Jae-Yong Kwon

Jae-Yong Kwon

Auto-generated profile, based on publicly available information

Jae-Yong Kwon

Electromagnetic Wave Metrology Group, Korea Research Institute of Standards and Science, Daejeon, South Korea

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2011 in Optics Express
Verified
Journal Article
Closed access
PDF file
DLDong-Joon Lee
Dong-Joon Lee
JKJae-Yong Kwon
Jae-Yong Kwon
NKNo-Weon Kang
No-Weon Kang
JWJohn F. Whitaker
John F. Whitaker
Highly stable electro-optic field probe with wide dynamic range is presented. The highly efficient electro-optic modulation mechanism--based on interference and field-induced phase retardations using a new embodiment with a relatively thick sensor crystal mounted on a fiber--is explained. The probe is calibrated up to 3.5 GHz through the use of a micro-TEM cell and a standard gain horn antenna, both devices in which the electric field may be calculated at the specific sensing location of an electro-optic probe. The field-calibrated sensor shows over 100 dB (≤ 1 V/m to > 100 kV/m) of linear dynamic range. Also, an issue with the instability of the sensors that often occurs in intense electric-field measurements associated with electro-optic crystals is overcome by a real-time, bias-control loop. The stabilized sensor performance and its potential use for (pulsed) high-power-microwave applications are discussed.

23 April 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
NKNo-Weon Kang
No-Weon Kang
JKJae-Yong Kwon
Jae-Yong Kwon
CCChihyun Cho
Chihyun Cho
JPJeong-Il Park
Jeong-Il Park
A measurement system for a millimeter-wave (mm-wave) antenna is presented here. The topologies of RF subsystems for antenna measurements are reviewed, and the optimum topology for a far-field antenna measurement range for mm-wave antennas is proposed. This topology minimizes the losses of both the Tx and local oscillator (LO) signal paths. In order to verify the proposed topology, a W-band antenna measurement system for a fully anechoic chamber 10 (W) m x 13 (L) m x 7.5 (H) m in size is designed and implemented. To provide the optimal LO input power, a test signal supply that compensates for the complicated losses in the LO signal path is also designed and implemented. The optimization procedure of the LO power is described. The performance of the W-band antenna measurement system is evaluated by measuring the complex reflection coefficient and far-field gain of an electro-formed standard gain horn antenna. The measurement results are compared with intercomparison results between National Measurement Institutes. The results are shown to be within accepted uncertainty levels.

3 March 2011 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JKJae-Yong Kwon
Jae-Yong Kwon
TKTae-Weon Kang
Tae-Weon Kang
JKJeong-Hwan Kim
Jeong-Hwan Kim
JKJin-Seob Kang
Jin-Seob Kang
We have developed a 3.5-mm coaxial microcalorimeter that will become a national power standard up to 26.5 GHz. Several core parts such as a thermostat, an adiabatic line, a thermopile, and reference standards are described in detail. Some measurement data are shown for a system performance check. A finite-element method simulation of the adiabatic line is shown. A model of the effect of the adiabatic line on thermopile measurement is introduced. Effective efficiency at selected frequencies is presented for the reference standards.

16 December 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YHYoung-Pyo Hong
Young-Pyo Hong
JKJae-Yong Kwon
Jae-Yong Kwon
IHIn-June Hwang
In-June Hwang
DLDong-Joon Lee
Dong-Joon Lee
We propose field-calibrated electro-optic probes that are designed for millimeter-wave 5G phased array antenna and Ka-band rectangular waveguide. A method to enhance the probes’ sensitivity and the practical limit for realization are presented. The fabricated probes are specifically minute enough to fit inside a standard millimeter-wave waveguide section for calibration in a minimally invasive way. The proposed calibration method is validated by analyzing the field invasiveness and through a simulation. Using a calibrated probe associated with a heterodyning probe control system, electric field distributions with absolute V/m scale from a millimeter-wave antenna are presented.

22 September 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
CCChihyun Cho
Chihyun Cho
TKTae-Weon Kang
Tae-Weon Kang
JKJae-Yong Kwon
Jae-Yong Kwon
HKHyunji Koo
Hyunji Koo
In this article, we present a novel method for estimating the parameters of residual models, which are widely used to evaluate the measurement uncertainty of the scattering parameters measured by a vector network analyzer (VNA). Conventionally, the parameters of the residual model are obtained using the ripple method with an air line, where the insulator that distinguishes the inner and outer lines of the coaxial line is air. However, due to inaccuracies caused by losses from air lines, the usable range of frequencies is limited. In addition, methods using the invariance property of the cross ratio of complex numbers result in overestimation because the maximum error boundary is calculated. Above all, since both methods estimate only the magnitude uncertainty, the phase uncertainty estimation is not rigorous, and the correlation between the magnitude and the phase cannot be estimated. In contrast, the proposed method calculates the parameters of the residual model directly from the calibration standards uncertainty, including the phase as well as magnitude, achieving the same result as the VNA error model. The proposed parameter estimation for residual models can also easily propagate to the uncertainty of other measurements since it can obtain the correlation between magnitude and phase as well as the cross frequency. In this article, we compared the parameters of the residual model using the proposed method, the conventional ripple method, and the invariance property of the cross ratio of complex numbers. For validation, the uncertainty obtained using the residual model with the proposed parameter estimation was compared to the results from the VNA error model. The two uncertainties showed excellent agreement for highly reflective and matched devices. Finally, we discuss how to effectively manage the calibration and measurement capabilities of scattering parameters using the proposed uncertainty evaluation method.

3 October 2011 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
DLDong-Joon Lee
Dong-Joon Lee
JKJae-Yong Kwon
Jae-Yong Kwon
NKNo-Weon Kang
No-Weon Kang
JWJohn F. Whitaker
John F. Whitaker
The spatial and temporal evolution of the propagating fields in the transition region between the reactive and radiating near-field distances of a standard gain horn antenna operating within the Ka-band are presented. Electric-field distributions with amplitude and phase information are measured with minimal invasiveness by a vector-stabilized, electrooptic field-imaging system. Acquiring a complete vector-imaging data set, a comprehensive near-field propagation chart-which shows the detailed field development at each wavelength plane with full phase progression-is presented for an antenna frequency of 30 GHz.