Henry Shin

Henry Shin

Auto-generated profile, based on publicly available information

Henry Shin

School of Rehabilitation Sciences and Engineering, University of Health and Rehabilitation Sciences, Qingdao, Shandong, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2018 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
HSHenry Shin
Henry Shin
ZWZach Watkins
Zach Watkins
HHHe (Helen) Huang
He (Helen) Huang
YZYong Zhu
Yong Zhu
XHXiaogang Hu
Xiaogang Hu
Objective . Haptic perception of a prosthetic limb or hand is a crucial, but often unmet, need which impacts the utility of the prostheses. In this study, we seek to evaluate the feasibility of a non-invasive transcutaneous nerve stimulation method in generating haptic feedback in a transradial amputee subject as well as intact able-bodied subjects. Approach . An electrode grid was placed on the skin along the medial side of the upper arm beneath the short head of the biceps brachii, in proximity to the median and ulnar nerves. Varying stimulation patterns were delivered to different electrode pairs, in order to emulate different types of sensations (Single Tap, Press-and-Hold, Double Tap) at different regions of the hand. Subjects then reported the magnitude of sensation by pressing on a force transducer to transform the qualitative haptic perception into a quantitative measurement. Main results . Altering current stimulations through electrode pairs on the grid resulted in repeatable alterations in the percept regions of the hand. Most subjects reported spatial coverage of individual fingers or phalanges, which can resemble the whole hand through different pairs of stimulation electrodes. The different stimulation patterns were also differentiable by all subjects. The amputee subject also reported haptic sensations similar to the able-bodied subjects. Significance . Our findings demonstrated the capabilities of our transcutaneous stimulation method. Subjects were able to perceive spatially distinct sensations with graded magnitudes that emulated tapping and holding sensation in their hands. The elicitation of haptic sensations in the phantom hand of an amputee is a significant step in the development of our stimulation method, and provides insight into the future adaptation and implementation of prostheses with non-invasive sensory feedback to the users.

5 December 2019 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
LVLuis Vargas
Luis Vargas
HSHenry Shin
Henry Shin
HHHe (Helen) Huang
He (Helen) Huang
YZYong Zhu
Yong Zhu
XHXiaogang Hu
Xiaogang Hu
Objective . Haptic feedback is crucial when we manipulate objects. Information pertaining to an object’s stiffness in particular can help facilitate fine motor control. In this study, we seek to determine whether objects of different stiffness levels can be recognized using haptic feedback provided by transcutaneous electrical stimulation of peripheral nerves. Approach . Using a stimulation electrode grid placed along the medial side of the upper arm, the median and ulnar nerve bundles were targeted to evoke haptic sensation on the palmar side of the hand. Stimulation current amplitude was modulated in real-time with the fingertip force recorded from a sensorized prosthetic hand. In order to evaluate which stimulation pattern was more critical, object stiffness was encoded either by the rate of change of the stimulus amplitude or the level of peak stimulus amplitude, as the prosthesis grasped the objects. Main results . Both encoding methods allowed the subjects to differentiate objects of different stiffness levels with >90% accuracy. No significant difference was observed between the two encoding methods, which indicated that both the rate of change of the stimulation amplitude and the peak stimulation amplitude could effectively provide stiffness information of the objects. Significance . The outcomes suggest that it is possible to elicit haptic sensations describing various object stiffness levels using transcutaneous nerve stimulation. The haptic feedback associated with object stiffness can facilitate object manipulation/interactions. It may also improve user experience during human–machine interactions, when object stiffness information is incorporated.

29 November 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HSHenry Shin
Henry Shin
ZWZach Watkins
Zach Watkins
XHXiaogang Hu
Xiaogang Hu
Various neurological conditions, such as stroke or spinal cord injury, result in an impaired control of the hand. One method of restoring this impairment is through functional electrical stimulation (FES). However, traditional FES techniques often lead to quick fatigue and unnatural ballistic movements. In this study, we sought to explore the capabilities of a non-invasive proximal nerve stimulation technique in eliciting various hand grasp patterns. The ulnar and median nerves proximal to the elbow joint were activated transcutanously using a programmable stimulator, and the resultant finger flexion joint angles were recorded using a motion capture system. The individual finger motions averaged across the three joints were analyzed using a cluster analysis, in order to classify the different hand grasp patterns. With low current intensity (<5 mA and 100 µs pulse width) stimulation, our results show that all of our subjects demonstrated a variety of consistent hand grasp patterns including single finger movement and coordinated multi-finger movements. This study provides initial evidence on the feasibility of a proximal nerve stimulation technique in controlling a variety of finger movements and grasp patterns. Our approach could also be developed into a rehabilitative/assistive tool that can result in flexible movements of the fingers.

