Meng Liu

Meng Liu

Auto-generated profile, based on publicly available information

Meng Liu

Electric Power Research Institute, State Grid Shandong Electric Power Company, Jinan, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
JLJiayi Liu
Jiayi Liu
Huihui SongHuihui Song
Huihui Song
CCChenyue Chen
Chenyue Chen
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
MLMeng Liu
Meng Liu
Yanbin QuYanbin Qu
Yanbin Qu
This paper presents an innovative passivity-based $L_{2}$ -gain performance $(L_{2}$ -GP) adaptive robust control method for the design of primary and secondary frequency control in the low-inertia microgrid with lines and the inverter-interfaced generation. First, by exploiting and analyzing the internal structural properties, the Port-controlled Kuramoto-Hamiltonian model with dissipation for the microgrid system is derived. Combining the dynamics of Kuramoto oscillators with energy viewpoints and following the physical features of dynamic energy coordination in the microgrid, an adaptive robust $L_{2}$ -GP decentralized secondary control is developed to guarantee frequency restoration and active power sharing. An adaptive mechanism is adopted to estimate the electrical parameters so that the parameter randomness can be overcome and fast transient response, high performance, and robust stability can be achieved. Via local measurements, the decentralized framework accordingly obviates the need of any communication links for information broadcast or exchange. Finally, the comprehensive case studies are presented to validate satisfactory performance under rapid randomness and flexibility during plug-and-play operations.

4 December 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
LLLi Li
Li Li
HSHuihui Song
Huihui Song
SWShitao Wang
Shitao Wang
MLMeng Liu
Meng Liu
SGSong Gao
Song Gao
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
The Andronov-Hopf based virtual oscillator control (AHO) is a novel nonlinear grid-forming (GFM) control strategy that has better dynamic performance compared with droop and virtual synchronous generator. However, the grid voltage drop can affect the synchronization between the AHO inverter and the grid. In extreme cases, the system may lack a stable operating point, leading to transient stability issues. This paper establishes a dynamic power angle model that takes into account the voltage characteristics of the inverter. Subsequently, the influence of AHO parameters on transient stability is analysed under current unconstrained operation, and the impacts of current limitation strategy are discussed. On this basis, a transient stability enhanced control strategy for AHO inverters is proposed from the perspective of optimizing voltage characteristics and compensating power setpoints (OVCP). A small-signal model is then established to analyse the stability of the proposed strategy. Finally, simulations and hardware-in-the-loop simulations based on RT-BOX are conducted to verify the effectiveness of the proposed transient stability enhanced control strategy.

29 November 2018 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
MLMeng Liu
Meng Liu
QGQiwei Guo
Qiwei Guo
GZGuohui Zhang
Guohui Zhang
JSJianjun Su
Jianjun Su
Air conditioning is a load with thermal inertia, and short time control will not cause an obvious negative impact on user power consumption. Compared with the traditional mini‐split‐type air conditioner, it has the advantages of flexible control method, strong controllability, large power of the monomer, and so on. This paper studies the application potential of emergency control of central air conditioning in safe and stable operation of large power grid. Firstly, the working principle of central air conditioner and the model of central air conditioning are introduced. On this basis, the emergency control strategy of central air conditioning is put forward. Furthermore, the control strategy of central air conditioning response control signal of safety and stability control or frequency deviation signal is put forward. Finally, a practical engineering case is given to illustrate the feasibility of the proposed strategy and its application in a large power grid.

23 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
TWTao Wang
Tao Wang
LHLi Hongshan
Li Hongshan
TWTaiyu Wang
Taiyu Wang
MLMeng Liu
Meng Liu
TZTong Zhu
Tong Zhu
Liu HongchenLiu Hongchen
Liu Hongchen
With the increasingly obvious DC characteristics at both ends of the source and load sides of the low-voltage distribution network, the application scenarios of low-voltage DC microgrid gradually appear. Compared with the AC system, the DC microgrid has the characteristics of low inertia, weak damping, and poor anti-disturbance capabilities, all of which are important for improving operational stability. A virtual inertia adaptive control approach for fast-tracking energy storage under varied disturbances is presented using energy storage as a virtual inertia unit. Firstly, a stability analysis model including constant power load is constructed for the low-voltage DC microgrid; then, the control logic of the virtual inertia of the energy storage system is designed. Finally, the corresponding model is built in MATLAB/SIMULINK and the experiment platform to verify the correctness and effectiveness of the proposed control strategy.

21 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
Ji HanJi Han
Ji Han
LLLi Li
Li Li
Huihui SongHuihui Song
Huihui Song
MLMeng Liu
Meng Liu
ZSZongxun Song
Zongxun Song
Yanbin QuYanbin Qu
Yanbin Qu
Wind farm (WF) equivalence is an effective method to achieve accurate and efficient simulation of large-scale WF. Existing equivalent models are generally suitable for one certain or very few scenarios, and have difficulty reflecting the multiple aspects of dynamic processes of WF. Aiming at these problems, this paper proposes an equivalent model of WF based on multivariate multi-scale entropy (MMSE) and multi-view clustering. Firstly, the influence of the factors on the dynamic process of the wind turbine (WT) is discussed, including control mode, wind speed and its wake effect, resistance of crowbar resistor and so on. The relationship between these factors and the dynamic equivalence of WF is analyzed. Secondly, an overview of MMSE is given, and the applicability of MMSE on WF equivalence is analyzed. On this basis, this paper proposes the extraction process of a WT clustering indicator using MMSE. Then, the multi-view fuzzy C means (MV-FCM) algorithm is used for the clustering of WTs, and the equivalent model of WF is obtained after calculating the equivalent parameters. Finally, the IEEE14 power system including WF is simulated. The results show that the equivalent model could be applied to dynamic process simulation in various fault scenarios of power systems, and the error is small when the cluster number is 4. Compared with the detailed model, the simulation time of the WF equivalent model proposed in this paper is shortened by 86%, and the simulation accuracy is improved by about 44% compared with the comparative model.

10 December 2018 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
MLMeng Liu
Meng Liu
LZLei Zheng
Lei Zheng
FSFangfang Shi
Fangfang Shi
KLKuan Li
Kuan Li
Switching AC filter may cause harmonic impact, which may lead to commutation failure of HVDC system. Here, the commutation failure mechanism of HVDC system caused by AC filter switching is studied. The circuit and mathematical model of the transient process simulation of filter switching are established, and the time‐domain solution of the overvoltage of each filter including voltage reduction and distortion is given. The commutation failure mechanism of HVDC system is analysed based on the commutation failure analysis method of harmonic voltage and time area. The simulation results verify the effectiveness of the mechanism analysis of commutation failure caused by AC filter switching in HVDC system.