Luis Vargas

Luis Vargas

Auto-generated profile, based on publicly available information

Luis Vargas

Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2019 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
LVLuis Vargas
Luis Vargas
HSHenry Shin
Henry Shin
HHHe (Helen) Huang
He (Helen) Huang
YZYong Zhu
Yong Zhu
XHXiaogang Hu
Xiaogang Hu
Objective . Haptic feedback is crucial when we manipulate objects. Information pertaining to an object’s stiffness in particular can help facilitate fine motor control. In this study, we seek to determine whether objects of different stiffness levels can be recognized using haptic feedback provided by transcutaneous electrical stimulation of peripheral nerves. Approach . Using a stimulation electrode grid placed along the medial side of the upper arm, the median and ulnar nerve bundles were targeted to evoke haptic sensation on the palmar side of the hand. Stimulation current amplitude was modulated in real-time with the fingertip force recorded from a sensorized prosthetic hand. In order to evaluate which stimulation pattern was more critical, object stiffness was encoded either by the rate of change of the stimulus amplitude or the level of peak stimulus amplitude, as the prosthesis grasped the objects. Main results . Both encoding methods allowed the subjects to differentiate objects of different stiffness levels with >90% accuracy. No significant difference was observed between the two encoding methods, which indicated that both the rate of change of the stimulation amplitude and the peak stimulation amplitude could effectively provide stiffness information of the objects. Significance . The outcomes suggest that it is possible to elicit haptic sensations describing various object stiffness levels using transcutaneous nerve stimulation. The haptic feedback associated with object stiffness can facilitate object manipulation/interactions. It may also improve user experience during human–machine interactions, when object stiffness information is incorporated.

5 February 2018 in IEEE Sensors Journal
Verified
Journal Article
Open access
SYShanshan Yao
Shanshan Yao
LVLuis Vargas
Luis Vargas
XHXiaogang Hu
Xiaogang Hu
YZYong Zhu
Yong Zhu
Deficits in hand function are common in a majority of stroke survivors. Although hand performance can be routinely assessed during rehabilitation training, a lack of hand usage information during daily activities could prevent clinicians or therapists from making informative therapeutic decisions. In this paper, we demonstrated and validated the application of silver nanowire-based capacitive strain sensors for finger kinematic tracking. The fabricated strain sensors show high sensitivity (gauge factor close to one), low hysteresis, good linearity, large stretchability (150%), and skin-like mechanical property (Young's modulus of 96 kPa). All these features allow the sensors to be conformally attached onto the skin to track finger joint movement with minimal interference to daily activities. Recordings of the skin deformation from the strain sensors and joint angles from reflective markers are highly correlated (>93%) for different joint oscillation speeds in a stroke survivor and a control subject, indicating the high accuracy of the strain sensors in joint motion tracking. With the wearable silver nanowire-based strain sensors, accurate hand utility information on the impaired hand of stroke survivors can be acquired in a continuous and unobtrusive manner.

27 January 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LVLuis Vargas
Luis Vargas
GWGraham Whitehouse
Graham Whitehouse
HHHe Huang
He Huang
YZYong Zhu
Yong Zhu
XHXiaogang Hu
Xiaogang Hu
Objective: Haptic perception is critical for prosthetic users to control their prosthetic hand intuitively. In this study, we seek to evaluate the haptic perception evoked from concurrent stimulation trains through multiple channels using transcutaneous nerve stimulation. Methods: A 2 × 8 electrode grid was used to deliver current to the median and ulnar nerves in the upper arm. Different electrodes were first selected to activate the sensory axons, which can elicit sensations at different locations of the hand. Charge-balanced bipolar stimulation was then delivered to two sets of electrodes concurrently with a phase delay (dual stimulation) to determine whether the evoked sensation can be constructed from sensations of single stimulation delivered separately at different locations (single stimulation) along the electrode grid. The temporal delay between the two stimulation trains was altered to evaluate potential interference. The short-term stability of the haptic sensation within a testing session was also evaluated. Results: The evoked sensation during dual stimulation was largely a direct summation of the sensation from single stimulations. The delay between the two stimulation locations had minimal effect on the evoked sensations, which was also stable over repeated testing within a session. Conclusion: Our results indicated that the haptic sensations at different regions of the hand can be constructed by combining the response from multiple stimulation trains directly. The interference between stimulations were minimal. Significance: The outcomes will allow us to construct specific haptic sensation patterns when the prosthesis interacts with different objects, which may help improve user embodiment of the prosthesis.

