Pilar Fernandez Pison

Pilar Fernandez Pison

Auto-generated profile, based on publicly available information

Pilar Fernandez Pison

CERN, 30531 Geneve Switzerland

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Engineering Fracture Mechanics
Verified
Journal Article
Closed access
PFP. Fernández-Pisón
P. Fernández-Pisón
JRJ.A. Rodríguez-Martínez
J.A. Rodríguez-Martínez
EGE. García-Tabarés
E. García-Tabarés
IAI. Avilés-Santillana
I. Avilés-Santillana
SSStefano Sgobba
Stefano Sgobba

9 December 2023 in Mechanics of Materials
Verified
Journal Article
Open access
PFP. Fernández-Pisón
P. Fernández-Pisón
AVA.R. Vishnu
A.R. Vishnu
GVG. Vadillo
G. Vadillo
JRJ.A. Rodríguez-Martínez
J.A. Rodríguez-Martínez

6 January 2026 in International Journal of Solids and Structures
Verified
Journal Article
Open access
PFP. Fernández-Pisón
P. Fernández-Pisón
LSL.M. Santana
L.M. Santana
QSQ. Sellam
Q. Sellam
VFV. Farrugia
V. Farrugia
YMY. Madi
Y. Madi
JBJ. Besson
J. Besson

6 March 2019 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
PPPilar Fernandez Pison
Pilar Fernandez Pison
SLStefanie A. E. Langeslag
Stefanie A. E. Langeslag
ISIgnacio Aviles Santillana
Ignacio Aviles Santillana
ADAlexander Dimitrijevic
Alexander Dimitrijevic
SSStefano Sgobba
Stefano Sgobba
BLByung Su Lim
Byung Su Lim
The development of new generation superconduct-ing magnets for fusion research, such as the ITER experiment, is largely based on coils wound from so-called “Cable-In-Conduit” Conductors (CICCs). CICCs consist of various types of stainless steel jackets, densely filled with compacted superconducting strands, which are cooled by supercritical helium. The design of the various magnet systems, and in particular the ITER Poloidal Field (PF) coils, imposes the use of electrical joints to connect unit lengths of the CICCs. The electrical joints are delicate, electrical resistive components, carefully designed to provide efficient high current transfer while avoiding heat generation. The PF joints are subjected to fast varying magnetic fields that induce currents which, combined with the Joule heating in the resistive joints due to transport current, increase the temperature of the helium. Various characteristics, including electrical per-formance and mechanical behavior, have been addressed in the past in order to optimize manufacturing for satisfactory joint op-eration. Here an extensive post-mortem characterization of pre-qualification full-size PF joints is reported. Void fraction, twist pitch and the current path connection are investigated in order to understand their effect on electrical performance and tune the manufacturing processes.

1 January 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SSStefano Sgobba
Stefano Sgobba
ISIgnacio Aviles Santillana
Ignacio Aviles Santillana
SLStefanie Agnes Elisabeth Langeslag
Stefanie Agnes Elisabeth Langeslag
PPPilar Fernandez Pison
Pilar Fernandez Pison
PMPaula Freijedo Menendez
Paula Freijedo Menendez
DHDuke Hughes
Duke Hughes
The Central Solenoid (CS) is the backbone of the ITER magnet system. It consists of six independent coils held together by a vertical pre-compression structure that must react tensile loads and provide sufficient preload to maintain coil-to-coil contact during all stages of plasma operation. Material selection and specifications applicable to the structural components of the pre-compression structure are particularly demanding. These include large forgings manufactured from a high strength austenitic stainless steel (FXM-19) with a stringent specification in terms of microstructure and maximum allowed magnetic permeability. Stringent requirements are also imposed on all welded joints. In particular, the attachment welds of the cooling pipes to the structure are subject to challenging restrictions in terms of weld imperfections and geometry. They must induce limited distortion of the components and are submitted to inspections carried out in accordance with the most severe acceptance levels of applicable standards. The results of extensive characterizations based on non-destructive and destructive evaluation of samples from different components and welds are reported in this paper, particularly focusing on the quality achieved at the microstructural and macrostructural level. The influence of the microstructure on the properties and on the inspectability of the material by non-destructive examinations is discussed.

13 April 2021 in engrXiv
Verified
Preprint
Open access
PFPilar Fernández-Pisón
Pilar Fernández-Pisón
JRJose Rodriguez-Martinez
Jose Rodriguez-Martinez
EGE. García-Tabares
E. García-Tabares
IAI. Avilés-Santillana
I. Avilés-Santillana
SSS. Sgobba
S. Sgobba
In this paper, we have characterized the microstructural evolution and the plastic flow and fracture behaviours of AISI 304L and AISI 316LN stainless steel grades at liquid nitrogen temperature (77 K) and at liquid helium temperature (4 K). Uninterrupted tensile experiments, where the sample is continuously deformed under quasi-static loading conditions until fracture, have been carried out with a Single-Section Sample to obtain the stress-strain characteristics of the two grades. Interrupted tensile experiments, in which the sample is unloaded before fracture, have been performed with a novel Double-Section Sample to later characterize the strain-induced martensitic transformation at different levels of deformation. The content of martensite has been determined post-mortem, using magnetic induction, electron backscatter diffraction and quantitative light optical micrography. The results obtained with the three methods show quantitative agreement, and reveal that the martensitic transformation in AISI 304L occurs faster and to a greater extent than in AISI 316LN both at 77 K and at 4 K. To the authors' knowledge, in this paper we provide the first experimental results for the evolution of the content of strain-induced martensite in AISI 304L and AISI 316LN samples tested at liquid helium temperature. In addition, the experimental data for the evolution of the martensite volume fraction with the strain have been used to identify the temperature-dependent parameters of the martensitic transformation kinetic models proposed by Olson and Cohen (1975) and Garion and Skoczen (2002). Moreover, Mode I fracture tests with fatigue-precracked Compact Samples have been carried out to determine the fracture properties of the two investigated materials using the "resistance curve procedure" (ASTM-E1820-20a, 2020). The crack-growth resistance curves have been obtained with four different methods here referred to as ASTM Compliance Method, W-N Compliance Method, Modified W-N Compliance Method and ASTM Normalization Method, which is an original methodological contribution of this paper. While the four approaches yield similar results for the fracture toughness, only the W-N Compliance Method and the Modified W-N Compliance Method, the latter being proposed in this paper, fulfil all the requirements of the standard ASTM-E1820-20a (2020) so that the calculated fracture toughness can be accepted as a material property. The comparison of results for both materials and testing temperatures shows that the AISI 316LN displays higher fracture toughness than the AISI 304L. Moreover, post-mortem microstructural analysis of the Compact Samples near the fracture surface has revealed that the content of martensite is greater in AISI 304L than in AISI 316LN. Furthermore, for AISI 304L more martensite is formed in the sample tested at 77 K because the plastic deformation near the crack is greater than at 4 K.