Christopher J. Swenson

Christopher J. Swenson

Auto-generated profile, based on publicly available information

Christopher J. Swenson

Plasma, Pulsed Power, and Microwave Laboratory, Department of Nuclear Engineering and Radiological Sciences, University of Michigan , Ann Arbor, Michigan 48109, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2021 in IEEE Transactions on Plasma Science
Verified
Journal Article
Open access
YLY. Y. Lau
Y. Y. Lau
DPDrew A. Packard
Drew A. Packard
CSChristopher J. Swenson
Christopher J. Swenson
JLJohn W. Luginsland
John W. Luginsland
DLDion Li
Dion Li
RGRonald M. Gilgenbach
Ronald M. Gilgenbach
This article re-examines the Brillouin flow solutions in crossed-field diodes, with applications to magnetrons, magnetically insulated line oscillators (MILOs), and magnetically insulated transmission lines (MITLs). The Brillouin flow solutions are constructed for various geometries, including planar magnetrons, MILOs, and MITLs, cylindrical magnetrons with electrons flowing in the azimuthal direction, cylindrical MITLs and MILOs with electrons flowing in the axial direction, and radial MITLs and MILOs with electrons flowing in the radial direction. A common theme of this analysis is that two main external parameters are used to characterize the Brillouin flow: the anode–cathode voltage ( $V_{a}$ ) and the total magnetic flux within the crossed-field diodes ( $A_{a}$ ). These two parameters are equivalent to the gap voltage and a specification of the degree of magnetic insulation, which is approximately equal to the ratio of the magnetic field to the Hull cutoff (HC) magnetic field. The magnetic flux may be provided externally by a magnet (as in a magnetron) or by the wall currents without an external magnet (as in a MILO or MITL), or by some combination of the two, as in the intermediate case of a magnetron–MILO hybrid. Once these two parameters are specified, the electron flow speed at the top of the Brillouin hub is uniquely determined. This immediately yields the Buneman–Hartree (BH) condition according to the Brillouin flow model, whether it be a planar magnetron or a cylindrical MILO. In so doing, we have obtained, for the first time using the Brillouin flow model, the BH condition for a cylindrical MILO, and we show that the same condition is obtained from the single-particle orbit model. We also found that, in general, the electron current within the Brillouin hub contributes only to a very small fraction of the magnetic flux $A_{a}$ , regardless of the gap voltage $V_{a}$ , thereby correcting an erroneous notion that the electron flow within the crossed-field gap could be responsible for the magnetic insulation. Another counter-intuitive finding is that, for a given degree of magnetic insulation, the Brillouin hub height decreases as the gap voltage $V_{a}$ increases. These conclusions, and other results, were based on the simple, explicit analytic expressions that we have obtained for the Brillouin flow profiles, including the velocity, electron density, as well as the self-magnetic field and the self-electric field profiles due to the Brillouin hub electrons. From these analytical expressions, we deduce useful scaling laws that are applicable to the prevailing cases where the magnetic field exceeds 1.5 times the HC magnetic field, and they are valid in both relativistic and non-relativistic regimes. Thus, these scaling laws show the contrast between magnetrons and MILOs, and a ready assessment of the viability of building a moderate-current MILO, a low-voltage MILO, and a magnetron–MILO hybrid which might combine the advantages of a magnetron and a MILO. The Brillouin flow profiles in a radial MITL are explicitly calculated. Additional issues are addressed.

1 December 2021 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
DPDrew A. Packard
Drew A. Packard
YLY. Y. Lau
Y. Y. Lau
EGE. N. Guerin
E. N. Guerin
CSC. J. Swenson
C. J. Swenson
SLS. V. Langellotti
S. V. Langellotti
RGR. M. Gilgenbach
R. M. Gilgenbach
The magnetically insulated line oscillator (MILO) is a high power microwave source that has received increased attention recently because it does not require an external magnetic field. Self-magnetic insulation typically requires operation at high currents, ∼50 kA in previous experiments (at ∼10 Ω). This paper reports the first MILO experiment operating at moderate current, less than 10 kA, at a lower voltage of 240 kV, driven by the Michigan Electron Long Beam Accelerator. The viability of this lower current operation was predicted by our recently developed theory on Brillouin flow, which also led to the rigorous derivation, for the first time, of the Buneman–Hartree condition for the cylindrical MILO using both the Brillouin flow and single particle model. The experiments show that more than 90% of shots operate at a magnetic field less than 1.3 times the Hull-cutoff magnetic field, and this magnetic field is significantly lower than the magnetic field required at the Buneman–Hartree condition. These experiments also oscillated at less current than the Hull cutoff condition on over 80% of shots, suggesting that MILOs might operate at a current lower than that expected at exactly Hull cutoff; this peculiar feature was also predicted by the theory. Particle-in-cell simulations from the improved concurrent electromagnetic particle-in-cell (ICEPIC) and CST codes are detailed, which corroborate MILO operation at lower currents than the Hull cutoff condition. The maximum efficiency achieved in these experiments is 1%, at a resonant frequency of 1 GHz. An initial comparison of the newly developed theory against prior MILO experiments is presented.

