Adam Kecskemeti

Adam Kecskemeti

Auto-generated profile, based on publicly available information

Adam Kecskemeti

Department of Inorganic and Analytical Chemistry, University of Debrecen, Debrecen, Hungary

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Analytica Chimica Acta
Verified
Journal Article
Closed access
AKAdam Kecskemeti
Adam Kecskemeti
AGAttila Gáspár
Attila Gáspár


1 April 2018 in Talanta
Verified
Journal Article
Closed access
AKAdam Kecskemeti
Adam Kecskemeti
AGAttila Gáspár
Attila Gáspár

15 March 2017 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
AKAdam Kecskemeti
Adam Kecskemeti
JBJozsef Bako
Jozsef Bako
ICIstvan Csarnovics
Istvan Csarnovics
Éva CsőszÉva Csősz
Éva Csősz
AGAttila Gáspár
Attila Gáspár

1 April 2020 in Analytica Chimica Acta
Verified
Journal Article
Closed access
CNCynthia Nagy
Cynthia Nagy
AKAdam Kecskemeti
Adam Kecskemeti
AGAttila Gáspár
Attila Gáspár

21 July 2020 in Food Additives & Contaminants: Part A
Verified
Journal Article
Closed access
ÁKÁdám Kecskeméti
Ádám Kecskeméti
CNCynthia Nagy
Cynthia Nagy
PBPatrícia Biró
Patrícia Biró
ZSZsuzsa Szabó
Zsuzsa Szabó
IPIstván Pócsi
István Pócsi
AGAttila Gáspár
Attila Gáspár
This paper demonstrates the development of an analytical method based on CE coupled to ESI-MS for the identification and quantification of fumonisin mycotoxins. Separation and detection parameters (pH of background electrolyte (BGE), organic modifier content, sheath liquid (SL) composition, MS mode and nebuliser pressure) were optimised. Ammonium formate/ammonia (pH = 9.5) with 10% ACN modifier was found the most suitable BGE. Positive mode MS was used for detection by scanning the m/z range of 400–1200. Separation was highly affected by the nebuliser pressure, a 25% improvement in peak resolution was achieved by applying the optimised parameters. The ‘dilute and shoot’ approach was applied to overcome disturbing effects caused by the matrix of fungi supernatant samples. The available sample volume affected the reproducibility of the measurements greatly: the scattering of peak intensities were between 4 and 11 RSD% instead of 27–195 RSD% for fumonisin B1 and fumonisin B2 when the available volume was ~200 µL instead of ~20 µL. Quantitative determinations were carried out in Fusarium verticillioides and Fusarium proliferatum culture supernatant (raw) and mycelium (cleaned up) samples. The optimised method enabled the detection of 11 fumonisins in Fusarium proliferatum inoculated rice samples; 2 of them were quantified based on external calibration and 4 other compounds with fumonisin-like formulas were detected. Graphical Abstract