29 January 2021 in Measurement and Control
In this paper, the propagation of uncertainty on a nonlinear measurement model is presented using a higher-order Taylor series. As the derived formula is based on a Taylor series, it is necessary to compute the partial derivatives of the nonlinear measurement model and the correlation among the various products of the input variables. To simplify the approximation of this formula, most previous studies assumed that the input variables follow independent Gaussian distributions. However, in this study, we generate multivariate random variables based on copulas and obtain the covariances among the products of various input variables. By applying the derived formula to various cases regardless of the error distribution, we obtained the results that coincide with those of a Monte-Carlo simulation. To apply high-order Taylor expansion, the nonlinear measurement model should be continuous within the range of the input variables to allow for differentiation, and be an analytic function in order to be represented by a power series. This approach may replace some time-consuming Monte-Carlo simulations by choosing the appropriate order of the Taylor series, and can be used to check the linearity of the uncertainty.
19 October 2016 in IEEE Transactions on Microwave Theory and Techniques
A channel mismatch calibration method is proposed for use in time-interleaved digital real-time oscilloscope (DRTO) applications. Linear equations are derived using Fourier transforms of the separated signals from each of the time-interleaved analog-to-digital converters (TIADCs). Thus the errors in the TIADCs can be easily calibrated by inversion of a matrix, as opposed to most previous work where additional filters are employed. The calibration accuracy of the proposed method is limited only by the noise produced after the TIADC circuitry, while other methods depend on the filter design. A transfer function measurement method is then proposed for application to commercially available DRTOs. Two-tone signals are measured using DRTOs from various suppliers to validate the proposed method. The occurrence of signals at spurious frequencies is considerably reduced, as demonstrated by the calibrated results.
11 March 2015 in IEEE Transactions on Instrumentation and Measurement
This paper proposes an error vector magnitude (EVM) measurement method for a wideband code-division multiple-access source using a real-time oscilloscope. The EVM values are extracted from the measured waveform using a signal processing that finds the appropriate carrier phase and symbol timing. Measurement uncertainty is also evaluated based on a Monte Carlo simulation, where the errors from the real-time oscilloscope and the signal processing are taken into account. The measured EVM of a source at 900 MHz is (0.2586 ± 0.0040)%, (0.2617 ± 0.0060)%, and (0.2543 ± 0.0078)% at 95% confidence level when the real-time oscilloscope has a bandwidth of 2, 4, and 20 GHz, respectively.
11 December 2017 in Measurement Science and Technology
Impairments of analog-to-digital converters (ADCs) used in digital real-time oscilloscopes (DRTO) have caused inevitable signal distortions in measurements. To calibrate these errors with traceability, we propose a novel method that consists of two steps. First, each transfer function of the ADCs is measured using pulse trains from a photodiode calibrated up to 110 GHz. Each data set of the ADCs is superimposed to convert the repetitive pulse to a single pulse to solve the under-sampling problem of the separated data depending on each ADC. Then, the signals of the device under test (DUT) are also separated and superimposed depending on the ADCs, and they are calibrated in the frequency domain based on the measured transfer functions. After a calibration process, the data set is reconverted to the time domain to achieve traceable calibration. To verify our method, we have measured the output of another 70 GHz photodiode with a calibrated DRTO. In terms of results, time-interleaved errors are suppressed by more than 24 dB up to the bandwidth of the DRTO.
22 September 2022 in IEEE Transactions on Instrumentation and Measurement
In this article, we present a novel method for estimating the parameters of residual models, which are widely used to evaluate the measurement uncertainty of the scattering parameters measured by a vector network analyzer (VNA). Conventionally, the parameters of the residual model are obtained using the ripple method with an air line, where the insulator that distinguishes the inner and outer lines of the coaxial line is air. However, due to inaccuracies caused by losses from air lines, the usable range of frequencies is limited. In addition, methods using the invariance property of the cross ratio of complex numbers result in overestimation because the maximum error boundary is calculated. Above all, since both methods estimate only the magnitude uncertainty, the phase uncertainty estimation is not rigorous, and the correlation between the magnitude and the phase cannot be estimated. In contrast, the proposed method calculates the parameters of the residual model directly from the calibration standards uncertainty, including the phase as well as magnitude, achieving the same result as the VNA error model. The proposed parameter estimation for residual models can also easily propagate to the uncertainty of other measurements since it can obtain the correlation between magnitude and phase as well as the cross frequency. In this article, we compared the parameters of the residual model using the proposed method, the conventional ripple method, and the invariance property of the cross ratio of complex numbers. For validation, the uncertainty obtained using the residual model with the proposed parameter estimation was compared to the results from the VNA error model. The two uncertainties showed excellent agreement for highly reflective and matched devices. Finally, we discuss how to effectively manage the calibration and measurement capabilities of scattering parameters using the proposed uncertainty evaluation method.
3 July 2023 in IEEE Transactions on Instrumentation and Measurement
This article describes an established D-band waveguide impedance standard. The 8-term vector network analyzer (VNA) error model is used for our measurement system. A set of shims, a flush short, thru, and a reciprocal device are used as calibration standards to determine the error coefficients of the VNA error model. From the measured raw scattering parameters and dimensions of each shim, the error coefficients of the error model, the propagation constant of the shim, and the reflection coefficient of the flush short are found using a nonlinear optimization. Then, we evaluate the uncertainty in the scattering parameter measurement by combining the fitting uncertainty, the dimension uncertainty of the shims, and the random effects of the VNA into the residual uncertainty model. Finally, we calculate the calibration and measurement capabilities (CMCs) of our measurement system.