provide optimal signal-to-noise in younger individuals. This spurred development of a whole-head infant and young child MEG system – Artemis 123. Methods: In addition to describing the instrument design, the focus of this manuscript is use of Artemis 123 to obtain auditory evoked and resting-state neuromagnetic data in young children. Data were collected from a 14-month female, an 18-month female, and a 48-month male. Phantom data are also provided to show localization accuracy. Results: Artemis 123 auditory data showed generalizability and reproducibility, with auditory responses observed in all participants. The auditory MEG measures were found to be manipulable, exhibiting sensitivity to tone frequency. Furthermore, there appeared to be a predictable sensitivity of evoked components to development, with latencies decreasing with age. Resting-state showed characteristic oscillatory activity. Finally, phantom data showed that dipole sources could be localized with an errorConclusions: Artemis 123 allows efficient recording of whole-head MEG in infants four years and younger. Future work will examine the feasibility of obtaining somatosensory and visual recordings in similar-age children as well as obtaining recordings from younger infants. Thus, Artemis 123 offers the promise of detecting earlier diagnostic signatures
1 February 2006 in Review of Scientific Instruments
We developed a prototype of a mobile, high-resolution, multichannel magnetoencephalography (MEG) system, called babySQUID, for assessing brain functions in newborns and infants. Unlike electroencephalography, MEG signals are not distorted by the scalp or the fontanels and sutures in the skull. Thus, brain activity can be measured and localized with MEG as if the sensors were above an exposed brain. The babySQUID is housed in a moveable cart small enough to be transported from one room to another. To assess brain functions, one places the baby on the bed of the cart and the head on its headrest with MEG sensors just below. The sensor array consists of 76 first-order axial gradiometers, each with a pickup coil diameter of and a baseline of , in a high-density array with a spacing of center-to-center. The pickup coils are below the outer surface of the headrest. The short gap provides unprecedented sensitivity since the scalp and skull are thin (as little as altogether) in babies. In an electromagnetically unshielded room in a hospital, the field sensitivity at was . The noise was reduced from at using a reference cancellation technique and further to using a gradient common mode rejection technique. Although the residual environmental magnetic noise interfered with the operation of the babySQUID, the instrument functioned sufficiently well to detect spontaneous brain signals from babies with a signal to noise ratio (SNR) of as much as 7.6:1. In a magnetically shielded room, the field sensitivity was at and at without implementation of reference or gradient cancellation. The sensitivity was sufficiently high to detect spontaneous brain activity from a old baby with a SNR as much as 40:1 and evoked somatosensory responses with a bandwidth after as little as four averages. We expect that both the noise and the sensor gap can be reduced further by approximately half with a gain in SNR of about four. Thus, we conclude from the performance of the prototype that it should be feasible to improve the babySQUID to detect cortical activity in infants in real time with high spatial resolution.
16 October 2015 in Frontiers in Neuroanatomy
Background: An understanding of the maturation of auditory cortex responses in typically developing infants and toddlers is needed to later identify auditory processing abnormalities in infants at risk for neurodevelopmental disorders. The availability of infant and young child magnetoencephalography (MEG) systems may now provide near optimal assessment of left and right hemisphere auditory neuromagnetic responses in young populations. To assess the performance of a novel whole-head infant MEG system, a cross-sectional study examined the maturation of left and right auditory cortex responses in children 6- to 50-months of age. Methods: Blocks of 1000Hz (1st and 3rd blocks) and 500Hz tones (2nd block) were presented while MEG data were recorded using an infant/young child biomagnetometer (Artemis 123). Data were obtained from 29 children (11 males; 6 months to 59 months). Latency measures were obtained for the first positive-to-negative evoked response waveform complex in each hemisphere. Latency and age associations as well as frequency and hemisphere latency differences were examined. For the 1000 Hz tone, measures of reliability were computed. Results: For the first response - a response with a ‘P2m’ topography - latencies decreased as a function of age. For the second response - a response with a ‘N2m’ topography - no N2m latency and age relationships were observed. A main effect of tone frequency showed earlier P2m responses for 1st 1000 Hz (150 ms) and 2nd 1000 Hz (148 ms) versus 500 Hz tones (162 ms). A significant main effect of hemisphere showed earlier N2m responses for 2nd 1000 Hz (226 ms) versus 1st 1000 Hz (241 ms) versus 500 Hz tones (265 ms). P2m and N2m interclass correlation coefficient latency findings were as follows: left P2m (0.72, p < 0.001), right P2m (0.84, p < 0.001), left N2m (0.77, p < 0.001), and right N2m (0.77, p < 0.01). Conclusions: Findings of strong age and latency associations, sensitivity to tone frequency, and good test-retest reliability support the viability of longitudinal infant MEG studies that include younger as well as older participants as well as studies examining auditory processing abnormalities in infants at risk for neurodevelopmental disorders.
1 October 2019 in AIP Advances
We investigated series arrays of closely spaced, planar long Josephson junctions for magnetic field transduction in Earth’s field, with a linear response and high dynamic range. The devices were fabricated from thin film high-temperature superconductor YBa2Cu3O7−δ (YBCO) thin films, using focused helium ion beam irradiation to create the Josephson barriers. Four series arrays, each consisting of several hundreds of long junctions, were fabricated and electrically tested. From fits of the current-voltage characteristics, we estimate the standard deviation in critical current to be around 25%. Voltage-magnetic field measurements exhibit a transfer function of 42 mV/mT and a linear response over a range of 303 μT at 71 K, resulting in a dynamic range of 124 dB.
6 April 2004 in Superconductor Science and Technology