1 May 2024 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
RRRyan Revolinsky
Ryan Revolinsky
CSChristopher Swenson
Christopher Swenson
NJNicholas Jordan
Nicholas Jordan
YLY. Y. Lau
Y. Y. Lau
RGRonald Gilgenbach
Ronald Gilgenbach
The Brillouin flow is a rectilinear, sheared electron fluid flow in a crossed electric field (E) and magnetic field (B), in the E × B direction with zero flow velocity and zero electric field at the surface with which the flow is in contact. It is broadly considered as the equilibrium electron flow in high power crossed-field devices including the magnetron and magnetically insulated transmission line oscillator. This paper provides an examination of Brillouin flow in two dimensions, in a cylindrical geometry where the anode radius changes abruptly at a single axial location, while the cathode surface has a constant radius. Our simulation confirms the proof that there is no equilibrium Brillouin flow solution for such a geometry. It further reveals that this change in the anode radius introduces novel bunching of the electrons within the Brillouin hub. This bunching occurs at low frequencies and is very pronounced if the Brillouin flow is from the small gap region to the large gap region, but is minimal if the Brillouin flow is from the large gap region to the small gap region. New insights are provided into the physical processes that initiate and sustain the bunching processes that are unique for a crossed-field diode, as compared with a non-magnetized diode. We argue that this enhanced bunching, and its concomitant formation of strong vortices, is not restricted to an abrupt change in the anode–cathode gap spacing.

29 May 2020 in Nuclear Technology
Verified
Journal Article
Closed access
PMPaul R. Miles
Paul R. Miles
JCJared A. Cook
Jared A. Cook
ZAZoey V. Angers
Zoey V. Angers
CSChristopher J. Swenson
Christopher J. Swenson
BKBrian C. Kiedrowski
Brian C. Kiedrowski
RSRalph C Smith
Ralph C Smith
Recent research has focused on the development of surrogate models for radiation source localization in a simulated urban domain. We employ the Monte Carlo N-Particle (MCNP) code to provide high-fidelity simulations of radiation transport within an urban domain. The model is constructed to employ a source location ( x , y , z ) as input and return the estimated count rate for a set of specified detector locations. Because MCNP simulations are computationally expensive, we develop efficient and accurate surrogate models of the detector responses. We construct surrogate models using Gaussian processes and neural networks that we train and verify using the MCNP simulations. The trained surrogate models provide an efficient framework for Bayesian inference and experimental design. We employ Delayed Rejection Adaptive Metropolis (DRAM), a Markov Chain Monte Carlo algorithm, to infer the location and intensity of an unknown source. The DRAM results yield a posterior probability distribution for the source’s location conditioned on the observed detector count rates. The posterior distribution exhibits regions of high and low probability within the simulated environment identifying potential source locations. In this manner, we can quantify the source location to within at least one of these regions of high probability in the considered cases. Employing these methods, we are able to reduce the space of potential source locations by at least 60%.

23 June 2023 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
RRRyan A. Revolinsky
Ryan A. Revolinsky
EGEmma N. Guerin
Emma N. Guerin
SLStephen V. Langellotti
Stephen V. Langellotti
CSChristopher J. Swenson
Christopher J. Swenson
LWLevi I. Welch
Levi I. Welch
RGRonald M. Gilgenbach
Ronald M. Gilgenbach
Magnetically insulated line oscillators (MILOs) are crossed-field devices which generate a self-induced azimuthal magnetic field via an axial current. This negates the need for external magnets, potentially increasing overall system efficiency at the expense of reduced device efficiency. This article reports the design, simulation, and experimental demonstration of a dual-frequency, harmonic MILO (HMILO), which is composed of two sequential slow wave structures (SWSs) tuned for oscillation at different frequencies, each paired with a set of choke cavities and insulated by the self-generated magnetic field of the common cathode. The two SWSs—designed for operation in $L$ -and $S$ -bands at 1 and 2 GHz, respectively—were tested independently before the HMILO experiments. Results for the $L$ -band MILO (L-MILO) were reported previously by Packard. In the experiments reported here, the isolated $S$ -band MILO (S-MILO) produced $1.1 \pm 0.7$ MW of output power at $2.076 \pm 0.005$ GHz, when supplied with 207 kV and 7.3 kA from the MELBA-C generator. Ultimately, when implementing two separate extractor configurations, the HMILO produced $12.7 \pm 7.6$ MW at $0.984 \pm 0.013$ GHz and $3.2 \pm 1.5$ MW at $2.074 \pm 0.003$ GHz. These results are compared against simulated performance in the particle-in-cell (PIC) codes CST and improved concurrent electromagnetic PIC (ICEPIC).

1 March 2025 in Physics of Plasmas
Verified
Journal Article
Open access
CSChristopher Swenson
Christopher Swenson
RRRyan Revolinsky
Ryan Revolinsky
ABAdam Brusstar
Adam Brusstar
EGEmma Guerin
Emma Guerin
NJNicholas M. Jordan
Nicholas M. Jordan
RGRonald Gilgenbach
Ronald Gilgenbach
This research examines the stability of crossed-field amplifiers (CFAs) and characterizes their different modes of operation: amplification, driven oscillation, and self-excited oscillation. The CFA used in this paper is the recirculating planar crossed-field amplifier (RPCFA), which is a high power (MW) pulsed (300 ns) amplifier that operates around 3 GHz. Initially, the RPCFA is shown to be a stable amplifier with moderate gain (5.1 dB) but by either reducing the anode–cathode (AK) gap spacing or increasing the driving current, the amplifier operation transitions from amplification to oscillation. Depending on the operating conditions, these oscillations are either driven by the input RF signal or self-excited. These self-excited oscillations can have a lower synchronization phase velocity than the maximum velocity in the electron beam, implying that slower electrons within the Brillouin hub can interact with electromagnetic modes on the RF circuit. A cold tube analysis of the RPCFA shows that the Q-factor of certain modes on the RF circuit varies significantly when the AK gap geometry of the RPCFA is altered, which leads to a discrete shift in operating frequency. The operation of the RPCFA close to Hull cutoff is found to share some key features of magnetically insulated transmission line oscillators that could also explain the dramatic frequency shift. Instantaneous phase analysis by Hilbert transforms can be used, in conjunction with the frequency and output power analysis, to determine the onset of the transition from amplification to oscillation, and to characterize the oscillation.