Ignacio Aviles Santillana

Dr. Ignacio Aviles Santillana

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2018 in Journal of Materials Engineering and Performance
Verified
Journal Article
Closed access
PDF file
ISIgnacio Aviles Santillana
Ignacio Aviles Santillana
CBC. Boyer
C. Boyer
PPP. Fernandez Pison
P. Fernandez Pison
AFA. Foussat
A. Foussat
SLS. A. E. Langeslag
S. A. E. Langeslag
SSS. Sgobba
S. Sgobba

23 January 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AMAlice Moros
Alice Moros
MCMickael Denis Crouvizier
Mickael Denis Crouvizier
ISIgnacio Aviles Santillana
Ignacio Aviles Santillana
SSStefano Sgobba
Stefano Sgobba
SBSusana Izquierdo Bermudez
Susana Izquierdo Bermudez
GVGiorgio Vallone
Giorgio Vallone
The design and production of Nb 3 Sn-based dipole and quadrupole magnets is critical for the realization of the High-Luminosity Large Hadron Collider (HL-LHC) at the European Organization for Nuclear Research (CERN). Nb 3 Sn superconducting coils are aimed at enhancing the bending and focusing strengths of accelerator magnets for HL-LHC and beyond. Due to the brittle nature of Nb 3 Sn, the coil fabrication steps are very challenging and require very careful QA/QC. Flaws in the Nb 3 Sn filaments may lead to quenches, and eventually, performance limitation below nominal during magnet testing. A novel inspection method, including advanced non-destructive and destructive techniques, was developed to explore the root-causes of quenches occurring in performance-limiting coils. The most relevant results obtained for MQXF coils through this innovative inspection method are presented. This approach allows for precise assessment of the physical events associated with the quenches experienced by magnet coils, mainly occurring in the form of damaged strands with transversely broken sub-elements. Coil-slice preparation, micro-optical observations of transverse and longitudinal cross-sections, and a deep etching technique of copper will be illustrated in the present work, with a focus on the results achieved for a CERN coil from a non-conforming quadrupole magnet prototype, and two coils fabricated in the US, in the framework of the Accelerator Upgrade Project (AUP) collaboration, from two different non-conforming quadrupole magnets, respectively. The results obtained through the proposed inspection method will be illustrated.

14 December 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
RPR. Piccin
R. Piccin
JRJ. S. Rigaud
J. S. Rigaud
ISIgnacio Aviles Santillana
Ignacio Aviles Santillana
KBK. E. Buchanan
K. E. Buchanan
DTD. Ternova
D. Ternova
CLC. Luongo
C. Luongo
Polyimide is often the first choice to insulate instrumentation and magnet wires working under demanding environmental and operating conditions since it shows good mechanical properties at low temperatures and high radiation resistance. Nevertheless, we have recently discovered that thermoplastic polyimide (TPI) insulated wires may suffer an accelerated brittle failure from a combination of environmental and mechanical stress, summarized as environmental stress cracking (ESC). Amorphous plastics immersed in an aggressive liquid and under a certain stress level, may develop crazes below the stress that would normally cause crazing in air. Certain alkaline hardeners can be considered aggressive toward polyimide. This study reports the causes and effects of environmental stress cracking of thermoplastic polyimide insulated wires subjected to resin systems commonly used in superconducting magnet technologies, and tentatively identifies those that seem more benign. We suspect that ESC can be behind some of the failures (Paschen breakdown under test voltages or even in operation) seen in some superconducting coils.