26 May 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
Xiaoyan LiXiaoyan Li
Xiaoyan Li
Le LiLe Li
Le Li
HSHenry Shin
Henry Shin
SLSheng Li
Sheng Li
Ping ZhouPing Zhou
Ping Zhou
Electrical impedance myography (EIM) was used to assess the paretic muscle intrinsic electrical properties post stroke. Twenty-seven subjects with chronic hemiparesis participated in this study. Muscle impedance was measured by applying high-frequency, low-intensity alternating current to biceps brachii muscles. Major EIM parameters, resistance (R), reactance (X), phase angle (8), and electrical anisotropy ratios (AR) of the three parameters, were examined at 50 kHz. Statistical analysis demonstrated significant reduction of reactance, phase angle, AR of resistance, and AR of reactance in the paretic muscle compared with the contralateral side (Paretic X: 6.16 ± 0.55 Q, contralateral X: 7.62 ± 0.46 Ω, and p <; 0.001; Paretic θ: 10.97 ± 0.84°, contralateral θ: 14.5 ± 0.82°, and p <; 0.001; Paretic AR of R: 0.969 ± 0.013, contralateral AR of R: 1.008 ± 0.011, and p <; 0.02; and Paretic AR of X: 0.981 ± 0.066, contralateral AR of X: 1.114 ± 0.041, and p <; 0.02). Correlation analysis, however, did not show any significant-relationship between EIM parameters and clinical assessments. Findings of this paper indicated significant changes in the muscular intrinsic electrical properties after stroke, possibly related to structural modifications induced by loss of muscle fibers or fat infiltration as well as changes in the quality of cell membranes post stroke.

17 September 2018 in Journal of Neural Engineering
Verified
Journal Article
Closed access
HSHenry Shin
Henry Shin
RCRyan Chen
Ryan Chen
XHXiaogang Hu
Xiaogang Hu
Objective . Weakness of the hand is a major impairment which limits independent living. Neuromuscular electrical stimulation (NMES) is a common approach to help restore muscle strength. Traditional NMES directly over the muscle often leads to a rapid onset of muscle fatigue. In this study, we investigated the force sustainability of finger flexor muscles using a transcutaneous nerve stimulation approach. Approach . Finger flexion forces and high-density electromyogram (HD EMG) signals were obtained while electrical stimulation was applied to the ulnar and median nerve bundles through a stimulation grid on the proximal arm segment. Stimulation was also applied to the finger flexor muscle belly targeting the motor point, serving as a control condition. The force produced from the two stimulation approaches were initially matched, and muscle fatigue was subsequently induced with 5 min of continuous stimulation. The rate of decay of the force and EMG amplitude were quantified, and the spatial distribution of the muscle activation during the sustained contraction was also evaluated. Main results . The proximal nerve stimulation approach induced a slower decay in both force and EMG, compared with the stimulation at the motor point. The spatial distribution of the elicited muscle activation showed that the proximal nerve stimulation led to a distributed activation across the intrinsic and extrinsic finger flexor muscles and also activated a wider area within the extrinsic muscle. Significance . Our findings demonstrated that the stimulation of the proximal nerve bundles can elicit sustained force output and delayed decrease in the rate of force decline. This is potentially due to a spatially distributed activation of the muscle fibers, compared with the traditional motor point stimulation. Future development of our nerve stimulation approach may enable prolonged usage during rehabilitation or assistance for better functional outcomes.

1 December 2020 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
HSHenry Shin
Henry Shin
MHMarwan A. Hawari
Marwan A. Hawari
XHXiaogang Hu
Xiaogang Hu
Objective: Functional electrical stimulation (FES) is a common technique to elicit muscle contraction and help improve muscle strength. Traditional FES over the muscle belly typically only activates superficial muscle regions. In the case of hand FES, this prevents the activation of the deeper flexor muscles which control the distal finger joints. Here, we evaluated whether an alternative transcutaneous nerve-bundle stimulation approach can activate both superficial and deep extrinsic finger flexors using a high-density stimulation grid. Methods: Transverse ultrasound of the forearm muscles was used to obtain cross-sectional images of the underlying finger flexors during stimulated finger flexions and kinematically-matched voluntary motions. Finger kinematics were recorded, and an image registration method was used to capture the large deformation of the muscle regions during each flexion. This deformation was used as a surrogate measure of the contraction of muscle tissue, and the regions of expanding tissue can identify activated muscles. Results: The nerve-bundle stimulation elicited contractions in the superficial and deep finger flexors. Both separate and concurrent activation of these two muscles were observed. Joint kinematics of the fingers also matched the expected regions of muscle contractions. Conclusions: Our results showed that the nerve-bundle stimulation technique can activate the deep extrinsic finger flexors, which are typically not accessible via traditional surface FES. Significance: Our nerve-bundle stimulation method enables us to produce the full range of motion of different joints necessary for various functional grasps, which could benefit future neuroprosthetic applications.