27 October 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
LVLuis Vargas
Luis Vargas
HHHe Huang
He Huang
YZYong Zhu
Yong Zhu
XHXiaogang Hu
Xiaogang Hu
Haptic and proprioceptive feedback is critical for sensorimotor integration when we use our hand to perform daily tasks. Here, we evaluated how externally evoked haptic and proprioceptive feedback and myoelectric control strategies affected the recognition of object properties when participants controlled a prosthetic hand. Fingertip haptic sensation was elicited using a transcutaneous nerve stimulation grid to encode the prosthetic's fingertip forces. An array of tactors elicited patterned vibratory stimuli to encode tactile-proprioceptive kinematic information of the prosthetic finger joint. Myoelectric signals of the finger flexor and extensor were used to control the position or velocity of joint angles of the prosthesis. Participants were asked to perform object property (stiffness and size) recognition, by controlling the prosthetic hand with concurrent haptic and tactile-proprioceptive feedback. With the evoked feedback, intact and amputee participants recognized the object stiffness and size at success rates ranging from 50% to 100% in both position and velocity control with no significant difference across control schemes. Our findings show that evoked somatosensory feedback in a non-invasive manner can facilitate closed-loop control of the prosthetic hand and allowed for simultaneous recognition of different object properties. The outcomes can facilitate our understanding on the role of sensory feedback during bidirectional human-machine interactions, which can potentially promote user experience in object interactions using prosthetic hands.

16 January 2020 in IEEE Transactions on Haptics
Verified
Journal Article
Closed access
LVLuis Vargas
Luis Vargas
HHHe Huang
He Huang
YZYong Zhu
Yong Zhu
XHXiaogang Hu
Xiaogang Hu
Tactile feedback is critical for distinguishing different object properties. In this article, we determined if tactile feedback evoked by transcutaneous nerve stimulation can be used to detect objects of different shape and surface topology. To evoke tactile sensation at different fingers, a 2x8 electrode grid was placed along the subject's upper arm, and two concurrent electrical stimulation trains targeted the median and ulnar nerve bundles, which evoked individually modulated sensations at different fingers. Fingertip forces of the prosthetic hand were transformed to stimulation current amplitude. Object shape was encoded based on finger-object contact timing. Surface topology represented by ridge height and spacing was encoded through current amplitude and stimulation time interval, respectively. The elicited sensation allowed subjects to determine object shape with success rates >84%. Surface topology recognition resulted in success rates >81%. Our findings suggest that tactile feedback evoked from transcutaneous nerve stimulation allows the recognition of object shape and surface topology. The ability to recognize these properties may help improve object manipulation and promote fine control of a prosthetic hand.

8 August 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
LVLuis Vargas
Luis Vargas
HHHe Huang
He Huang
YZYong Zhu
Yong Zhu
DKDerek Kamper
Derek Kamper
XHXiaogang Hu
Xiaogang Hu
Tactile feedback in the hand is essential for interaction with objects. Here, we evaluated how artificial tactile sensation affected the recognition of object properties using a myoelectrically controlled prosthetic hand. Electromyogram signals from the flexor and extensor finger muscles were used to continuously control either prosthetic joint velocity or position. Participants grasped objects of varying shape or size using the prosthetic hand. Tactile feedback was evoked by transcutaneous nerve stimulation along the participant's upper arm and modulated based on the prosthetic-object contact force. Multi-channel electrical stimulation targeted the median and ulnar nerve bundles to produce resembled tactile sensations at distinct hand regions. The results showed that participants could gauge the onset timing of tactile feedback to discern object shape and size. We also found that the position-controller led to a greater recognition accuracy of object size compared with velocity-control, potentially due to supplemental joint position information from muscle activation level. Our findings demonstrate that non-invasive tactile feedback can enable effective object shape and size recognition during prosthetic control. The evaluation of tactile feedback across myoelectric controllers can help understand the interplay between sensory and motor pathways involved in the control of assistive devices.