3 July 2024 in Superconductor Science and Technology
Verified
Journal Article
Closed access
ISIgnacio Aviles Santillana
Ignacio Aviles Santillana
SSS Sgobba
S Sgobba
MCM D Crouvizier
M D Crouvizier
ADA Devred
A Devred
GIG Arnau Izquierdo
G Arnau Izquierdo
ETE Todesco
E Todesco
The future of particle accelerators is strongly linked to the development of high—field magnets. The European Organization for Nuclear Research (CERN) is currently developing Nb3Sn-based magnets for the high-luminosity upgrade of the large hadron collider (HL-LHC), to fully exploit its potential and surpass the intrinsic performance limitations of Nb–Ti-based magnets. The fabrication of Nb3Sn magnets is a challenging process as it requires managing the brittle and strain sensitive conductor after the reaction heat treatment to generate the superconducting phase. Accelerator magnet coils are usually manufactured following the wind-react-and-impregnate fabrication process. This reduces the difficulty of working with brittle compounds but adds uncertainties associated with volume change during phase transition and thermal expansion/contraction differentials during the temperature ramps of the heat treatment and cooldown to cryogenic temperatures. To investigate the root causes of performance limitation or degradation observed on HL-LHC magnet prototypes, several Nb3Sn-based coils have been examined. The present paper illustrates an innovative methodology of investigations of the root causes at several fabrication stages and after cooldown and powering. The approach is based on a sequence of mesoscale observations of whole coil sections by an innovative high—energy linac x-ray computed tomography, followed by materialographic assessment of internal events, geometrical distortions and potential flaws using light microscopy. Additionally, scanning electron microscopy and focused ion beam were used to analyze damage at localized positions. This comprehensive approach provides an in-depth view of the examined coils by characterizing atypical features and imperfections in both the strands and the glass fiber/resin of the insulation system, univocally associating the limiting quenches experienced by the coils to identified physical events.

3 June 2024 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
RPRobert Pearce
Robert Pearce
JBJ. L. Bersier
J. L. Bersier
AIA. Iannetti
A. Iannetti
CJC. Jarrige
C. Jarrige
DKD. Kang
D. Kang
SSStefano Sgobba
Stefano Sgobba
The insulating vacuum within the ITER Cryostat has a prime purpose to minimize the heat load on the superconducting coil system by gas thermal conductivity. These coils are shielded from thermal radiation by an 80 K helium-cooled silver-coated thermal shield (TS) consisting of $\sim$ 500 panels. Leakage within a cryogenic circuit inside the cryostat is considered to be the prime risk to the ITER project’s mission, as leakage could be disabling to the operation of the magnet systems, be extremely challenging to localize and may be inaccessible for repair. To date, four leaks have been detected and localized within in-cryostat components delivered to ITER. Specifically, three of these leaks have been diagnosed within the TS cooling circuits as having been caused by chlorine-induced stress corrosion cracking (SCC). The technique of high-resolution X-ray computed tomography followed by precision cutting for the generation of macros and micros has been applied to successfully characterize small vacuum leaks for the first time. The techniques were further extended to nonleaking cooling pipes and the onset of SCC was observed in many places, indicating the high probability of the development of many thousands of leaks over time. Such analysis has led to the full replacement/repair program for the TSs before they become overly embedded into ITER. This article summarizes how the helium leakage risk is mitigated and details the detection of extensive SCC on the ITER TSs.
1

17 July 2018 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
LWLin Wang
Lin Wang
WWWeiyue Wu
Weiyue Wu
JWJing Wei
Jing Wei
YIYuri Ilyin
Yuri Ilyin
NDNello Dolgetta
Nello Dolgetta
L/Lin /Hiswang
Lin /Hiswang
The correction coils (CCs) are a system of 18 superconducting coils composed of top CCs, side CCs, and bottom CCs, and are required to correct asymmetries and reduce magnetic error fields detrimental to the plasma performance of the ITER machine. The CC terminals will be connected with those of the superconducting busbars with twin-box joints. Qualification of the manufacturing procedure of the coil terminals is achieved by performing electrical tests of prototype joints in relevant conditions of current, temperature, and background field (4.5 K, 10 kA, and 2.5 T). In order to control the dc resistance and ac loss in series production, special tooling and manufacturing processes were developed. The main technological steps are conductor dejacketing, nickel removal, and silvering of the cable in the terminal, followed by cable compaction and tungsten inert gas welding of the termination box. To this end, two joint samples were manufactured in 2015 and 2016. The performance of the joint samples was verified before and after 1000 electromagnetic cycles. The qualification tests were carried out in the SULTAN facility and ASIPP facility. The test results show the dc resistance below 5- $\text{n}\Omega $ criterion and ac losses below 7 J/cycle.